• Title/Summary/Keyword: Power of a circle

Search Result 106, Processing Time 0.022 seconds

Diameter of the retinal blur circle in a artificial hypermetropia (인워적 원시에 따른 망막에서 착란원 크기)

  • Choi, Woon Sang;Kim, Yoon-Kyung;Oh, Heung Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.145-149
    • /
    • 2005
  • In a artificial hypermetropia with the accommodative response, we investigated a diameter of blur circle as a function of test lens refractive power. In a schematic eye model of the hypermetropia, the second focal length along to accommodated power of the crystal lens are calculated as a function of test lens power and, also distance between the retina and exit pupil are calculated as a function of accommodated power. As these results are compared, the size of blur circle on the retina are obtained.

  • PDF

HYPERBOLIC AND SPHERICAL POWER OF A CIRCLE

  • Young Wook Kim;Sung-Eun Koh;Hyung Yong Lee;Heayong Shin;Seong-Deog Yang
    • Bulletin of the Korean Mathematical Society
    • /
    • v.60 no.2
    • /
    • pp.507-514
    • /
    • 2023
  • Suppose that a line passing through a given point P intersects a given circle 𝓒 at Q and R in the Euclidean plane. It is well known that |PQ||P R| is independent of the choice of the line as long as the line meets the circle at two points. It is also known that similar properties hold in the 2-sphere and in the hyperbolic plane. New proofs for the similar properties in the 2-sphere and in the hyperbolic plane are given.

The Developmental Process of Blur Circle along to the Variation of a Refractive Power for Hyperopia (원시에서 교정굴절력변화에 따른 착란원 크기)

  • Choi, Woon Sang;Jung, Soo-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.155-157
    • /
    • 2000
  • A variable process of blur circle is calculated for a artificial hyperopia. The calculation is used to the value of Gullstrand's theoretical eye and a method of geometrical optics. The theoretical eye simplified a entrance pupil and the retina. Ophthalmic lens and eye changed a equivalent lens. Refractive power of a equivalent lens is converted to focal length within theoretical eye, and this is calculated about relation of a blur circle on the retina and ophthalmic lens.

  • PDF

A Study on the Relationship between the Disc of Least Confusion and Corrected Vision of Astigmatism (난시안의 최소착락원과 교정시력과의 관계 연구)

  • Kim, Jung-Hee;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.51-57
    • /
    • 2008
  • Purpose: This study has been conducted to know how the size and position of the circle of least confusion has an influence on the vision for minimization of asthenopia when astigmatism is corrected and appropriated prescription to provided clear vision life. Methods: The method of the study has been worked on 68 students (136 eyes) of man and woman enrolled in university of Gyeong-gi-do aged 20 to 40, who have myopic astigmatism in order to know how the corrected vision changes according to the size and position of the circle of least confusion of astigmatism, the vision has been tested by giving the vision whose astigmatic power of 0.25D and 0.50D was just reduced, low correcting the astigmatic power into 0.50D, and at the same time inserting additionally spherical power -0.25D, all under a condition that the corrected vision after completely corrected astigmatism, and the axis of astigmatism was not changed. Results: The average vision was 1.047 when the astigmatic power was fully corrected, and in low correction of 0.25D, it was 0.914, and in low correction of 0.50, it was 0.772. It has been learned that the bigger the circle of least confusion was the bigger the range of vision reduction and the corrected vision in astigmatism has correlation with the size of the circle of least confusion. It has been examined that the average vision according to position of the circle of least confusion in astigmatism was 1.047 when the astigmatic power was completely corrected and focused on the retina with state of point, and in case that the astigmatic power was 0.50D of state of low correction, that is, the circle of least confusion was focused before retina, it was 0.828, and it was also 0.826 when the astigmatic power is low corrected with 0.50D and the circle of least confusion was focused on the retina. Explained briefly, It has been examined that in case that the state of low correction of the astigmatic power was same, the vision reduction was less in the image of the circle of least confusion focused upon the retina than in the image of its being focused before the retina. Conclusions: In case that the refractive power of cylindrical lens is reduced in test of wearability in astigmatism, there needs surely an adjustment of spherical lens that can place the circle of least confusion on the retina.

  • PDF

Relationship of Blur Circle and Height of the Retinal Image about visual Acuity in a Artificial Myopia (인위적 근시에서 망막상의 크기와 시력과의 관계)

  • Choi, Woon Sang;Sohn, Sung Eun;Kim, Jin Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.21-23
    • /
    • 2002
  • Compared visual acuity that is measured in a artificial myopia with the numerical calculation. Calculation included image's height as well as blur circle that is formed to retina. The blur circle calculated in geometrical optics model, and height of retinal image calculated by refractive power and visual acuity that is measured in a artificial myopia. Define this result as "blur ratio" about blur circle and height of retinal image, and investigated blur ratio relationship about visual acuity in a artificial myopia.

  • PDF

P-Q Circle Diagram Based Parameter Measurement for Permanent Magnet Synchronous Motor Including Iron Loss

  • Urasaki, Naomitsu;Senjyu, Tomonobu;Uezato, Katsumi
    • Journal of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.55-61
    • /
    • 2003
  • This paper presents parameter measurement for permanent magnet synchronous motors based on the P-Q circle diagram. Three electrical parameters of permanent magnet synchronous motors, i.e., the equivalent iron loss resistance, armature inductance, and electrical motive force (emf) coefficient are simultaneously measured. The advantages of this method are that it can be implemented under constant excitation and it dispenses with the generating test for the emf coefficient. The proposed method is applied to a 160w permanent magnet synchronous motor, and then the measurement results are analyzed.

A Study on the Direction finding of Drones Using Apollonius Circle Technique (Apollonius Circle 기법을 활용한 드론 방향탐지 연구)

  • Choi, Hong-Rak;Jeong, Won-Ho;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.3
    • /
    • pp.83-92
    • /
    • 2018
  • This paper uses the Apollonius Circle technique to estimate the position of a target that generates a specific signal by using a drone, which is rapidly becoming a rapidly expanding industry. The existing direction finding method is performed through the vehicle on the ground or installed the antenna at a high position to detect the position of the target. However, the conventional direction finding method is difficult to configure the reception environment of the LOS signal, It is difficult. However, the direction finding using the drone is easy to construct and measure the LOS signal receiving environment using the drone flying at high altitude. In this study, we use the 3D 800MHz Path-Loss Model to reconstruct the signal by using the measurement data of the ground direction finding, reconstruct the signal by using the 3-D 800MHz Path-Loss Model, and use the Apollonius Circle method to estimate the position of the target. A simulation was performed to estimate the position of the target. Simulation was performed to determine the target position estimation performance by configuring the ground direction finding and the dron direction finding.

Investigation about the Wear Characteristics of Nylon Pinions Against Steel Gears by SEM (SEM을 이용한 나일론피니언의 마멸특성 고찰)

  • Kim, Choong-Hyun;Ahn, Hyo-Sok;Chong, Tae-Hyong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.6
    • /
    • pp.1159-1168
    • /
    • 2002
  • Power-transmission Nylon pinions against steel gears fur different pitch line velocities was studied with a power circulating gear test rig under unlubricated condition by SEM(Scanning Electron Microscope). The wear characteristics of Nylon pinions varied significantly with the pitch line velocity and applied load. Wear occurred most severely at the regions including pitch circle and root circle of Nylon pinions. It is confirmed that Nylon pinions are able to be used fer power-transmission under limited conditions.

A Study on Competitive Power Comparison and Strategy Collaboration of the Biggest Three Ports of the Economic Circle Around Bohai

  • Meng, Qing-Chun;Sun, Han-Gao
    • Proceedings of the Korea Port Economic Association Conference
    • /
    • 2007.07a
    • /
    • pp.441-455
    • /
    • 2007
  • Based on the fact that Qingdao port, Tianjin port and Dalian port of the economic circle around Bohai have been the three islands of stability through long-term competition, this paper conducts a system study on the competitive powers of the three ports through AHP model on the analysis of current status of the three ports, and probes deeply into the outer factors and the inner factors affecting on the competitive advantage, and points out the existing problems in competition. We think that the three ports must compete orderly and collaborate closely, and give the forms and approaches developing strategy collaboration in order to obtain an advantageous position in Northeast Asia and improve the international competitive power.

  • PDF

Changes of Corrective Astigmatism Values Depending on Position of Circle of Least Confusion in Astigmatic Refining Test Using Cross Cylinder (크로스실린더를 이용한 난시정밀검사에서 검사 전 최소착란원 위치에 따른 난시교정값의 변화)

  • Kim, Sang-Yeob;Lee, Min Jae;Lee, Kang Cheon;Lee, Tae Hui;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.349-354
    • /
    • 2015
  • Purpose: To investigate the changes of corrective values of astigmatism caused by the position of circle of least confusion on retina in refining astigmatic test using cross cylinder. Methods: 62 subjects (115 eyes) aged $22.24{\pm}2.48$ years participated for this study. After astigmatic test using a radial chart, refining test was performed using a cross cylinder in a condition of maximum plus to maximum visual acuity (MPMVA). Astigmatic refining test was repeatedly performed in each condition of which S+0.75 D, S+0.50 D, S+0.25 D, S-0.25 D, S-0.50 D, and S-0.75 D are added to spherical lenses of MPMVA. The measured values were compared with the values in MPMVA condition. Results: As compared with values in condition of MPMVA, change of astigmatic axis was increased with add the power of (+) spherical lenses and (-) spherical lenses. In same spherical condition, change of astigmatic axis was decreased with increment of astigmatic power (p<0.05). The corrective power of astigmatism was reduced with increment of (+) spherical lenses (p<0.05), and was raised with increment of (-) spherical lenses compared with the power in MPMVA condition. In case of adding (+) spherical lenses, difference of astigmatic power increased with increment of corrective astigmatism power in same test condition. Conclusions: In order to obtain a proper values for corrective astigmatism, position of circle of least confusion should be accurately adjusted before the performing an astigmatism's refining test.