• 제목/요약/키워드: Power distribution lines

검색결과 306건 처리시간 0.032초

Maxwell 3D를 이용한 특고압 배전선로의 전계해석에 관한 연구 - I (A Study on the Electric Field Analysis of EHV Overhead Distribution Lines Using Maxwell 3D - I)

  • 서용필;박성원;김철환;원충연;남궁도;하복남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.847-849
    • /
    • 1996
  • As the power demands increases, one of the most important data is inside electric field of equipment in designing of insulators ami insulated wire for EHV distribution line. So far finite element analysis method is widely used to calculate this electric field. However as the shape of insulator becomes complicated, it is difficult in producing the mesh which suitable the shape. Especially, we have many difficulty that produce dense fine mesh only where the electric field is concentrated. Therefore in this paper, we perform the each conditional analysis of electric field using the Maxwell 3D Simulator to recover this defects. And we try to analyze electric field through the conventional 2 dimensional and 3 dimensional analysis in case of salt contamination on the surface of a insulator.

  • PDF

전원선의 전력분석을 이용한 주요정보 유출 가능성에 관한 연구 (A Study on Leakage of Critical Information via the Power Analysis of Power Lines)

  • 한경호;이성호
    • 전기학회논문지
    • /
    • 제63권11호
    • /
    • pp.1571-1574
    • /
    • 2014
  • In this paper, we propose a unidirectional transmission of critical information obtained by keyboard hacking or kernel and keyboard driver hacking even though the computer is not connected to the external network. We show the hacking can be attempted in the proposed method to show the way preventing such attempts in advance. Firewalls and other various methods are used to prevent the hacking from the external network but the hacking is also attempted in various ways to detour the firewall. One of the most effective way preventing from the hacking attack is physically disconnect the internal intranet systems from the external internet and most of the government systems, military systems and big corporate systems are using this way as on one of the protection method. In this paper, we show the feasibility of transmission of security codes, etc via the short message to the external network on the assumption that a hacking program such as Trojan Horse is installed on the computer systems separated from the external network. Previous studies showed that the letters on the monitor can be hijacked by electromagnetic analysis on the computer to obtain the information even though the system is not connected ti the network. Other studies showed that the security code hint can obtained by analyzing the power consumption distribution of CPU. In this paper, the power consumption distribution of externally accessible power line is analyzed to obtain the information and the information can be transmitted to the external network. Software controlling the CPU and GPU usage is designed to control the power supply of computer. The sensors such as the Rogowski coils can be used on the external power line to collect the data of power consumption change rates. To transmit the user password by short message, due to the capacitive components and the obstacle from other power supply, A very slow protocol are used.

지상변압기의 내부 보호장비 작동을 위한 MCA 보호협조에 대한 연구 (A study on Protective Coordination of MCA for Performing of the Pad Mounted Transformer's inside Protective Device)

  • 현승윤;김창환
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권1호
    • /
    • pp.5-7
    • /
    • 2022
  • KEPCO's plan is undergoing a trial operation to replace the open-loop section with ring main units configuration where underground distribution lines are installed, by linking the multi-way circuit breakers auto (MCA) on the power side of each pad-mounted transformer. However, ring main units application mentioned above may cause the ripple effects, when implementing the configuration without a study of protection coordination. Because ring main units with classical pre-set protection devices contribution in fault condition didn't consider yet. For the reliable ring main units operation, it is necessary to resolve several protection issues such as the protection coordination with substation side, prevention of the transformer inrush current. These issues can radically deteriorate the distribution system reliability Hence, it is essential to design proper protection coordination to reduce these types of problems. This paper presents a scheme of ring main units' configuration and MCA's settings of time-current curves to preserve the performance of protection coordination among the switchgears considering constraints, e.g. prevention of the ripple effects (on the branch section when a transformer failure occurs and the mainline when a branch line failure occurs). It was confirmed that the propagation of the failure for each interrupter segment could be minimized by applying the proposed TCC and the interrupter settings for the MCAs (branch, transformer). Further, it was verified that the undetected area of the distribution automation system (DAS) could be supplemented by having the MCA configurated ring main units operate first, instead of the internal protection equipment in the transformer such as the fuse, STP when a transformer failure occurs.

Design Considerations for a Distributed Generation System Using a Voltage-Controlled Voltage Source Inverter

  • Ko, Sung-Hun;Lee, Su-Won;Lee, Seong-Ryong;Naya, Chemmangot V.;won, Chung-Yuen
    • Journal of Power Electronics
    • /
    • 제9권4호
    • /
    • pp.643-653
    • /
    • 2009
  • Voltage-controlled voltage source inverter (VCVSI) based distributed generation systems (DGS) using renewable energy sources (RES) is becoming increasingly popular as grid support systems in both remote isolated grids as well as end of rural distribution lines. In VCVSI based DGS for load voltage stabilization, the power angle between the VCVSI output voltage and the grid is an important design parameter because it affects not only the power flow and the power factor of the grid but also the capacity of the grid, the sizing of the decoupling inductor and the VCVSI. In this paper, the steady state modeling and analysis in terms of power flow and power demand of the each component in the system at the different values of maximum power angle is presented. System design considerations are examined for various load and grid conditions. Experimental results conducted on a I KVA VCVSI based DGS prove the analysis and simulation results.

A Novel Detection Technique for Voltage Sag in Distribution Lines Using the Wavelet Transform

  • Ko, Young-Hun;Kim, Chul-Hwan;Ahn, Sang-Pil
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권3호
    • /
    • pp.130-138
    • /
    • 2003
  • This paper presents a discrete wavelet transform approach for determining the beginning and end times of voltage sags. Firstly, investigations in the use of some typical mother wavelets, namely Daubechies, Symlets, Coiflets and Biorthogonal are carried out and the most appropriate mother wavelet is selected. The proposed technique is based on utilizing the maximum value of Dl (at scale 1) coefficients in multiresolution analysis (MRA) based on the discrete wavelet transform. The results are compared with other methods for determining voltage sag duration, such as the Root Mean Square (RMS) voltage and Short Time Fourier Transform (STFT) methods. It is shown that the voltage sag detection technique based on the wavelet transform is a satisfactory and reliable method for detecting voltage sags in power quality disturbance analysis.

저압 전원선의 고조파 분석 (A Study on the Analysis of Harmonics on Low-voltage AC Lines)

  • 이복희;백영환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1885-1887
    • /
    • 2004
  • This paper presents the aspect and distribution of voltage and current harmonics being made at low voltage power systems. The voltage and current harmonics in power systems supplying various loads were monitored and analyzed. We have examined the results compared to advanced countries' harmonics control standards. As a result, the current harmonics were significantly greater than the voltage harmonics. In particular, the harmonics of currents flowing through loads with power switching electronics was pronounced. Also, the contents of current harmonics of street lamp circuits was about 30%, and it was decreased to 12.3% with the installation of scries reactor. On the whole, The measured results of voltage and current harmonics exceeds the regulation limits recommended by IEEE std 519-1992.

  • PDF

경부고속철도 주변의 60 Hz 전자계 분포 예측에 관한 연구경부고속철도 (Calculation of Power Frequency Electromagnetic Field Around the Kyeongbu High Speed Railways)

  • 김응식;명성호;이병윤;한인수;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1648-1650
    • /
    • 1997
  • The effects of power frequency electric and magnetic fields have been a source of concern for many years. Electromagnetic fields can pose a theat to both signal system of electrified railways and human body around railways. It is believed that, though the electromagnetic fields do no serious harm to human health, they do induce biological effects. This paper estimates the electromagnetic fields near Kyeongbu high speed railways with numerical data. The charge simulation method and surface charge method are used to calculate the electric field of 2 dimensional power distribution lines and rails and magnetic field is calculated on the base of Biot-Sarart's law.

  • PDF

직류 전기철도 에너지 절감방안 연구 (A Study on the Energy Saving Strategy in Electric Railway System)

  • 최병운;창상훈;김학련
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.676-681
    • /
    • 2005
  • The regenerative braked cars are being introduced in DC electric railway for energy saving. There has been a recent tendency for DC traction substation with regenerative inverter to increase in number. This is strongly related to the desire for effective utilization of electric power regenerated by DC electric cars and to the aim ensuring stable operation of regenerative braking system. The regenerative inverters DC power feed back from a generative car into AC power at a substation and supplies it to distribution lines. This paper suggest the result of characteristic analysis and capacity simulation. economical analysis in the regenerative inverter system.

  • PDF

22.9kV 다중접지 배전선로 자락고장으로 인한 과전압 유압사고 분석연구 (An Analysis Study on the Over-voltages by the Earth Fault in 22.9kV-Y Distribution Line)

  • 박상만;노황래;조성수;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3126-3128
    • /
    • 1999
  • In 22.9kV-Y overhead lines, if there is an earth fault, high fault current causes surge type over-voltages around this place. There are generally two types of earth faults. One is an earth fault which occurs when a voltage line falls to earth line. The other occurs when a voltage line directly falls to the earth. This study presents an analysis method on the earth fault.

  • PDF

재폐로에 의한 수용가측의 영향 (Impact of auto-reclosing on Customer systems)

  • 임성정;오정환;김재철;김일동;한경남;김영한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.740-742
    • /
    • 1996
  • This paper analyzes the Impact of customer system at the transients due to auto-reclosing on 22.9kV distribution lines. The various factors affecting this phenomena are analyzed In detail through parametric studies. These factors Include the fault current, fault location, reclosing angle, capacitor bank size, and customer load characteristics. The impacts of these transients on customer system are described and available to identify the optimal auto-reclosing scheme.

  • PDF