• 제목/요약/키워드: Power distribution lines

검색결과 306건 처리시간 0.023초

배전설비도면에서의 자동인식 대상 영역 추출 방법 (An extraction technique of automatic recognizing regions on Power distribution facility map)

  • 김계영;금복희;이봉재;조선구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.2914-2916
    • /
    • 1999
  • A power distribution facility map is composed of distribution facility information regions, cadastral regions and grid lines. In this map, our goal is automatic interpretation of power distribution region. For the goal, it is the first work to extract the power distribution facility region. In this paper, we propose a method to extract power distribution facility regions. The proposed method is consist of two phases, binarization phase and extending phase. The first phase generate a power distribution facility image using threshold value. The image contains many part of power distribution facility regions, but not all. The second phase extends thinned image which is generated by appling thinning operator to the power distribution facility image.

  • PDF

22.9[kV] 지중배전계통케이블의 동심중성선에 흐르는 순환전류의 제거방안 및 효과 (An Elimination Method Of the Circulating Current Flowing into Coaxial-Neutral Lines in 22.9[kV] CNCV Underground Cable Systems)

  • 전명수;송중호
    • 조명전기설비학회논문지
    • /
    • 제22권2호
    • /
    • pp.107-113
    • /
    • 2008
  • 22.9[kV]-y 배전 방식은 지중 케이블로 전력을 공급하고 있으며 선로 운영상 배전케이블 선로의 동심중성선을 케이블 접속 구간마다 3선 일괄 접지하는 다중 접지방식을 채택하고 있다. 그러나 지중 배전 선로에서 각 상의 부하가 평형일 경우에도 동심중성선에는 부하 전류의 약 40[%](전력구)${\sim}$50[%](관로)의 동심중성선 순환 전류가 발생되고 있기 때문에, 순환전류로 인한 손실이 도체 손실의 76[%]에 달한다. 이러한 손실 전력으로 케이블의 내부온도가 상승되어 케이블의 허용전류 용량이 관로의 경우 20[%] 정도 감소하게 된다. 본 논문은 이와 같은 문제점을 해결하기 위하여 새로운 동심중성선 접지방식을 제안하고 있다. 새로운 방법은 동심중성선의 순환전류를 효과적으로 제거하고 있으며, 그 방안을 직접 계통망에서 적용시켜서 실측하여 본 결과, 그 타당성과 유용성을 확인하였다.

비접지 선박 3상 배전선로의 대지전압 벡터 모니터링 장치의 구성 (Configuration of a Module for Monitoring Voltages Between Power Lines and Hull Onboard Vessels Based on the Vector Diagram at 3 Phase Ungrounded Power Distribution System)

  • 최순만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권8호
    • /
    • pp.1111-1116
    • /
    • 2011
  • 비접지방식 선박에서의 접지 고장은 대지 임피던스의 불평형을 가져오고 대지전압을 상승시켜 감전이나 전기화재의 염려가 높아진다. 접지에 따른 이 같은 대지전압의 왜곡 상태는 전기안전의 측면에서 실시간으로 감시할 필요가 있으며 이 경우 대지전압의 측정치를 위상변화 감시가 가능한 벡터다이어그램으로 나타내는 것이 효과적이다. 대지전압의 상태는 중성점 위치에 의해 표시될 수 있다는 점에서 우선 측정된 대지전압 입력에 대해 벡터 평면의 중성점을 출력하는 연산과정과 알고리즘의 해석이 필요하다. 이를 토대로 본 연구에서는 매 샘플링 주기마다 대지전압을 입력하여 컴퓨터 모니터 상에 중성점과 벡터 대지전압을 출력하는 모듈을 구성한 후 실제 배전선로에서의 실험을 통해 제시한 장치의 적정성을 확인하였다.

배전선로 재폐로 최적 기준 산정에 관한 연구 (A Study on Determination of Optimal Reclosing Guideline on Distribution Lines)

  • 조재훈;이선정;문채주
    • 한국전자통신학회논문지
    • /
    • 제17권3호
    • /
    • pp.417-422
    • /
    • 2022
  • 선로를 따라 흐르는 전력흐름은 장기간에 걸쳐서 차단되지 않는 연속성을 갖는 것이 바람직하다. 배전선로에서 재폐로기의 최적 기준은 전력계통의 신뢰성을 개선하는 것으로 알려져 있으며, 배전계통에서 보호기능은 이러한 재폐로기의 수량과 위치가 매우 중요하다. 본 연구에서는 배전망 사고 동안 발생되는 손실을 줄이기 위하여 재폐로 동작 횟수를 포함한 보호기법의 사용 효과를 검토한다. 본 연구의 최종 목적은 표준 배전망에 대한 PSCAD/EMTDC의 모의데이터를 기반으로 사고전류 조건과 재폐로 동작 횟수를 결정하는 것이다. 피더의 보호기능인 재폐로기에서 동작횟수 결정은 배전망의 최적 운영과 신뢰성 확보에 도움이 된다.

배전용 변압기를 통한 저압전원선으로의 뇌서지 전파 (Propagation of Lightning Surges on Power AC Lines through Distribution Transformers)

  • 이복희;이수봉;이동문
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.468-471
    • /
    • 2002
  • A strong need to improve the quality of electric power is increased because of increasing use of the sensitive and small-sized electronic devices. The surges on the low-voltage ac power lines are induced by nearby lightning return strokes, and the facilities for HA, OA, FA, ME as well as computer are easily damaged by high-voltage transients. The behaviors of lightning surge characteristics transferred from the primary winding to the secondary winding in distribution transformers using a Marx generator were experimentally investigated. The transfer characteristics of lightning surge associated with a custom service ground of secondary side were also examined.

  • PDF

활선애자점검기의 개발 및 154kV 선로에의 적용 - 제1부 : 점검기 개발 (Development of Live-line Insulator Tester and Its Application to 154kV Power Lines - Part 1 : Tester Development)

  • 이재경;박준영;조병학;오기용
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.83-88
    • /
    • 2010
  • A new live-line insulator tester was developed to detect faulty insulators in 154kV power transmission lines. This paper is the first part of the two-part paper and deals with its tester development. The developed tester has the following characteristics. First, it automates parts of the insulator inspection process by using a sensor and an actuator, and secondly, it sustains its weight by itself, not by a lineman. Finally, it measures the insulation resistance of an insulator together with its distribution voltage to provide more information for its analysis and diagnosis. These leads to the improvement of its operation efficiency, measurement reliability and usability. Its effectiveness was validated by live-line field tests in actual power lines.

풍력발전단지의 계통연계 운전이 배전선 보호계전에 미치는 영향 (Influence of the Interconnected Wind farm on Protection for Distribution Networks)

  • 장성일;김광호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권3호
    • /
    • pp.151-157
    • /
    • 2003
  • Wind farm interconnected with grid can supply the power into a power network not only the normal conditions, but also the fault conditions of distribution network. If the fault happened in the distribution power line with wind fm, the fault current level measured in a relaying point might be lower than that of distribution network without wind turbine generator due to the contribution of wind farm. Consequently, it may be difficult to detect the fault happened in the distribution network connected with wind generator This paper describes the effect of the interconnected wind turbine generators on protective relaying of distribution power lines and detection of the fault occurred in a power line network. Simulation results shows that the current level of fault happened in the power line with wind farm depends on the fault impedance, the fault location. the output of wind farm. and the load condition of distribution network.

지중 배편케이블의 열화에 미치는 온수의 영향 (Effects of Hot Water on the Aging of URD Power Cables)

  • 한재홍;송일근;김주용;이병성;정종욱
    • 한국전기전자재료학회논문지
    • /
    • 제15권7호
    • /
    • pp.609-614
    • /
    • 2002
  • In this study, we investigated the effects of hot water on the aging of URD power cables due to the hot water ingress to power distribution lines. Hot water contacted and non-contacted cables extracted from 2 distribution lines were characterized by the measurement of oxidation induction time(OIT) and chemical structure. In OIT measurement, hot water contacted cables showed the shorter OIT than non-contacted ones. Especially, hot water contacted insulation layer near insulation shield showed the shortest OIT. In chemical structure analysis, the antioxidant content was decreased and the acid concentration was increased by hot water ingress. From this results, it can be concluded that the hot water ingress to power cable may be accelerate the aging by means of antioxidant consumption.

Matching Element Sensitivity Analysis for the Operation of a Dual-band Power Amplifier with CRLH Transmission Lines

  • Lee, Byeonguk;Kim, Changwook;Park, Youngcheol
    • 전기전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.1050-1055
    • /
    • 2018
  • In this paper, we analyzed the sensitivity of matching elements for the dual-band operation of a power amplifier with composite right/left-handed (CRLH) transmission lines. Metamaterial theory enables CRLH transmission to support arbitrary impedance matching at dual frequencies. In general, at sub-GHz range, the CRLH matching networks are commonly implemented with lumped elements, which are prone to manufacturing distribution. In order to reduce the effect from the distribution of element values in design, we suggest a method to analyze the sensitivity of matching elements from the performance aspect of power amplifiers. Based on the analysis, a 40dBm dual-band power amplifier operating at 0.7GHz and 1.5GHz is designed.

Dual-slope A/D 변환을 이용한 배전선 전압관리용 계측기 개발 (Development of the voltage management recorder using o dual-slope A/D converter for power distribution lines)

  • 손수국
    • 조명전기설비학회논문지
    • /
    • 제16권5호
    • /
    • pp.38-44
    • /
    • 2002
  • 본 논문에서는 배전선의 전압관리를 위한 계측시스템의 개발에 관하여 제안한다. 배전선 전압특성 및 측정상의 문제점이 분석되고, 전압관리를 위한 계측기의 기능에 대하여 제안한다. 노이즈 특성이 좋은 이중기울기(dual-slope) 방식의 A/D 컨버터를 적용하여 전압측정을 하는 알고리즘과 배전선 전압관리계기의 개발에 관하여 제안한다. IEEE 1159기준 분석에 따른 배전선의 정전 및 복귀 와 규정전압 초과 빈도 수 같은 전압변동 특성 등이 데이터베이스 제안에 의하여 분석된다. 실험을 통하여 그 편리성이 증명된다.