• 제목/요약/키워드: Power intensity

검색결과 1,347건 처리시간 0.03초

A Study on High Speed Laser Welding by using Scanner and Industrial Robot (스캐너와 산업용 로봇을 이용한 고속 레이저 용접에 관한 연구)

  • Kang, Hee-Shin;Suh, Jeong;Kim, Jong-Su;Kim, Jeng-O;Cho, Taik-Dong
    • Proceedings of the KWS Conference
    • /
    • 대한용접접합학회 2009년 추계학술발표대회
    • /
    • pp.29-29
    • /
    • 2009
  • On this research, laser welding technology for manufacturing automobile body is studied. Laser welding technology is one of the important technologies used in the manufacturing of lighter, safer automotive bodies at a high level of productivity; the leading automotive manufacturers have replaced spot welding with laser welding in the process of car body assembly. Korean auto manufacturers are developing and applying the laser welding technology using a high output power Nd:YAG laser and a 6-axes industrial robot. On the other hand, the robot-based remote laser welding system was equipped with a long focal laser scanner system in robotic end effect. Laser system, robot system, and scanner system are used for realizing the high speed laser welding system. The remote laser welding system and industrial robotic system are used to consist of robot-based remote laser welding system. The robot-based remote laser welding system is flexible and able to improve laser welding speed compared with traditional welding as spot welding and laser welding. The robot-based remote laser systems used in this study were Trumpf's 4kW Nd:YAG laser (HL4006D) and IPG's 1.6kW Fiber laser (YLR-1600), while the robot systems were of ABB's IRB6400R (payload:120kg) and Hyundai Heavy Industry's HX130-02 (payload:130kg). In addition, a study of quality evaluation and monitoring technology for the remote laser welding was conducted. The welding joints of steel plate and steel plate coated with zinc were butt and lapped joints. The quality testing of the laser welding was conducted by observing the shape of the beads on the plate and the cross-section of the welded parts, analyzing the results of mechanical tension test, and monitoring the plasma intensity and temperature by using UV and IR detectors. Over the past years, Trumf's 4kW Nd:YAG laser and ABB's IRB6400R robot system was used. Nowadays, the new laser source, robot and laser scanner system are used to increase the processing speed and to improve the efficiency of processes. This paper proposes the robot-based remote laser welding system as a means of resolving the limited welding speed and accuracy of conventional laser welding systems.

  • PDF

Quality and physicochemical characteristics of soybean flours after germination and roasting (발아와 볶음처리에 따른 콩가루 품질 및 이화학 특성)

  • Woo, Koan Sik;Kim, Hyun-Joo;Lee, Ji Hae;Lee, Byong Won;Lee, Yu Young;Lee, Byoung Kyu
    • Korean Journal of Food Science and Technology
    • /
    • 제50권2호
    • /
    • pp.143-151
    • /
    • 2018
  • The quality and physicochemical characteristics of the soybean flours after germination and roasting were evaluated to partly fulfill the purpose of establishing quality standards of soybean flours for each of their applications. Moisture content of roasted soybean flours decreased significantly based on the roasting conditions, and crude ash, protein, and fat content increased. Water binding capacity increases with an increase in roasting temperature and time; however, water solubility index and swelling power decreased. The lightness of roasted soybean flour decreased significantly, and its redness and yellowness increased in intensity. Phenolic compounds and radical scavenging activity of roasted soybean flour increased with an increase in roasting temperature and time. 2,2'-Azino-bis(3-ethylbenzothiazoline-6-sulphonic acid) radical scavenging activity of roasted soybean flour without and with germination was 380.88-537.32 and 419.34-587.99 mg TE/100 g, respectively. Consequently, it is necessary to set quality standards for each application, considering the quality and antioxidant properties of roasted soybean flours.

InAs/GaAs 양자점 태양전지의 Photoreflectance Spectra에서 AlGaAs Potential Barrier 두께에 따른 Franz Keldysh Oscillation 주파수 특성

  • Son, Chang-Won;Lee, Seung-Hyeon;Han, Im-Sik;Min, Seong-Sik;Ha, Jae-Du;Lee, Sang-Jo;Smith, Ryan P.;Kim, Jong-Su;Lee, Sang-Jun;No, Sam-Gyu;Kim, Jin-Su;Choe, Hyeon-Gwang;Im, Jae-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.441-441
    • /
    • 2012
  • Franz Keldysh Oscillation (FKO)은 p-n 접합 구조의 Photoreflectance (PR) spectra에서 표면 및 계면의 전기장(electric field) 특성을 반영한다. InAs/GaAs 양자점 태양전지(Quantum Dot Solar Cell, QDSC) 구조에서 InAs 양자점 층 전후에 AlGaAs 층을 삽입하여 퍼텐셜 장벽(potential barrier) 두께에 따른 PR spectra 및 GaAs-matrix에서 FKO 주파수 특성을 비교 분석하였다. InAs/GaAs 양자점 태양전지는 p-i-n 구조의 i-GaAs에 2.0 monolayer (ML), 8주기의 InAs 양자점 층을 삽입하여 Molecular Beam Epitaxy (MBE) 방법으로 성장하였다. 각 양자점 층 전후에 두께가 각각 0.0, 1.6, 2.8, 6.0 nm인 AlGaAs 층을 삽입하여 퍼텐셜 장벽 두께에 따른 FKO 주파수 변화를 관측하였다. 또한 태양전지 구조의 전기장 분포를 좀 더 용이하게 관측하기 위해 여기 광의 세기(power intensity)를 충분히 낮추어 Photovoltaic effect에 의한 내부 전기장의 변화를 최소화하여 비교 분석하였다. InAs/GaAs 양자점 태양전지 구조에서 AlGaAs 장벽층이 없는 경우, PR spectra의 Fast Fourier Transform 결과에 반영되는 FKO 주파수 특성은 p-i-n 구조 계면에서 공핍층(depletion region)의 space charge field보다 양자점 층의 내부 전기장에 의한 FKO 주파수가 더 큰 진폭(amplitude)을 보였다. 반면에, AlGaAs 장벽층이 삽입되면 두께가 커짐에 따라 p-i-n 구조 계면의 space charge field에 의해 더 큰 진폭의 FKO 주파수가 관측되었다. 이는 AlGaAs 장벽층이 삽입됨으로써 양자점 층 내 양자 상태 수 및 여기광에 의한 캐리어의 수와 관련이 있음을 확인하였으며, 결과적으로 GaAs-matrix에서 p-i-n 구조 계면의 space charge field에 영향을 미치게 됨을 알 수 있다. 이러한 PR 특성 결과들을 InAs/GaAs 양자점 태양전지의 설계 및 제조에 반영함으로써 양자효율 증대에 기여할 것으로 기대된다.

  • PDF

The Conflict over the Separation of Prescribing and Dispensing Practice (SPDP) in Korea: A Bargaining Perspective (의약분업을 둘러싼 갈등 : 협상론의 관점에서)

  • Lee, Kyung-Won;Kim, Joung-Hwa;T. K. Ahn
    • Health Policy and Management
    • /
    • 제12권4호
    • /
    • pp.91-113
    • /
    • 2002
  • We report and analyze the Korean physicians' recent general strike over the implementation of the Separation of Prescribing and Dispensing Practice (SPDP) in which more than 18,000 private clinics and 280 hospitals participated. Utilizing game-theoretic models of bargaining we explain why the Korean physicians were so successful in organizing intense collective action against the government and securing very favorable policy outcomes. In particular, we highlight the role of distributional conflict among social actors in shaping the details of institutional reform. The introduction of the SPDP was a necessary first step in the overall reform of health care system in Korea. However, the SPDP was perceived to be a serious threat to the economic viability of their profession by the vast majority of Korean physicians who had long been relied on the profits from selling medicines to compensate for the loss of income due to the low service fee under the previous health care system. The strong political coalition among heterogeneous physicians enabled them to organize an intense form of collective action, the general strike. Thus, physicians were successful not only in dragging the government to a bargaining table, but also winning in the bargaining and securing an outcome vastly favorable to them. On the other hand, the lack of an overall reform plan in the health care policy area, especially the finance of the National Health Insurance and the need for maintaining an image as a successful reform initiator, motivated the government to reach a quick resolution with the striking physicians.

LED Source Optimization for the LED Chip Array of the LED Luminaires (LED 조명기구에서 LED 칩 배치에 따른 광원 최적화)

  • Yoon, Seok-Beom;Chang, Eun-Young
    • Journal of Digital Convergence
    • /
    • 제14권4호
    • /
    • pp.419-424
    • /
    • 2016
  • In this paper, we studied a light distribution for the LED chips arrangement using an optical design software. The structures of the edge type LED luminaires are reflector plane, LGP(lighting guide plane) and diffuse plane. The reflector plane is on the middle of the overall structure. We had simulation that placing LED chips on the reflector center of the reflector edge by changing the position of LED chips above the reflector center at 1mm, 2mm, and 3mm respectively. In the case, when LED chips are on the center of the reflector, it shows the light distribution of the general diffuse illumination, the semi-direct distribution with 0.56 efficiency and the direct distribution with 0.31 efficiency. And the wedge type LGP shows more efficiency than the flat type. Gradually increasing shape of semi-spherical type by 0.015mm has power of 1.02W, efficiency of 0.25, and maximum luminous intensity of 0.104W/sr, it also and shows the better optical characteristics than the reflector plane that have no patterns. This semi-spherical type shows the better optical characteristics than the reflector plane that have no patterns.

An Experimental Study on the Application of LIBS for the Diagnosis of Concrete Deterioration (콘크리트 열화 진단의 LIBS 적용을 위한 실험적 연구)

  • Woo, Sang-Kyun;Chu, In-Yeop;Youn, Byong-Don
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제21권6호
    • /
    • pp.140-146
    • /
    • 2017
  • It is laser induced breakdown spectroscopy(LIBS) that enables qualitative and quantitative analysis of the elements contained in unknown specimen by comparing the wavelength characteristics of each element obtained from the spectral analysis of the standard specimen with the wavelength analysis results from unknown specimens. In this study, the applicability of LIBS to the analysis of major deterioration factors affecting concrete durability was experimentally analyzed. That is, the possibility of applying LIBS to the diagnosis of concrete deterioration by studying the quantitative detection of harmful deteriorating factors on chloride, sulfate and carbonated mortar specimens using LIBS was studied. As a result of LIBS test for each chloride and sulfate specimen, the LIBS spectral wavelength intensity of chlorine and sulfur ions increased linearly with increasing concentration. Carbon ion LIBS spectral wave intensities of carbonated specimens increased nonlinearly over the duration of carbonation exposure. From the above results, it can be partially confirmed that LIBS can be applied to the diagnosis of concrete deterioration. In case of concrete carbonation, it is presumed that carbon content is contained in the cement itself and is different from the detection of chloride and sulfate specimen. Therefore, it is considered that more various parameter studies should be performed to apply LIBS to concrete carbonation.

Quantitative Analysis of Voice Quality after Radiation Therapy for Stage T1a Glottic Carcinoma (T1a 병기 성문암의 방사선 치료 후 음성에 관한 연구)

  • Lee Joon-Kyoo;Chung Woong-Gi
    • Radiation Oncology Journal
    • /
    • 제23권1호
    • /
    • pp.17-21
    • /
    • 2005
  • Purpose : To evaluate the voices of irradiated patients with early glottic carcinoma and to compare these with the voices of healthy volunteers. Materials and Methods : The voice samples (sustained vowel) of seventeen male patients who had been irradiated for T1a glottic squamous carcinoma at least 1 year prior to the study were analyzed with objective voice analyzer (acoustic voice analysis, aerodynamic test, and videostroboscopic analysis) and compared with those of a normal group of twenty age- and sex-matched volunteers. Average fundamental frequency, jitter, shimmer, and noise-to-harmonic ratio were obtained for acoustic voice analysis. Maximal phonation time, mean flow rate, intensity, subglottic pressure, glottal resistance, glottal efficiency, and glottal power were obtained for aerodynamic test. Results : The irradiated group presented higher values of shimmer in acoustic voice analysis. There was no significant difference between two groups in other parameters. Conclusion : In this study all the objective voice parameters except shimmer were no4 significantly different between the irradiated group and the control group. These results suggest that the voice quality is minimally affected by radiation therapy for 71 a glottic carcinoma.

High-Order Surface Gradient Coil Design Using Target Field Approach

  • Lee, J.K.;Yang, Y.J.;Jeong, S.T.;Choi, H.J.;Cho, Z.H.;Oh, C.H.
    • Journal of Biomedical Engineering Research
    • /
    • 제17권1호
    • /
    • pp.19-24
    • /
    • 1996
  • The purpose of this paper is to design high-order (or radial) surface gradient coil (SGC), which can provide multi-dimensional spatial selection. Although the spatial Selection with High-Order gradienT (SHOT) can provide a 2-D selection with only one selective RF pulse, the high-order gradient pro- duced by conventional cylindrical-shape coils has not been clinically useful due to the large selection size caused by the limited radial gradient intensity. However, by using the proposed high-order SGCs located near the imaging region, the size of volume selection can be reduced to a clinically useflll size of 1-2 cm in diameter by applying stronger radial gradient field with much less gradient driving power. So far radial SGCs have been designed by using the field component method and may cause distortion in the selection shapes. In this paper, by using the target field approach for the coil design, selected volumes became almost circular. A 40 cm-by-40 cm $z^2$_surface gradient coil has been designed and implemented by using the target field approach. Phantom and volunteer studies have been performed Experimental results using spatially localized MRI show good agreement to the theoretically predicted behavior.

  • PDF

Color Image Rendering using A Modified Image Formation Model (변형된 영상 생성 모델을 이용한 칼라 영상 보정)

  • Choi, Ho-Hyoung;Yun, Byoung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • 제48권1호
    • /
    • pp.71-79
    • /
    • 2011
  • The objective of the imaging pipeline is to transform the original scene into a display image that appear similar, Generally, gamma adjustment or histogram-based method is modified to improve the contrast and detail. However, this is insufficient as the intensity and the chromaticity of illumination vary with geometric position. Thus, MSR (Multi-Scale Retinex) has been proposed. the MSR is based on a channel-independent logarithm, and it is dependent on the scale of the Gaussian filter, which varies according to input image. Therefore, after correcting the color, image quality degradations, such as halo, graying-out, and dominated color, may occur. Accordingly, this paper presents a novel color correction method using a modified image formation model in which the image is divided into three components such as global illumination, local illumination, and reflectance. The global illumination is obtained through Gaussian filtering of the original image, and the local illumination is estimated by using JND-based adaptive filter. Thereafter, the reflectance is estimated by dividing the original image by the estimated global and the local illumination to remove the influence of the illumination effects. The output image is obtained based on sRGB color representation. The experiment results show that the proposed method yields better performance of color correction over the conventional methods.

Development of Thermoluminescence and Optical Stimulated Luminescence Measurements System (열자극발광 및 광자극발광 측정장치의 개발)

  • Park, Chang-Young;Chung, Ki-Soo;Lee, Jong-Duk;Chang, In-Su;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • 제40권1호
    • /
    • pp.46-54
    • /
    • 2015
  • The thermoluminescence (TL) and optically stimulated luminescence (OSL) are commonly used to measure and record the expose of individuals to ionization radiation. Design and performance test results of a newly developed TL and OSL measurement system are presented in this paper. For this purpose, the temperature of the TL material can be controlled precisely in the range of $1{\sim}1.5^{\circ}C$ by using high-frequency (35 kHz) heating system. This high-frequency power supply was made of transformer with ferrite core. For optical stimulation, we have completed an optimal combination of the filters with the arrangement of GG420 filter for filtering the stimulating light source and a UG11 filter at the detecting window (PMT). By using a high luminance blue LED (Luxeon V), sufficient luminous intensity could be obtained for optical stimulation. By using various control boards, the TL/OSL reader device was successfully interfaced with a personal computer. A software based on LabView program (National Instruments, Inc.) was also developed to control the TL/OSL reader system. In this study, a multi-functional TL/OSL dosimeter was developed and the performance testing of the system was carried out to confirm its reliability and reproducibility.