• Title/Summary/Keyword: Power feedback

Search Result 1,260, Processing Time 0.026 seconds

A Feedforward Linear Power Amplifier using Error Feedback Technique (에러 피드백 기술을 이용한 피드 포워드 선형 전력 증폭기)

  • 김완종;조경준;김종헌;김남영;이종철;이병제
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.8
    • /
    • pp.1407-1413
    • /
    • 2000
  • This paper presents a feedforward linear power amplifier (LPA) using error feedback technique to achieve low intermodulation distortions(IMD) of power amplifiers for base stations. Especially, the proposed linear power amplifier is applied to feedforward technique combined with error feedback technique, which has no loss of amplifier gain unlike typical feedback technique. The proposed LPA is designed by using HP ADS ver. 1.3, fabricated. When two-tone signals at 1850 MHz and 1851.25 MHz with -7 dBm/tone from synthesizers are injected into the main power amplifier with gain of 28 dB and P1dB of 1W, the proposed LPA could reduce more than 35 dB.

  • PDF

A Study on 800 MHz 1W Cartesian Feedback Linearized Power Amplifier for TETRA Signals (TETRA 신호를 위한 800 MHz 대역 1W 급 Cartesian feedback 선형 전력 증폭기에 관한 연구)

  • Oh, Duk-Soo;Kim, Ji-Yeon;Chun, Sang-Hyun;Kim, Jong-Heon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.4
    • /
    • pp.76-85
    • /
    • 2008
  • In this paper, a 800 MHz 1 W cartesian feedback linearized power amplifier is designed and fabricated for TETRA handset application. For amplification of TETRA signal with 200 kHz narrow bandwidth, amplifier linearization performance of more than 30 dBc is improved through the cartesian feedback linearizer at the offset Sequency of ${\pm}25$ kHz. It is clear that the linearization performance is affected by imbalance of gain and phase between I/Q signals and also DC offset. The linearization performance can be maximized by the compensation of those influences. Cartesian feedback is suitable for a liearization technique of narrow band signal with QAM and another modulation signals, as well.

  • PDF

Interference Cancellation System to Prevent the Oscillation of the Wireless Communication System using the Same Frequency (동일 주파수 무선통신 시스템의 발진방지를 위한 간섭잡음제거기)

  • 김선진;김남영
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.3
    • /
    • pp.253-262
    • /
    • 2003
  • In this paper, the interference cancellation system, which is used to cancel the feedback signal in the wireless communication system with the same frequency, is studied. The time varying feedback signal generated from transmitter antenna to receiver antenna reduces the performance of the receiver system. the interference cancellation system using adaptive feedback method(AF-ICS) is suggested to prevent the oscillation of the receiver system and maintain the maximum output power of the power amplifier by the reduction of time-varying feedback signal and also this paper conforms that the oscillation disappears from the output signal by cancellation of the feedback signal and the total output power is satisfied the system specification.

The Design of Ultra-broadband Power Amplifier using a Negative Feedback (부궤환을 이용한 광대역 전력증폭기 설계)

  • Lee, Han-Young;Kim, Dae-Jung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1572-1579
    • /
    • 2009
  • In this dissertation ultra-broadband power amplifier(UPA) was designed and fabricated using negative feedback technique. UPA was made of pre-amplifier, drive amplifier and power amplifier. Negative feedback technique was used to achieve ultra-broadband performance. Designed power amplifier has 30dB gain and 2W output power. The load-pull data of power amplifier for optimal power matching was extracted from the measured S-parameter. Fabricated PCB material, permittivity is 4.6 and thickness is 0.8mm, is FR4 and UPA was fabricated 3 modules for comparison of the simulated and measured results. Size of the fabricated pre-amplifier and drive amplifier module is 40mm'50mm'16mm. And from the experimental results, gain of the pre-amplifier module is 9.87dB at 2GHz and flatness is 0.63dB. Experimental result of the drive amplifier module is 10.97dB at 2GHz and flatness of that is 0.26dB. Test result of the power amplifier module is 10.71dB at 2GHz and flatness is 0.72dB. Total size of the power amplifier is 45mm'134mm'16mm. According to the test results, gain of the UPA is 28.98dB at 2GHz and flatness is 1.68dB. Output power was 32.098dBm at 2GHz, 32.154dBm at 1GHz and 31.273dBm at 100MHz.

Reactive Power P&O Islanding Detection Method using Positive Feedback (Positive Feedback을 이용한 무효전력 P&O 단독운전 검출기법)

  • Lee, Jong-Won;Park, Sung-Youl;Lee, Jae-Yeon;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.410-416
    • /
    • 2022
  • A grid-connected inverter with critical loads uses mode transfer control to supply stable voltage to the load. An islanding detection method should also be used to quickly detect the grid fault and disconnect the inverter from the grid. However using the existing islanding detection method to detect islanding is difficult due to the small fluctuation of the voltage and frequency of the point of common coupling. This study proposes a reactive power P&O islanding detection method by using the positive feedback technique. The proposed method always injects a small variation of reactive power. When a grid fault occurs, the injected reactive power accelerates the reactive power injection reference. As a result, the reactive power reference value and the sensed reactive power become mismatched, and islanding is detected. Reducing the amount of real-time injected reactive power results in high efficiency and power factor. The simulation and experimental results of a 3 kW single-phase inverter are provided to verify the proposed islanding detection method.

Power system stabilization via adaptive feedback linearization (비선형 적응제어를 이용한 전력계통 안정화)

  • 윤태웅;이도관
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1221-1224
    • /
    • 1996
  • As in most industrial processes, the dynamic characteristics of an electric power system are subject to changes. Amongst those effects which cause the system to be uncertain, faults on transmission lines are considered. For the stabilization of the power system, we present an indirect adaptive control method, which is capable of tracking a sudden change in the effective reactance of a transmission line. As the plant dynamics are nonlinear, an input-output feedback linearization method is combined with an identification algorithm which estimates the effect of a fault.

  • PDF

Input Impedance and Current Feedforward Control of Single-Phase Boost PFC Converters

  • Park, Sungmin;Park, Sung-Yeul;Bazzi, Ali M.
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.577-586
    • /
    • 2015
  • The combination of voltage feedforward and feedback control is a conventional approach for correcting the power factor in single-phase ac-dc boost converters. The feedback duty ratio increases significantly with an increase of the line frequency and input inductance. Therefore, the performance of the conventional approach is highly dependent on the bandwidth of the feedback controller. As a result, the input power quality can be significantly exacerbated due to uncompensated duty ratios if the feedback controller is limited. This paper proposes an input impedance and current feedforward control method to reduce the control portion of the feedback controller. The findings in this paper are 1) the theoretical derivation and analysis of variations of line frequency and input inductance on a power factor correction approach, 2) guaranteed consistent performance in a wide range of conditions, and 3) that a low switching frequency can be utilized by the proposed method. A MATLAB/Simulink model and a 1.2kW dual boost converter are built to demonstrate the effectiveness of the proposed method.

Reduction of Sound Radiated Power of Clamped Beams using Filtered Velocity Feedback Controllers (Filtered Velocity Feedback 제어기를 이용한 양단지지보의 음향파워 저감)

  • Shin, Chang-Joo;Hong, Chin-Suk;Jeong, Weui-Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.12
    • /
    • pp.1104-1111
    • /
    • 2011
  • This paper investigates the filtered velocity feedback(FVF) controller for the reduction of the acoustic power radiated from a clamped beam. The instability problem due to the non-collocated sensor/actuator configuration when using PZT actuator should be sorted out. The roll-off property of the FVF controller at high frequency helps to alleviate the instability. The dynamics of clamped beams under forces and moments pair and the FVF controller are first formulated. The formulation of the sound radiated power is followed. The open loop transfer function(OLTF) synthesized with 100 modes is used to determine the stability of the control system. The control performance is finally estimated. The levels of the vibration and the sound radiated power are reduced in the wide bandbelow the tuning mode of the FVF controller.

Design and Fabrication of 10W Feedforward Linear Power Amplifier adding Feedback Loop for IMT-2000 (궤한루프를 첨가한 IMT-2000용 10W급 Feedforward 선형 전력 증폭기의 설계 및 제작)

  • 류병하;장중호;김성민;최현철
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2000.11a
    • /
    • pp.187-190
    • /
    • 2000
  • In this paper, A Feedforward Linear Power Amplifier which is appended a feedback loop for IMT-2000 was designed and fabricated. Feedback loop was used to improve the IMD(Inter-Modulation Distortion) characteristics of the main amplifier. And it is easy to cancel IMD on the min path and control IMD cancellation loop, compared with basic Feedforward Linear Power Amplifier. This feedback loop has the same effect of the Predistroter. So, This power amplifier was improved in IMD characteristics to add the effect of Predistroter to basic Feedforward amplifier. And the disigned power amplifier in this paper represented the 40dBm(10W) output and -55dBc 3rd IMD at center frequency 2.14GHz (@10MHz).

  • PDF

Reduction of Sound Radiated Power of Clamped Beams using Filtered Velocity Feedback Controllers (Filtered Velocity Feedback 제어기를 이용한 양단지지보의 음향파워 저감)

  • Shin, Chang-Joo;Hong, Chin-Suk;Jeong, Wei-Bong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.377-383
    • /
    • 2011
  • This paper reports the filtered velocity feedback (FVF) controller to reduce the acoustic power from clamped beams. The instability problem due to the non-collocated sensor/actuator configuration when using PZT actuator should be resolved. The roll-off property of the FVF controller at high frequency helps to alleviate the instability. The dynamics of clamped beams under forces and moments pair and the FVF controller are first formulated. The formulation of the sound radiated power is followed. The open loop transfer function (OLTF) synthesized with 100 modes is used to determine the stability of the control system. The control performance is finally estimated. The levels of the vibration and the sound radiated power are reduced in the wide band below the tuning mode of the FVF controller.

  • PDF