• Title/Summary/Keyword: Power measurements

Search Result 1,582, Processing Time 0.031 seconds

Minimizing the power consumption of ZigBee RF4CE Certified Platform

  • Jung, Taek-Soo;Kim, Jung-Won
    • Journal of IKEEE
    • /
    • v.15 no.4
    • /
    • pp.287-292
    • /
    • 2011
  • The RF4Control stack is used with microcontrollers and IEEE(R) 802.15.4 transceivers. This paper explains the setup and power consumption measurements for the transceiver based remote controller and target node. It is assumed the reader of this paper has knowledge about RF4CE. The current consumption measurements are made using the ZigBee Platform included with the RF4Control stack. he current consumption measurements are presented, and battery life time is calculated for an remote controller. Note that the results presented in this paper are intended as a guideline only. A variety of factors will influence the battery life calculation and final measurements and calculations should be performed on ZigBee RF4CE Certified Platform.

Development of On line Diagnosis System for Generator (발전기 운전중 종합 진단시스템 개발)

  • Lee, Young-Jun;Kong, Tae-Sik;Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.975-977
    • /
    • 2005
  • The generator on-line diagnosis system has been developed. This system monitor the insulation condition of stator winding by on-line measurements of partial discharge and the shorted-turn condition of rotor winding by on-line measurements of slot leakage flux. Sensor, such as SSC(Stator Slot Coupler) and flux probe are used for generator on-line diagnosis.

  • PDF

Development of the precision AC/DC power measuring system on the basis of thermal converters (열전형변환기를 사용한 정밀 교류직류전력측정장치 개발)

  • 박영태;장석명
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.1
    • /
    • pp.9-13
    • /
    • 1996
  • The high precision of electrical power and energy measurements with wide range of frequency and power factor can be achieved by using the thermo-electrical power comparators. The paper describes the development of a precision power measuring system by using a ac/dc power comparator for measurement of power. Based on a thermal principle, the instrument performs ac-dc transfer for ac power measurements in the range of currents from 0 to 5 $A_{ms}$ , voltages from 0 to 240 $V_{ms}$ , power factors from 0 to 1 and frequencies from 0 to 1000 Hz. Two thermal converters with two heater are used in the functional element of the comparators. The ac-dc transfer accuracy is better than 20 ppm at unity power factor and better than 50 ppm at 0.5 power factor. (author). 8 refs., 5 figs., 3 tabs.

  • PDF

Thermoelectric Power (TEP) Measurement To Assess Weld Integrity of HSLA Steel Welds (열기전력 측정을 이용한 고장력강 용접부의 미세조직의 고찰에 관한 연구)

  • Park, Yeong-Do
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.144-146
    • /
    • 2005
  • Measurements of Thermoelectric power (TEP) were used to evaluate microstructural analysis in HSLA steel weldments. The measurements of TEP for weld microstructure across weldment have shown good correlation with hardness profile. The different TEP values indicated that changes in weld microstructure can be correlated with TEP values measured.

  • PDF

Estimation of Power System Parameters using Synchronized Phaser Measurements (동기 페이저 측정치를 이용한 전력계통 매개변수 추정)

  • Song, Shi-Cheol;Cho, Ki-Seon;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.80-84
    • /
    • 2000
  • Network parameters in power systems are indispensable for all of power system engineering studies, including the power flow calculation and the state estimation. The network parameters required for the studios, in general, are estimated by using several estimation techniques, since it Is very difficult to measure. To improve the estimation accuracy of the network parameters, this paper adopt the synchronized phasor measurements which are acquired from the Phasor Measurement Unit with built-in GPS receiver. In this paper, the parameter estimation problem is formulated with over-determined nonlinear measurement equations and solved with Newton-Raphson method and pseudo-inverse. The effectiveness of the proposed parameter estimation with the synchronized phasor measurements is verified through some case studies with IEEE sample system. The results are very promising.

  • PDF

Imperfect Competition and Productivity: Korean Fossil-fueled Power Generation Sector (발전부문의 불완전경쟁과 생산성 변화)

  • Kwon, Oh-Sang;Park, Hojeong
    • Environmental and Resource Economics Review
    • /
    • v.19 no.1
    • /
    • pp.3-21
    • /
    • 2010
  • By the significant structural change in 1999, a partial privatization has occurred in Korean fossil-fuel power generation sector. Under the current price scheme wholesale electricity price is dependent on output size, and hence, may not satisfy the assumption of price-taking producers. The purpose of our study is constructing the productivity change measurements of Korean power generation sector taking into account possibly imperfect competition and variable returns to scale. Our approach based on Harrison (1994) and Levinsohn (1993) derives the plant-level productivity measurements of the period between 2001 and 2007, as well as the measurements of mark-ups and returns to scale. It is shown that the mark-up size is dependent on the plants' fuel type and is decreasing over time. Allowing for imperfect competition and variable returns to scale adjusts the productivity measurements substantially.

  • PDF

Power Savings of a Refrigerator with 3D-PTV Measurements (3D-PTV에 의한 냉장고 소비전력 저감)

  • Hwang Tae-Gyu;Doh Deog-Hee;Park Seong-Ryong;Bang Yoon-Seok;Yang Min-Cheol;Jang Gyu-Seob;Kim Suk-Roh;Lee Yeon-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1145-1153
    • /
    • 2005
  • 3D-PTV measurement has been carried out for the inner flows of a refrigerator. To visualize the air flows three-dimensionally, a helium bubble generator has been used for the 3D-PTV measurements. Three-dimensional flow field of the refrigerator's compartments have been reconstructed by the results obtained by the 3D-PTV Measurements on the electric power-consumption was also carried out in order to evaluate the improvements of the flow characteristics. It was verified that $3\%$ of power consumption was saved by improving the flow passages and characteristics.

A Study on the Harmonics and Flicker Measurements and Analysis of the Grid Connected Photovoltaic Power System (전력계통 연계형 태양광 발전시스템의 고조파 및 플리커의 측정 및 분석에 관한 연구)

  • Kim, Kyung-Chul;Kim, Yong-Kwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.5
    • /
    • pp.48-57
    • /
    • 2012
  • This paper analyzes the characteristic of gird connected photovoltaic power generation system which is available to connect the utility. Renewable energy photovoltaic power system has been linked to the system to analyze the impact of photovoltaic system. It is measured that power data for the Grid connected photovoltaic power plant with instantaneous measuring and 3-sec measuring for 7 days. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. A cumulative probability approach is the most commonly used method to solve time varying harmonics. So, it is used 50[%] cumulative probability approach. This paper provides an in depth analysis on power quality field measurement of the Grid connected photovoltaic power plant.

Neural Nerwork Application to Bad Data Detection in Power Systems (전력계토의 불량데이타 검출에서의 신경회로망 응용에 관한 연구)

  • 박준호;이화석
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.6
    • /
    • pp.877-884
    • /
    • 1994
  • In the power system state estimation, the J(x)-index test and normalized residuals ${\gamma}$S1NT have been the presence of bad measurements and identify their location. But, these methods require the complete re-estimation of system states whenever bad data is identified. This paper presents back-propagation neural network medel using autoregressive filter for identification of bad measurements. The performances of neural network method are compared with those of conventional mehtods and simulation results show the geed performance in the bad data identification based on the neural network under sample power system.

A Study on the Establishment of Insulation Diagnosis Cycle for High Voltage Rotating Machine (고압회전기 절연진단 주기 설정에 관한 연구)

  • Lee, Young-Jun;Kim, Hee-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1939-1941
    • /
    • 2000
  • Nondestructive and destructuve insulation tests were performed the high voltage rotating machine in the local thermal power plants. Nondestructive tests include measurements of insulation resistance. polarization index, AC current. tan$\delta$, partial discharge. Destructive tests include measurements of AC hipot and DC hipot. This paper propose to establish the insulation diagnosis cycle for high voltage rotating machine.

  • PDF