• 제목/요약/키워드: Power plant control

검색결과 1,504건 처리시간 0.03초

Development of a Power Plant Simulation Tool with GUI based on General Purpose Design Software

  • Kim Dong Wook;Youn Cheong;Cho Byung-Hak;Son Gihun
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권3호
    • /
    • pp.493-501
    • /
    • 2005
  • A power plant simulation tool ('PowerSim') has been developed with 10 years experience from the development of a plant simulator for efficient modeling of a power plant. PowerSim is the first developed tool in Korea for plant simulation with various plant component models, instructor station function and the Graphic Model Builder (GMB). PowerSim is composed of a graphic editor using general purpose design software, a netlist converter, component models, the scheduler, Instructor Station and an executive. The graphic editor generates a netlist that shows the connection status of the various plant components from the Simdiagram, which is drawn by Icon Drag method supported by GUI environment of the PowerSim. Netlist Converter normalizes the connection status of the components. Scheduler makes scheduling for the execution of the device models according to the netlist. Therefore, the user makes Simdiagram based on the plant Pipe and Instrument Drawing (P&ID) and inputs the plant data for automatic simulating execution. This paper introduces Graphic Model Builder (GMB), instructor station, executive and the detailed introduction of thermal-hydraulic modeling. This paper will also introduce basic ideas on how the simulation Diagram, based on netlist generated from general purpose design software, is made and how the system is organized. The developed tool has been verified through the simulation of a real power plant.

전력설비 대용량 보일러 통풍기 날개각 제어 작동기 모델링 (Modelling of Power Plant Fan Pitch Blade Control Actuator)

  • 허준영;손태하
    • 유공압시스템학회논문집
    • /
    • 제4권2호
    • /
    • pp.28-33
    • /
    • 2007
  • In the power plant facility which use soft coal as a power source the fan pitch blade control hydraulic actuator is used to control the inlet and outlet gas to regulate the internal pressure of the furnace and control the frequence. Sometimes malfunctions of this equipment lead to the decline of boiler thermal efficiency and unexpected power plant trip. In order to localize the fan pitch blade control hydraulic actuator specially for the 500MW large scale boiler, Analysis and modelling of the system is carried out mathematically. The responses of the system are examined by using matlab simulation fur the variation of the major parameters in view of reverse engineering. Consequently the validity of the established parameters are examined.

  • PDF

하동 화력 발전소 전범위 시뮬레이터 개발 (A Full Scale Fossil Power Plant Simulator For Hadong)

  • 김성호;김종현;조창호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.204-204
    • /
    • 2000
  • This paper describes the development of training simulator for Hadong fossil Power Plant. The simulator was developed to train operator, test new control Logic and evaluate alternative operating procedure for expert engineer of control system. The most control logics such as Siemens TELEPERM ME and GE Mark V are translated directly from microprocessors. Those HMI are also directly emulated. The simulation was performed by ProTRAX modeling software. The paper discusses the configuration of simulator and the simulation results of 30%, 50%, 75% and 100% normal rate load test.

  • PDF

원자력 발전소 제어 계통을 위한 통신망의 해석과 사례 연구 (Analysis of a Communication Network for Control Systems in Nuclear Power Plants and a Case Study)

  • 이서우;윤명현;문홍주;신창훈;이병윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.1013-1016
    • /
    • 1999
  • In this paper, a real-time communication method using a PICNET-NP(Plant Instrumentation and Control Network for Nuclear Power plant) is proposed with an analysis of the control network requirements of DCS (Distributed Control System) in nuclear power plants. The method satisfies deadline in case of worst data traffics by considering aperiodic and periodic real-time data and others. In addition, the method was used to analyze the data characteristics of the DCS in existing nuclear power plant. The result shows that use of this method meets the response time requirement(100ms)

  • PDF

원자력발전소 직류전원계통용 축전지 성능시험 분석 (Analysis of Battery Performance Test for DC Power System in Nuclear Power Plant)

  • 김대식;차한주
    • 전기학회논문지P
    • /
    • 제63권2호
    • /
    • pp.61-68
    • /
    • 2014
  • Function of battery bank stores energy for DC load in general, and DC power system of the nuclear power plant is used to supply DC loads for safety- featured instrumentation and control such as inverter, class 1E power system control and indication, and station annunciation. Class 1E DC power system must provide a power for the design basis accident conditions, and adequate capacity must be available during loss of AC power and subsequent safe shutdown of the plant. In present, batteries of Class 1E DC power system of the nuclear power plant uses lead-acid batteries. Class 1E batteries of nuclear power plants in Korea are summarized in terms of specification, such as capacity, discharge rate, bank configuration and discharge end voltage, etc. This paper summarizes standards of determining battery size for the nuclear power plant, and analyzes duty cycle for the class 1E DC power system of nuclear power plant. Then, battery cell size is calculated as 2613Ah according to the standard. In addition, this paper analyzes performance test results during past 13 years and shows performance degradation in the battery bank. Performance tests in 2001 and 2005 represent that entire battery cells do not reach the discharge-end voltage. Howeyer, the discharge-end voltage is reached in 14.7% of channel A (17 EA), 13.8% of channel B (16 EA), 5.2% of channel C (6 EA) and 16.4% of channel D (19 EA) at 2011 performance test. Based on the performance test results analysis and size calculation, battery capacity and degradation by age in Korearn nuclear power plant is discussed and would be used for new design.

석탄화력 발전소의 LOAD RUN BACK에 관한 연구 (A Study on the Load Run Back Control of a Coal Fired Power Plant.)

  • 송성일;황재호;박형구;김흥록
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.94-97
    • /
    • 1989
  • This work describes the imortance of the load run back control of a thermal power plant which has a serious effect on a power system, and shows the load run back tests results which was carried out at BORONG Thermal Power Plant, finally suggests what control circuits should be modified in the plant control system in order to prevent plant trip in case of auxiliary machine failure.

  • PDF

운전데이터에 의한 증기터빈 발전소의 부하제어에 관한 고찰 (A Study on Load Control in a Steam Turbine Power Plant using Acquired Data)

  • 우주희;최인규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.749-751
    • /
    • 1999
  • We acquired operating data in an existing steam turbine power plant using analog control system to investigate operation characteristics. We analyzed a load control logic to develop a digital turbine control system. The load control logic is constituted of load target, load reference, loading rate, load limit and admission mode transfer of valve. The result of this paper is utilized to implement a digital turbine control system.

  • PDF

화력발전소의 과열기증기의 온도제어 (Temperature Control of Superheater Steam in Thermal Power Plant)

  • 신휘범;이순영
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.2006-2011
    • /
    • 2010
  • The superheater in the thermal power plant makes the wet steam into the dry steam with high temperature and high pressure by using the boiler heat. The dry steam pressure rotates the turbine-generator system. The efficiency and life time of the boiler heavily depends on the steam temperature regulation. The steam temperature can be deviated from the reference by the MW demand of the power plant. It is therefore required that the PI(proportional-integral) controller should be robust against the disturbance such as the MW demand. In this paper, the PI controller with the integral state predictor is proposed and applied to regulate the steam temperature of the superheater, and it is compared with the conventional PI controller operated in the thermal power plant in view of control performance.

발전소 보일러 제어기에 대한 내고장성 제어 시스템의 적용에 관한 연구 (A Case Study on Application of Fault Tolerant Control System to Boiler Controller in Power Plant)

  • 조영조;문봉채;김병국
    • 대한전자공학회논문지
    • /
    • 제27권1호
    • /
    • pp.10-19
    • /
    • 1990
  • A fault tolerant control system, in which a digital back-up controller system is added on the existing analog control system, is developed for enhancing reliability of boiler control system in power plant. The digital back-up controller system(DBCS) has a multi-processor structure with capabilities of fault diagnosis, back-up control, self test, and graphic monitoring. Specifically, switching mechanism composed of expandable modules is designed so that back-up controller takes over any faulty control loops and the number of back-up control loops is determined as that of simultaneous faults. A process simulator that simulates the boiler analog control system is developed for safety test and performance evaluation prior to real plant application. DBCS is installed at the Ulsan thermal power plant, and fault tolerant control performance is assured under the faults that some controller modules are pulled out.

  • PDF

원자력발전소 디젤발전기 디지털 다중화 여자시스템 개발 및 적용 (The Development of Digital Excitation Control System for Diesel Generator of Nuclear Power Plant and Its Application)

  • 이주현;임익헌;신만수;정태원
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1449-1455
    • /
    • 2010
  • The excitation control system of an emergency diesel generator is classified as a kind of safety-related system. Compared with other control systems in a power plant, this system is required to be more reliable and have better performance. In this paper, the digital multi-redundant excitation system for a diesel generator was proposed. The signal processing system of the proposed system makes high speed signal processing and arithmetic in excitation control possible. The improved soft start algorithm and multiple PI parameters adaptation considering the diesel generator characteristics were implemented in the proposed system. The developed system was applied to a nuclear power plant successfully.