• Title/Summary/Keyword: Power generation project

Search Result 175, Processing Time 0.028 seconds

Analysis for the Economic efficiency of District Heating and Gas Engine Co-generation System comparing with Central Heating System (중앙난방방식을 지역난방.소형열병합난방방식으로 전환시의 경제성 비교 분석)

  • Kim, Kyu-Saeng;Lee, Sang-Hyeok;Hong, Kyung-Pyo;Won, Young-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.459-465
    • /
    • 2007
  • This study was conducted to calculate the LCC of a apartment complex with a type of heating system, district heating and cogeneration system. For the purpose of analyzing LCC according to size of apartment complex, 500, 1,500 and 4,000 houses of model apartment selected. This research performs design of heating system and the life cycle cost analysis including an initial cost, energy cost, maintenance and operation cost, replacement cost and renovation cost during the project period(15years). According to the calculated results, 1) Initial cost of cogeneration system with 500, 1500 and 4000 houses is higher than district heating system each of 20%, 13%, 12%. 2) In case of cogeneration system, the payback period by electric generation is 5.21, 4.92 and 4.47 years and saving cost was calculated 29 billion won, 94 billion won and 262 billion won after payback period. 3) Cogeneration system LCC was 1.12, 1.07 and 1.06 times larger than district system with the size of apartment complex. According to the case of this study district heating system is more efficient than cogeneration system in terms of the reduction of LCC. 4) Gas Engine Co-generation System is more efficient than other systems because it can collect progressive part from electric charge progressive stage system. However, the efficiency is decreasing because of raising of fuel bills(LNG) and lowering of power rate for house use. Especially the engine is foreign-made so the cost of maintenance and repair is high and the technical expert is short. 5) District heating is also affected by fuel bills so we should improve energy efficiency through recovering of waste heat(incineration heat, etc.). Also, we should supply district cooling on the pattern of heat using of let the temperature high in winter and low in summer.

  • PDF

An External Costs Assessment of the Impacts on Human Health from Nuclear Power Plants in Korea (국내원전운전(國內原電運轉)에 따른 보건영향(保健影響)의 외부비용평가(外部費用評價))

  • Kim, Kyoung-Pyo;Kang, Hee-Jung
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.67-76
    • /
    • 2008
  • As the first comprehensive attempt at a national implementation, this study aims at assessing the external costs of major electricity generation technologies in Korea, particularly an evaluation of the impacts on human health resulting from exposures to atmospheric radiological emissions from nuclear power plants, and a monetary quantification of their damages. The methodology used for the assessment of the externalities of the selected fuel cycles has been developed by the International Atomic Energy Agency (IAEA), namely the SimPacts Model Package. The model is internationally recognized as a tool which can be applied to a wide range of fuels, different technologies and locations, for an externalities study. In this study, the relevant emissions are quantified first and then their impacts on human health are evaluated and compared. The study focused on all the nuclear power plants for the last 6 years ($2001{\sim}2006$) in Korea. With respect to nuclear power, the impact analysis only focuses on a power generation, however the front- and back-end nuclear fuel cycles are not included, namely uranium mining, conversion, enrichment, reprocessing, conditioning, etc., because these facilities are not present in Korea. The analysis results show that nuclear power in general, generates low external costs. The highest damage costs from the nuclear power plants among the 4 sites in Korea were estimated to be 3.9 mills/MWh, which is about 1/20th of the result for a similar case study conducted in the U.K., implemented through the ExternE project. This difference is largely due to the number of radionuclides included in the study and the amount of released radioactive emissions based on up-to-date information in Korea. In this study, the sensitivities of the major factors for nuclear power plants were also calculated. The analysis indicates that there was around a ${\pm}3%$ damage costs variation to a ${\pm}15%$ change of the reference population density and a ${\pm}1%$ damage cost variation to a $1{\sim}30$ meters change of the effective release height, respectively. These sensitive calculations show that there is only a minor difference when the reference costs are compared.

Review of Real Options Analysis for Renewable Energy Projects (실물옵션 기법을 활용한 신재생에너지사업 경제성분석에 관한 연구)

  • Kim, Kyeongseok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.2
    • /
    • pp.91-98
    • /
    • 2017
  • Due to climate change, countries around the world are actively investing in renewable energy, reducing fossil fuel use. 23.7% of world electricity is supplied by renewable energy. As the technology continues to develop, it is in a level to compete in terms of power generation cost, and investment conditions are improving. However, investment in renewable energy projects is not easy. This study analyzed trends of domestic and international researches on economics assessment applying real options analysis to investment decisions of hydro, solar, and wind power projects, which account for a large portion of renewable energy. This study provides (1) the difference between the traditional economic method and the real options analysis, (2) the application process, and (3) the uncertainty elements and option type of the renewable energy project presented by many studies. The real options analysis is suitable for the detailed investment strategy by considering the uncertainties of the renewable energy project and applying the option to improve the profit or to avoid the risk.

The State of the Art of the Fuel Cells (연료전지 기술현황)

  • Lee, Jin-Hong;ShunWoo, Hyun-Bum
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.3-12
    • /
    • 1991
  • Fuel cells are electrochemical devices that convert the chemical reaction energy directly into the electrical energy. In a typical fuel cell, gaseous fuel is fed continuously to the anode(negative electrode) compartment and the oxidant(i.e, oxygen from air) is fed continuously to the cathode(positive electrode) compartment; the electrochemical reactions take place at the electrodes to produce an electric current. Many of the operational characteristics of fuel cell systems are superior to those of conventional power generation system because of good efficiency, environmental protection, safty, modularity etc. From those reasons, the fuel cells are considered to be the solution to the future problem of energy conversion. The objective of this paper is to introduce the technical status of fuel cell technologies and our national project for the development of the phosporic acid fuel cell.

  • PDF

Simulation of DC Microgrid with PV Generation (태양광 발전이 연계된 DC 마이크로 그리드의 시뮬레이션)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.267-273
    • /
    • 2017
  • In recent years, there is an increasing demand for DC microgrid because the digital load due to DC increases and the efficiency of the distribution system increases due to loss of conversion losses and conversion stages due to reactive power compared to AC distribution. Currently, with the support of the KEPRI, the development of an electronic large-capacity circuit breaker for DC distribution protection, which has been underway since 2016, is proceeding. In this paper, as a part of this project, we modeled the DC microgrid connected with PV using PSCAD. The converter station, AC/DC converter control, PV and MPPT controller are designed. In order to evaluate the performance of the modeled DC microgrid, it is examined whether the voltage is adjusted according to the load variation.

An Optimum Decision Feedback Equalizer for SC-FDMA Systems (SC-FDMA 시스템을 위한 최적 판정궤환 등화기)

  • Lee, Su-Kyoung;Park, Yong-Hyun;Seo, Bo-Seok
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2010.07a
    • /
    • pp.417-419
    • /
    • 2010
  • SC-FDMA(Single Carrier Frequency Division Multiple Access) 방식은 다중경로의 영향을 제거할 수 있는 OFDM(Orthogonal Frequency Division Multiplexing) 방식의 장점을 유지하면서 OFDM의 단점인 높은 PAPR(Peak to Average Power Ratio) 문제를 해결할 수 있어 차세대 멀티미디어용 이동통신 시스템인 3GPP LTE(3rd Generation Partnership Project Long Term Evolution)의 상향링크 전송방식으로 채택되었다. 또한 SC-FDMA 수신기는 주파수 영역에서 채널등화기를 구현함으로써 OFDM 수신기와 마찬가지로 기존의 단일반송파 방식에 비해 등화기의 복잡도를 크게 감소시킬 수 있다. 한편 주파수 영역 채널등화기와 더불어 시간영역의 판정궤환 등화기를 같이 사용하여 수신기의 성능을 향상 시킬수 있다. 이 논문에서는 예측형 판정궤환 등화기 구조를 적용하여 채널등화기의 성능을 더 향상시킬 수 있는 방법을 제안하고자 한다. 또 모의실험을 통해 제안된 방법의 성능을 확인한다.

  • PDF

performance Analysis or the IMT-2000 system receiver with Array Antenna and MRC-Diversity (Array 안테나와 MRC-Diversity를 채용한 IMT-2000 시스템의 수신성능 분석)

  • 왕용철;강희조;우병훈
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2001.06a
    • /
    • pp.256-260
    • /
    • 2001
  • 본 논문은 광대역 무선통신환경에서 3GPP(3rd Generation Partnership Project)에 기반한 비동기 IMT-2000 시스템의 송수신 시스템을 구성하여 기지국의 수신성능을 분석하였다. 이동국과 기지국간의 Uplink 채널 환경을 고려하였으며, 기지국의 수신신호는 다중경로 페이딩(Multi-path Fading)과 다중접속간섭(Mult Access Interference : MAI)의 영향으로 성능일 열화된다. 이에 대한 대책으로 Array 안테나를 채용하였을 경우와 MRC-Diversity(Maximal Combining Diversity)를 채용하였을 경우의 수신성능을 동일한 환경에서 비교 분석하였으며, 각각의 시스템에 간섭제거기를 직렬로 비교분석하였다. 본 논문에서 적용한 Array 안테나는 수신 신호의 방향에 따라 적응적으로 추적하여 수신 SNR(Singnal-to-Noise power Ratio)을 최대로 형성하여 시스템의 성능을 개선하는 기법이며, 안테나의 방향성(Directivity :D=2.67)을 이용하는 3-element Array 안테나를 채용하였다. 최대비 합성 다이버시티 기법은 다이버시티 기법 중 수신효율이 가장 좋으며 가지수(L=2)를 함수를 사용하였다. 성능분석 결과 다중경로 페이딩과 다중접속간섭 환경에서 최대비 합성 다이버시티 기법이 Array 안테나보다 수신효율이 우수하였다.

  • PDF

A process of developing experimental Korean image fashion items focused on jeans and T-shirts (한국의 이미지를 이용한 의류상품개발 모델의 연구 -청바지와 티셔츠를 중심으로-)

  • 이영미;이상은
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.5 no.3
    • /
    • pp.49-61
    • /
    • 2003
  • This study is a process of developing experimental Korean image fashion items that can appeal to the younger generation. The sample models are focused on jeans and T-shirts. This project had two goals. First, giving chance to the students of Konkuk-University of producing fashion items adopting Korean image in university venture company. Second, contributing to Korean image fashion market if the items have been proved to have competitive power through the market of Konkuk-University and it's cooperated company. The research is restricted within ornament techniques of Korean traditional dress and its ornament's element, they are patchwork wrapping-cloth(Chokakbo), embroidery, gold and silver foil on cloths, and transcription. Such Korean image elements are graphic patterned as 30 jeans and 50 T-shirts and eventually evaluated by 100 university students majoring in garments. The evaluation scale contains repletion of Korean image, possibility of market, and preference. Through this process, 6 jeans and 7 T-shirts were produced.

  • PDF

Analysis of Sediment Flushing Effect for Reservoir Sedimentation Management of the Patrind Dam in Pakistan (파키스탄 파트린드댐의 저수지 퇴사관리를 위한 배사효과 분석)

  • Noh, Joonwoo;Park, Jinhyeog;Hur, Youngteck;Kim, Sangho
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.6
    • /
    • pp.799-807
    • /
    • 2013
  • Reservoir sedimentation is one of the major concerns for sustainable reservoir operation. Since sediment concentration of the rivers in the Himalayan Mountain is very high, a proper sediment management scheme is necessary. This paper presents long-term reservoir sedimentation and sediment flushing based on the gate operation. Focused on the reservoir to be constructed for the Patrind hydropower project in Pakistan, 4 different flushing scenarios were proposed in this study to prevent successive sedimentation. By extending flushing period and by increasing the flushing discharge for 2 times, the flushing rate increases up to 53.2% and 43.6% in proportion to flushing period and discharge, respectively. Based on the simulation presented in this paper, it is expected to establish efficient sediment management plan to increase hydro power generation and sediment flushing simultaneously.

Analysis of Macro-Diversity in LTE-Advanced

  • Kim, Gun-Yeob Peter;Lee, Jung-Ah C.;Hong, Sang-Jin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.9
    • /
    • pp.1596-1612
    • /
    • 2011
  • Coordinated Multi-Point (CoMP) transmission / reception is being studied in Long Term Evolution-Advanced (LTE-A) for future evolution of the $3^{rd}$ Generation Partnership Project (3GPP) LTE. Support of soft handover is essential for improving the performance of cell edge users. CoMP provides a natural framework for enabling soft handover in the LTE system. This paper evaluates the soft handover gain in LTE-A downlink. Mathematical analysis of signal to interference plus noise ratio (SINR) gain and the handover margins for soft handover and hard handover are derived. CoMP system model is developed and an inter-cell and intra-cell interference model is derived, taking into account the pathloss, shadowing, cell loading, and traffic activity. Reference signal received power (RSRP) is used to define the triggers and the measurements for soft handover. Our results indicate that parameter choices such as handover margin and the CoMP set size impact CoMP performance gain.