• 제목/요약/키워드: Power limit

검색결과 1,458건 처리시간 0.042초

Fully Integrated HBT MMIC Series-Type Extended Doherty Amplifier for W-CDMA Handset Applications

  • Koo, Chan-Hoe;Kim, Jung-Hyun;Kwon, Young-Woo
    • ETRI Journal
    • /
    • 제32권1호
    • /
    • pp.151-153
    • /
    • 2010
  • A highly efficient linear and compactly integrated series-type Doherty power amplifier (PA) has been developed for wideband code-division multiple access handset applications. To overcome the size limit of a typical Doherty amplifier, all circuit elements, such as matching circuits and impedance transformers, are fully integrated into a single monolithic microwave integrated circuit (MMIC). The implemented PA shows a very low idle current of 25 mA and an excellent power-added efficiency of 25.1% at an output power of 19 dBm by using an extended Doherty concept. Accordingly, its average current consumption was reduced by 51% and 41% in urban and suburban environments, respectively, when compared with a class-AB PA. By adding a simple predistorter to the PA, the PA showed an adjacent channel leakage ratio better than -42 dBc over the whole output power range.

Analysis and Implementation of a DC-DC Converter with an Active Snubber

  • Lin, Bor-Ren;Lin, Li-An
    • Journal of Power Electronics
    • /
    • 제11권6호
    • /
    • pp.779-786
    • /
    • 2011
  • This paper presents a soft switching converter to achieve the functions of zero voltage switching (ZVS) turn-on for the power switches and dc voltage step-up. Two circuit modules are connected in parallel in order to achieve load current sharing and to reduce the size of the transformer core. An active snubber is connected between two transformers in order to absorb the energy stored in the leakage and magnetizing inductances and to limit the voltage stresses across the switches. During the commutation stage of the two complementary switches, the output capacitance of the two switches and the leakage inductance of the transformers are resonant. Thus, the power switches can be turned on under ZVS. No output filter inductor is used in the proposed converter and the voltage stresses of the output diodes is clamped to the output voltage. The circuit configuration, the operation principles and the design considerations are presented. Finally, laboratory experiments with a 340W prototype, verifying the effectiveness of the proposed converter, are described.

A Study on the Measurement of Whole-Body Vibration in Some Coal-fired Power Plant Workers

  • Heo, Seung-Moo;Lee, Yun Keun;Park, Hee Sok
    • 대한인간공학회지
    • /
    • 제32권4호
    • /
    • pp.341-344
    • /
    • 2013
  • Objective: This study measured and evaluated the characteristics of the whole body vibration experienced in some coal-fired power plant in Korea. Background: Few studies have been carried out in Korea about the effects of whole body vibration of power plants on humans. Method: The evaluation scheme suggested by the Law of Noise and Vibration Control was applied. Results: It was found that 28.9% of total measurement points were above the limit suggested by the law. Conclusion: Many workers are exposed to whole body vibration during their job completion, and more efforts should be applied to prevention and control of the plat vibration.

지역별 CO2 배출량규제를 고려한 발전소 최적운전 알고리즘의 개발 (Development of algorism to optimal operation of Power Generation considering Regional Regulation of CO2 Emission)

  • 김용하;김영길;이평호;조현미;우성민
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.1936-1941
    • /
    • 2010
  • This purpose of this paper is to propose a methodology for optimal generating operation in power system to minimize the cost of generation subject to not only system constraints but also regional $CO_2$ emission constraints. To solve this ELD problem calculated range limit on minimum and maximum power outputs by regional Equal Generator how each regional capacity is connected into one and expressed Equal Fuel Cost Function considering regional $CO_2$ emission constraints. Accordingly, being modified regional load, new power outputs considering regional $CO_2$ emission constraints were calculated by ELD. The proposed model for evaluating availability is tested on IEEE RTS(Reliability Test System)-24 in detail.

고정밀 자석전원을 위한 전류형 PWM 컨버터의 입출력 필터설계 (Input and output filter design of current source PWM converter for high-precision magnet power supply)

  • 김효성;최재호
    • 대한전기학회논문지
    • /
    • 제45권1호
    • /
    • pp.30-41
    • /
    • 1996
  • Current Source(CS) PWM converter is appropriate for the magnet power supply system which requests high power and high precision current control. Input and output filters should be installed to eliminate the current or voltage harmonics caused by the PWM switching for the CS PWM converter. But the input/output filters limit the output DC current range and may destroy the system with filter resonance, and make the system equation more complicated. In this paper, systematic and simple filter design method which considers not only the harmonic attenuation but also the total system good transfer function characteristics in the dc filter. The simulated and experimental results verify the proposed theory. (author). refs., figs., tabs.

  • PDF

Nd:YVO$_4$ 마이크로칩 레이저의 단일 종모드 동작 (Single Longitudinal Mode Operation in Nd:YVO$_4$ Microchip Laser)

  • 지명훈;김교준;이영우
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권6호
    • /
    • pp.260-264
    • /
    • 2002
  • We developed LD Pumped Nd:$VVO_4$ microchip laser with the cavity length of 1mm. The microchip laser output was 87.5㎽ at the wavelength of 1063.9nm with the input power of 241㎽ at the wavelength of 809nm. The slope efficiency was 40.7% and the threshold input power was 31.1㎽. We have also defined input power limit for the single longitudinal mode operation theoretically. It was 2.5 times larger than that of threshold input intensity. According to the results of simulation, the Nd:YVO$_4$ microchip laser can be operated with the maximum output of 15㎽ for the single longitudinal mode up to the input power of 77.75㎽.

New Fault Location Algorithms by Direct Analysis of Three-Phase Circuit Using Matrix Inverse Lemma for Unbalanced Distribution Power Systems

  • Park, Myeon-Song;Lee, Seung-Jae
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권2호
    • /
    • pp.79-84
    • /
    • 2003
  • Unbalanced systems, such as distribution systems, have difficulties in fault locations due to single-phase laterals and loads. This paper proposes new fault locations developed by the direct three-phase circuit analysis algorithms using matrix inverse lemma for the line-to-ground fault case and the line-to-line fault case in unbalanced systems. The fault location for balanced systems has been studied using the current distribution factor, by a conventional symmetrical transformation, but that for unbalanced systems has not been investigated due to their high complexity. The proposed algorithms overcome the limit of the conventional algorithm using the conventional symmetrical transformation, which requires the balanced system and are applicable to any power system but are particularly useful for unbalanced distribution systems. Their effectiveness has been proven through many EMTP simulations.

태양광 최대 전력 추종기를 위한 고효율 무손실 스너버 (High Efficiency Lossless Snubber for Photovoltaic Maximum Power Point Tracker)

  • 장두희;강정일;한상규
    • 전력전자학회논문지
    • /
    • 제18권5호
    • /
    • pp.485-491
    • /
    • 2013
  • A new passive lossless snubber for boost converter based on magnetic coupling is proposed. It is composed of a winding coupled with boost inductor, one snubber inductor, two snubber capacitor and three additional diodes. Especially, the snubber inductor can not only limit the reverse recovery current of output diode but also minimize switch turn-on losses greatly. Moreover, all of the energy stored in the snubber is transferred to the load in the manner of resonance. To confirm the validity of proposed system, theoretical analysis, design consideration, and verification of experimental results are presented.

전력계통의 중성선에 적용된 초전도한류기의 대칭고장전류 저감방안 분석 (Analysis on Reduction Method of Symmetrical Fault Current in a Power System with a SFCL applied into Neutral Line)

  • 임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제23권2호
    • /
    • pp.148-152
    • /
    • 2010
  • The superconducting fault current limiter (SFCL) applied into the neural line of a power system, which can limit the unsymmetrical fault current from the single-line ground fault or the double-line ground fault, was reported to be the effective application location of the SFCL in a power system. However, the limiting operation for the symmetrical fault current like the triple line-ground fault is not effective because of properties of the balanced three-phase system. In this paper, the limiting method of the symmetrical fault current in a power system with a SFCL applied into neutral line was suggested. Through the short-circuit experiments of the three-phase fault types for the suggested method, the fault current limiting and recovery characteristics of the SFCL in the neutral line were analyzed and the effectiveness of the suggested method was described.

발전소 운전 중 증기터빈 밸브 시험 방식 소개 (An Introduction to Test Methods about Steam Valves of Steam Turbines in Power Plants)

  • 최인규;우주희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1601-1602
    • /
    • 2007
  • Steam stop valves of steam turbine in the power plant are at their 100% position and have no movements. Steam control valves, ie governor valves have no movements either at their controlling position on load limit operation. By the way, if there were no change of operation state, steam valves could be sticked mechanically. Because the governor could fail in protecting and controlling steam turbine in case of emergency conditions, the closing test of 100% valve travel must be accomplished periodically for the purpose of testimony of their good conditions. And, As the difference between steam turbine structures exists according to the manufacturer or generation capacity, both steam stop valves and steam control valves differes in structure and operation method. Therefore, it is essential for not only turbine protection but also control for the control engineers to find out composition of steam valves and method of closing test.

  • PDF