• Title/Summary/Keyword: Power factor improvement

Search Result 384, Processing Time 0.031 seconds

A Comparison Analysis of EMG according to Weight Class and Increase Record of Clean and Jerk Techniques Weightlifting in High School Female Weight Lifters (고교여자역도 선수들의 용상동작 수행 시 체급별 무게증가에 따른 EMG변화 비교 분석)

  • Park, Il-Bong;Yeo, Nam-Hwoeh;Kim, Jung-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.2
    • /
    • pp.105-114
    • /
    • 2008
  • The purpose of this study was to compare of muscles in clean and jerk techniques between 69kg class(n=3), 58kg class(n=3) in high school female weight lifters using EMG(electromyographic) system. EMG analysis were executed on 6 major muscles and dividing clean and jerk techniques into 6 phases. In that result, in the difference by weight, it was shown that EMG value increased gradually as the weight is raised of all muscles group & phases in 58kg class. In EMG signal scale by classes, it was shown that EMG signal scale didn't increase according to class & weight. In the result of this study, that EMG value was inconsistent in 69kg class is showing that the consideration of the technical factor together with muscle power has positive affect more on the performance improvement in the heavy class.

Organic photovoltaic cells using low sheet resistance of ITO for large-area applications

  • Kim, Do-Geun;Gang, Jae-Uk;Kim, Jong-Guk
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.5.1-5.1
    • /
    • 2009
  • Organic photovoltaic (OPV)cells have attracted considerable attention due to their potential for flexible, lightweight, and low-cost application of solar energy conversion. Since a 1% power conversion efficiency (PCE) OPV based on a single donor-acceptor heterojunction was reported by Tang, the PCE has steadily improved around 5%. It is well known that a high parallel (shunt)resistance and a low series resistance are required simultaneously to achieve ideal photovoltaic devices. The device should be free of leakage current through the device to maximize the parallel resistance. The series resistance is attributed to the ohmic loss in the whole device, which includes the bulk resistance and the contact resistance. The bulk resistance originated from the bulk resistance of the organic layer and the electrodes; the contact resistance comes from the interface between the electrodes and the active layer. Furthermore, it has been reported that the bulk resistance of the indium tin oxide (ITO) of the devices dominates the series resistance of OPVs for a large area more than $0.01\;cm^2$. Therefore, in practical application, the large area of ITO may significantly reduce the device performance. In this work, we investigated the effect of sheet resistance ($R_{sh}$) of deposited ITO on the performance of OPVs. It was found that the device performance of polythiophene-fullerene (P3HT:PCBM) bulk heterojunction OPVs was critically dependent on Rsh of the ITO electrode. With decreasing $R_{sh}$ of the ITO from 39 to $8.5\;{\Omega}/{\square}$, the fill factor (FF) of OPVs was dramatically improved from 0.407 to 0.580, resulting in improvement of PCE from $1.63{\pm}0.2$ to $2.5{\pm}0.1%$ underan AM1.5 simulated solar intensity of $100\;mW/cm^2$.

  • PDF

Electronic Ballast Design for Power Factor Improvement and Harmonic Reduction (역률개선 및 고조파 저감을 위한 전자식 안정기 설계)

  • Lee, Chung-Sik;Cho, Moon-Taek;Na, Seung-Kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.5
    • /
    • pp.483-489
    • /
    • 2014
  • Proposed electronic ballast circuit for harmonic reduction includes adding lossless snubber circuit to DC-DC converter. To get inverter for changing DC-AC, a lamp has been changed to equivalence resistance in the standard lamp voltage and current data, also inverter circuit has been interpreted by being changed to R, L, C equivalence circuit. Using converted equivalent circuit, the most suitable circuit constant which can satisfy the characteristics of fluorescent lamps has been decided on and finally designed. It could not only eliminate distortion waveform from pulsation frequency in inverter direct side current but also reduce considerably pulsation rate and switching loss by making input current of inverter discontinuous. The validity for the results of this study has been verified through the experiment to measure harmonic occurrence after applying a newly-manufactured product of electronic ballast to 40 W line tube style fluorescent lamps.

Dependence of Subthreshold Current for Channel Structure and Doping Distribution of Double Gate MOSFET (DGMOSFET의 채널구조 및 도핑분포에 따른 문턱전압이하 전류의존성)

  • Jung, Hak-Kee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.4
    • /
    • pp.793-798
    • /
    • 2012
  • In this paper, dependence of subthreshold current has been analyzed for doping distribution and channel structure of double gate(DG) MOSFET. The charge distribution of Gaussian function validated in previous researches has been used to obtain potential distribution in Poisson equation. Since DGMOSFETs have reduced short channel effects with improvement of current controllability by gate voltages, subthreshold characteristics have been enhanced. The control of current in subthreshold region is very important factor related with power consumption for ultra large scaled integration. The deviation of threshold voltage has been qualitatively analyzed using the changes of subthreshold current for gate voltages. Subthreshold current has been influenced by doping distribution and channel dimension. In this study, the influence of channel length and thickness on current has been analyzed according to intensity and distribution of doping.

Factors Influencing Implementation of OHSAS 18001 in Indian Construction Organizations: Interpretive Structural Modeling Approach

  • Rajaprasad, Sunku Venkata Siva;Chalapathi, Pasupulati Venkata
    • Safety and Health at Work
    • /
    • v.6 no.3
    • /
    • pp.200-205
    • /
    • 2015
  • Background: Construction activity has made considerable breakthroughs in the past two decades on the back of increases in development activities, government policies, and public demand. At the same time, occupational health and safety issues have become a major concern to construction organizations. The unsatisfactory safety performance of the construction industry has always been highlighted since the safety management system is neglected area and not implemented systematically in Indian construction organizations. Due to a lack of enforcement of the applicable legislation, most of the construction organizations are forced to opt for the implementation of Occupational Health Safety Assessment Series (OHSAS) 18001 to improve safety performance. Methods: In order to better understand factors influencing the implementation of OHSAS 18001, an interpretive structural modeling approach has been applied and the factors have been classified using matrice d'impacts croises-multiplication $appliqu{\acute{e}}$ a un classement (MICMAC) analysis. The study proposes the underlying theoretical framework to identify factors and to help management of Indian construction organizations to understand the interaction among factors influencing in implementation of OHSAS 18001. Results: Safety culture, continual improvement, morale of employees, and safety training have been identified as dependent variables. Safety performance, sustainable construction, and conducive working environment have been identified as linkage variables. Management commitment and safety policy have been identified as the driver variables. Conclusion: Management commitment has the maximum driving power and the most influential factor is safety policy, which states clearly the commitment of top management towards occupational safety and health.

A Study on the Improvement Policy for Entering Telecommunication Business of Private Network Holders (자가망 사업자의 통신사업 진입에 따른 개선 방안)

  • 이동식;김기문
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.8
    • /
    • pp.1200-1205
    • /
    • 2002
  • Construction of Private networks is becoming easier due to the openness of telecommunication market, rapidly developing telecommunication technology. The size of existing private networks is becoming huge which resulted in surplus of capacity of the networks. These trends will generate a problem of efficient use of national telecommunication resources and which will be a factor for the structure of domestic telecommunication market which will have a big impact on the existing telecommunication carriers. Therefore, national policy of private network issues should be considered along with the national efforts for the information infrastructure, control of telecommunication market, fairness of competition, strength Power of national competition. In this paper it will be suggested that the efficient policy on the issue of domestic private network, by analyzing present situation, status quo, laws, regulation and procedure for domestic private networks and comparing it with those of U.S.A, Japan, EU.

An Experimental Study on Performance of Energy Recovery Ventilation System (폐열회수 환기시스템의 성능에 관한 실험적 연구)

  • Kim, Young-Soo;Choi, Kwan-Soo;Kim, Il-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.445-450
    • /
    • 2012
  • At the limited space, the air conditioning may have difficult to control temperature or humidity for home use. Nowdays, the people reponse to temperature or humidity sensitively. This becomes the Indoor Air Quality (IAQ) is an important factor for comfortably. Heat recovery ventilator (HRV) is used for the solution of inconsistency between IAQ and power-saving. Also, the thermoelectric element is applied to HRV and compared with temperature efficiency and verifying the capacity of the system. To improve the temperature efficiency a single motor and thermoelectric element with the conductive guide vane is experimented. The results shows that it can save 23 W by using the single motor. The developed system of 250 CMH capacities with the thermoelectric element reveals the temperature efficiency improvement of 4.01% in cooling period and 2.98% in heating period compared to the conventional system.

Study on Efficiency Droop in a-plane InGaN/GaN Light Emitting Diodes

  • Song, Hoo-Young;Suh, Joo-Young;Kim, Eun-Kyu;Baik, Kwang-Hyeon;Hwang, Sung-Min;Yun, Joo-Sun;Shim, Jong-In
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.145-145
    • /
    • 2011
  • Light-emitting diodes (LEDs) based on III-nitrides compound semiconductors have achieved a high performance device available for display and illumination sector. However, the conventional c-plane oriented LED structures are still showing several problems given by the quantum confined Stark effect (QCSE) due to the effects of strong piezoelectric and spontaneous polarizations. The QCSE results in spatial separation of electron and hole wavefunctions in quantum wells, thereby decreasing the internal quantum efficiency and red-shifting the emission wavelength. Due to demands for improvement of device performance, nonpolar structure has been attracting attentions, since the quantum wells grown on nonpolar templates are free from the QCSE. However, current device performance for nonpolar LEDs is still lower than those for conventional LEDs. In this study, we discuss the potential possibilities of nonpolar LEDs for commercialization. In this study, we characterized current-light output power relation of the a-plane InGaN/GaN LEDs structures with the variation of quantum well structures. On-wafer electroluminescence measurements were performed with short pulse (10 us) and low duty factor (1 %) conditions applied for eliminating thermal effects. The well and barrier widths, and indium compositions in quantum well structures were changed to analyze the efficiency droop phenomenon.

  • PDF

Spindle-shaped Fe2O3 Nanoparticle Coated Carbon Nanofiber Composites for Low-cost Dye-sensitized Solar Cells (저비용 염료감응 태양전지를 위한 방추형 Fe2O3 나노입자가 코팅된 탄소나노섬유 복합체)

  • Oh, Dong-Hyeun;An, HyeLan;Koo, Bon-Ryul;Ahn, Hyo-Jin
    • Journal of Powder Materials
    • /
    • v.23 no.2
    • /
    • pp.95-101
    • /
    • 2016
  • Carbon nanofiber (CNF) composites coated with spindle-shaped $Fe_2O_3$ nanoparticles (NPs) are fabricated by a combination of an electrospinning method and a hydrothermal method, and their morphological, structural, and chemical properties are measured by field-emission scanning electron microscopy, transmission electron microscopy, X-ray diffraction, and X-ray photoelectron spectroscopy. For comparison, CNFs and spindle-shaped $Fe_2O_3$ NPs are prepared by either an electrospinning method or a hydrothermal method, respectively. Dye-sensitized solar cells (DSSCs) fabricated with the composites exhibit enhanced open circuit voltage (0.70 V), short-circuit current density ($12.82mA/cm^2$), fill factor (61.30%), and power conversion efficiency (5.52%) compared to those of the CNFs (0.66 V, $11.61mA/cm^2$, 51.96%, and 3.97%) and spindle-shaped $Fe_2O_3$ NPs (0.67 V, $11.45mA/cm^2$, 50.17%, and 3.86%). This performance improvement can be attributed to a synergistic effect of a superb catalytic reaction of spindle-shaped $Fe_2O_3$ NPs and efficient charge transfer relative to the one-dimensional nanostructure of the CNFs. Therefore, spindle-shaped $Fe_2O_3$-NP-coated CNF composites may be proposed as a potential alternative material for low-cost counter electrodes in DSSCs.

A research for improvement methods in the aspect of safety engineering through risk analysis of facilities for multiple use - Focused on escalator and passenger conveyors - (다중이용시설물 위험분석을 통한 안전공학적 개선 방안에 관한 연구 (에스컬레이터 및 수평보행기를 중심으로))

  • Kwon, Sun-Geol;Kim, Jin-Soo;Kim, Chang-Eun
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.31-40
    • /
    • 2013
  • For the matter of elevator, one of the multi-use facilities for unspecified public, the JIS has re-established and reformed to apply to the environment in South Korea for the past 20 years. In the aspect of safety assurance, it was inevitable to suggest improved measures. The government, Ministry of Public Administration and Security has secured the safety by enhancing the safety management functions in the elevator inspection standards and expanding its safety device measures. Further, the international inspection standard has been introduced, which is about unifying inspection standard system into the international standard code. In March 14th 2012, the international standard (EN) has been amended and fully announced. Escalator and passenger conveyor among lift devices have several common danger factor that cause safety accident. First, the accident caused by decreased braking power of brake. Second, the accident caused by the rate difference between handrail and tread-board. Third, the accident caused by defects of contraflow preventing device or carelessness inspection. Fourth, the accident caused by wet tread-board or wet floor of platform which makes passenger slip and fall. As the improvements to prevent and reduce these negligent accidents, the inspection list to check and methods should be subdivided and applied for each accident likelihood cause for safety management enhancement and safety assurance of existing escalator and passenger conveyors. The escalators and passenger conveyors without safety devices in existence should be obliged to modify the part of the system or install additional safety device. With making these measures obligations, it requires to improve the system to be suitable for the international inspection standard and to have measures to prevent safety accidents. It also needs to arrange improvements for skid accident of tread-board by the external environment factors such as snow and rain.