The Development of Flood Protection System for Pad Transformer using Pneumatic Pressure (공기압을 이용한 패드 변압기 침수방지용 장치 개발에 관한 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Bae, Seok-Myung;Jung, Chan-Oong;Lee, Jae-Yong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.1
    • /
    • pp.90-94
    • /
    • 2009
  • The inundation of substation and ground power equipment breaks out every summer season in low-lying downtown and low-lying shore by localized heavy rain, typhoon and tidal wave. For diminishing flood damage of electrical equipment in the root, flood protection system which is used the basic frame of Pad transformer is developed using pneumatic pressure. This system is established on pressure generator equipment and sensor of flooded level operates at flooding occurrence and is maintained a shutting tightly structure. The system is able to protect indraft water in Pad Transformer and supply the electricity at emergency(flooding). And we tested safety for insulation resistance at flooding and applying an electrical current. We estimate that loss cost which is caused by with flooding and the power failure will be diminished if it is addition to advances the reliability evaluation by setting an example.

Predictive Maintenance System using Condition Monitoring System of Hydro-turbine Generator (수차발전기 상태진단시스템을 이용한 예지보전체계)

  • Kim, Eung-Tae;Ko, Sung-Ho;Kim, Hyun;Jeong, Yong-Chae;Choi, Seong-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.453-456
    • /
    • 2007
  • The purpose of this study is to explain the importance of Vibration Monitoring Device by introducing an example of Predictive Maintenance System using Condition Monitoring System of Hydro-turbine generator. Confirming vibration of generation equipment is commissioning procedure during equipment completion for checking guaranteed items. Data from Generator output range are used to determine output band to continue the performance of equipment. The Vibration Monitoring System is not absolute method of maintenance, but if it is used well with expert, it will be visible, data-analyzed, scientific maintenance more than others. And also, Condition Monitoring System is very important for remote controlled small hydro-power plant although most of it is installed in Large hydro-power plant.

  • PDF

Predictive Maintenance System using Condition Monitoring System of Hydro-turbine Generator (수차발전기 상태진단시스템을 이용한 예지보전체계)

  • Kim, Eung-Tae;Ko, Sung-Ho;Kim, Hyun;Jeong, Yong-Chae;Choi, Seong-Pil
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.57-60
    • /
    • 2006
  • The purpose of this study is to explain the importance of Vibration Monitoring Device by introducing an example of Predictive Maintenance System using Condition Monitoring System of Hydro-turbine generator. Confirming vibration of generation equipment is commissioning procedure during equipment completion for checking guaranteed items. Data from Generator output range are used to determine output band to continue the performance of equipment. The Vibration Monitoring System is not absolute method of maintenance, but if it is used well with expert, it will be visible, data-analyzed, scientific maintenance more than others. And also, Condition Monitoring System is very important for remote controlled small hydro-power plant although most of it is installed in Large hydro-power plant.

  • PDF

Effect of Frost and Defrost on the Operating Characteristics of Refrigeration System (착상과 제상이 냉동장치의 운전특성에 미치는 영향)

  • Kim, J.D.
    • Journal of Power System Engineering
    • /
    • v.14 no.4
    • /
    • pp.5-10
    • /
    • 2010
  • This study was investigated the effect on operating characteristics of apparatus according to frosting and defrosting to develop of new defrosting equipment. The results showed as following. Frost was almost removed using the defrosting equipment with roll brush type that defrosting is possible under operating condition. Also, the temperature of compressor inlet, evaporator inlet and outlet showed higher value because of heat transfer resistance of cooling pipe frost comparing with defrosting condition. And the compressor work showed 10% lower and COP was presented 24% higher values than defrosting condition. Therefore, defrosting for cooling coil of refrigeration and low temperature storage was effected on operation and performance characteristics of equipment. This highly effects on real refrigeration apparatus which is operated in year-around.

Report on Predictive Maintenance System using Condition Monitoring System of Hydro-turbine Generator (수차발전기 상태진단시스템을 이용한 예지보전체계 사례)

  • Ko, Sung-Ho;Jeong, Yong-Chae;Choi, Seong-Pil;Kwack, Young-Kyun;Han, Seung-Yeul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.1
    • /
    • pp.29-34
    • /
    • 2010
  • The purpose of this study is to explain the importance of Vibration Monitoring Device by introducing an example of Predictive Maintenance System using Condition Monitoring System of Hydro-turbine generator. Confirming vibration of generation equipment is commissioning procedure during equipment completion for checking guaranteed items. Data from Generator output range are used to determine output band to continue the performance of equipment. The Vibration Monitoring System is not absolute method of maintenance, but if it is used well with expert, it will be visible, data-analyzed, scientific maintenance more than others. And also, Condition Monitoring System is very important for remote controlled small hydro-power plant although most of it is installed in Large hydro-power plant.

Diagnosis of Plasma Equipment using Neural Network and Impedance Match Monitoring

  • Byungwhan Kim
    • KIEE International Transaction on Systems and Control
    • /
    • v.2D no.2
    • /
    • pp.120-124
    • /
    • 2002
  • A new methodology is presented to diagnose faults in equipment plasma. This is accomplished by using neural networks as a pattern recognizer of radio frequency (rf) impedance match data. Using a match monitor system, the match data were collected. The monitor system consisted mainly of a multifunction board and a signal flow diagram coded by Visual Designer. Plasma anomaly was effectively represented by electrical match positions. Twenty sets of fault-symptom patterns were experimentally simulated with variations in process factors, which include rf source power, pressure, Ar, and $O_$2 flow rates. As an input to neural networks, two means and standard deviations of positions were used as well as a reflected power. Diagnostic accuracy was measured as a function of training factors, which include the number of hidden neurons, the magnitude of initial weights, and two gradients of neuron activation functions. The accuracy was the most sensitive to the number of hidden neurons. Interaction effects on the accuracy were also examined by performing a 2$^$4 full factorial experiment. The experiments were performed on multipole inductively coupled plasma equipment.

  • PDF

Electric power system effect investigation of large size digital signal accident thought in digital age (디지털시대의 대형사고의 전기적 영향 고찰)

  • Kang, Tae-Keun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.575-580
    • /
    • 2004
  • The latest equipment automatic Intelligence of digital base done large size equipment appear in succession. That run by voltage electric current(mA, mV, ${\mu}A,\;{\mu}V$) that outline is microscopic of action of accuracy large size equipment of this digital base is bulk. Have received influence that is great in river electric field by installment that use computer. Most of domestic working voltage from service entrance extra-high voltage and working voltage of commercial frequency 60Hz working voltage 220V that use our country outside 1 country in interior of 22.900V for semiconductor use computer use digital installment of appliance as well as various smalls of digital base, middle, large size that safety is these fine voltage electric current that is not enough direct admonition hundred vast damage give can. Also, already act in surge circle and impulse transient phenomena such as several thousands, myriads, strong bit error more than billions time to digital fine electronic circuit by mistake use of using electric facility system of system electric power.

  • PDF

Analysis of PD signals according to defects of the piezoelectric sensor (압전 센서 제작 및 결함에 따른 PD 분포 분석)

  • Jung, Hae-Eun;Park, Seong-Hee;Kang, Seong-Hwa;Lim, Kee-Joe;Lee, Kang-Won
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1480-1481
    • /
    • 2006
  • It is very difficult and dangerous to measure partial discharge from high voltage equipment in outdoor situation. But that is very important thing for preventing serious accidents from defects which originated in insulating degradation. This paper provides useful method to detect PD signals easily without any dangerous situation. Electric field sensor by the principle of capacitor detect PD signals without direct electrical connection between sensor and high power equipment and has very wide frequency range suitable for noise rejection. Electric field sensor and related circuit for processing PD signal showed good performance as a PD sensor when it is applied to simulated high power equipment generating PD pulse.

  • PDF

Reliability Evaluation Technique for Electrical Distribution Networks Considering Planned Outages

  • Hu, Bo;He, Xiao-Hui;Cao, Kan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1482-1488
    • /
    • 2014
  • The reliability evaluation of the electrical distribution networks (EDN) requires sufficient consideration of the effects of planned outages. The planned outages of the EDN can be divided, by outage models and their effects on the reliability into two major categories: by equipment and by feeder. After studying the characteristics of different categories of planned outages, this paper expands the classification of load points by outage time from 4 types to 7 types and defines corresponding reliability parameters for the different types. By using the section algorithm, this paper proposes a reliability evaluation technique of EDN considering equipment random failures and two categories of planned outages. The proposed technique has been applied to the RBTS-BUS6 test system and some practical EDNs in China. The study results demonstrate that the proposed technique is of higher practical value and can be used for evaluating the reliability performance of EDN more efficiently considering the planned outages.