• Title/Summary/Keyword: Power comparison technique

Search Result 255, Processing Time 0.023 seconds

A Study on Forecasting Method for a Short-Term Demand Forecasting of Customer's Electric Demand (수요측 단기 전력소비패턴 예측을 위한 평균 및 시계열 분석방법 연구)

  • Ko, Jong-Min;Yang, Il-Kwon;Song, Jae-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • The traditional demand prediction was based on the technique wherein electric power corporations made monthly or seasonal estimation of electric power consumption for each area and subscription type for the next one or two years to consider both seasonally generated and local consumed amounts. Note, however, that techniques such as pricing, power generation plan, or sales strategy establishment were used by corporations without considering the production, comparison, and analysis techniques of the predicted consumption to enable efficient power consumption on the actual demand side. In this paper, to calculate the predicted value of electric power consumption on a short-term basis (15 minutes) according to the amount of electric power actually consumed for 15 minutes on the demand side, we performed comparison and analysis by applying a 15-minute interval prediction technique to the average and that to the time series analysis to show how they were made and what we obtained from the simulations.

Analysis Result for the Technical Development Reducing Standby Power in Domestic Major Electric Appliances : The Electricity Energy Saving Effect (국내 주요 가전제품의 대기전력저감기술 성과 분석 : 에너지절약 효과를 중심으로)

  • Lee, Eun-Young;Joung, Soon-Hee
    • Journal of Families and Better Life
    • /
    • v.27 no.4
    • /
    • pp.141-160
    • /
    • 2009
  • Recently, some policies for reducing standby power, which has quite an effect on electricity consumption, have been employed all over the world. This study surveys the present condition of standby power for major electric home appliances during three years and analyzes the result of technical development reducing standby power. It presents how the industry paid attention to applying the technique of reducing standby power to electric appliances and how it affects the product's energy efficiency. We survey the standby power's change for six items, which were selected from the major electric appliances available on the market. It analyzes the difference of standby power consumption between appliances with a standby power reducing technique and those without during the latest three years. The amount of the average standby power is also compared. The comparison data confirms that the industry's effort and application of reducing standby power contribution has contributed to increasing an appliance's energy efficiency. This study restricted the analyzed items to six appliances, which has been a low volunteered involvement in the standby power reducing program. It is important for reducing standby power consumption of appliances because it contributes to saving electric energy at home and abroad. The development of the standby power reducing technique is needed for more appliances. Along with the development of the standby power reducing technique in the industrial field, it also necessary for consumers to enlarge their understanding of standby power reduction for economic, social, and environmental values.

High frequency partial discharge measurement by metal foil electrode (박전극을 이용한 고주파 부분방전 측정 연구)

  • Kim, C.S.;Shin, D.S.;Lee, C.Y.;Kim, J.N.;Baek, J.H.;Kim, D.W.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1081-1083
    • /
    • 1999
  • The capacitive coupling technique has been used as conventional method for PD detection on the power cable line. Recently, however PD measurement using by high frequency is known to have an excellent sensitivity comparison with low frequency on-site. In this paper, the high frequency characteristic of two type of metal foil sensor was studied and the technique was proved to be more effective diagnostic method than conventional method for qualification of EHV cable and accessories.

  • PDF

Binary Nonlinear Joint Transform Correlator with Sinusoidal Iterative Filter in Spectrum Domain

  • Jeong, Man-Ho
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.357-362
    • /
    • 2010
  • The joint transform correlator (JTC) has been the best known technique for pattern recognition and identification. This paper proposes a new technique of fringe adjustment by adopting a sinusoidal amplitude-modulated iterative filter convolved with an interference fringe pattern in the joint power spectrum (JPS) domain. The comparison of our new technique and other techniques is presented to show that the newly proposed technique can successfully improve both the correlation peaks and the peak signal-to-noise ratio (PSNR). Simulated results of enhanced interference fringes are also presented.

A New Random SPWM Technique for AC-AC Converter-Based WECS

  • Singh, Navdeep;Agarwal, Vineeta
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.939-950
    • /
    • 2015
  • A single-stage AC-AC converter has been designed for a wind energy conversion system (WECS) that eliminates multistage operation and DC-link filter elements, thus resolving size, weight, and reliability issues. A simple switching strategy is used to control the switches that changes the variable-frequency AC output of an electrical generator to a constant-frequency supply to feed into a distributed electrical load/grid. In addition, a modified random sinusoidal pulse width modulation (RSPWM) technique has been developed for the designed converter to make the overall system more efficient by increasing generating power capacity and reducing the effects of inter-harmonics and sub-harmonics generated in the WECS. The technique uses carrier and reference waves of variable switching frequency to calculate the firing angles of the switches of the converter so that the three-phase output voltage of the converter is very close to a sine wave with reduced THD. A comparison of the performance of the proposed RSPWM technique with the conventional SPWM demonstrated that the power generated by a turbine in the proposed approximately increased by 5% to 10% and THD reduces by 40% both in voltage and current with respect to conventional SPWM.

Technical comparison between superconductive RSFQ logic circuits and silicon CMOS digital logics (초전도 디지털 RSFQ 논리회로와 실리콘 CMOS 회로와의 기술적 비교)

  • Cho, W.;Moon, G.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.1
    • /
    • pp.26-28
    • /
    • 2006
  • The development technique of digital logic using CMOS device is close reached several limitations These make technical needs that are ultra high speed superconductive systems based on CMOS silicon digital computing technique. Comparing digital logic based on silicon CMOS, the computing technique based on ultra high speed superconductive systems has many advantages which are ultra low power consumption, ultra high operation speed. etc. It is estimated that features like these increasingly improve the possibility of ultra low power and ultra superconductive systems. In this paper digital logics of current CMOS technique and RSFQ superconductive technique are compared with and analyzed.

Design and Implementation of Low-Power DWT Processor for JPEG2000 Compression of Medical Images (의료영상의 JPEG2000 압축을 위한 저전력 DWT 프로세서의 설계 및 구현)

  • Jang Young-Beom;Lee Won-Sang;Yoo Sun-Kook
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.2
    • /
    • pp.124-130
    • /
    • 2005
  • In this paper, low-power design and implementation techniques for DWT(Discrete Wavelet Transform) of the JPEG2000 compression are proposed. In DWT block of the JPEG2000, linear phase 9 tap and 7 tap filters are used. For low-power implementation of those filters, processor technique for DA(Distributed Arithmetic) filter and minimization technique for number of addition in CSD(Canonic Signed Digit) filter are utilized. Proposed filter structure consists of 3 blocks. In the first CSD coefficient block, every possible 4 bit CSD coefficients are calculated and stored. In second processor block, multiplication is done by MUX and addition processor in terms of the binary values of filter coefficient. Finally, in third block, multiplied values are output and stored in flip-flop train. For comparison of the implementation area and power dissipation, proposed and conventional structures are implemented by using Verilog-HDL coding. In simulation, it is shown that 53.1% of the implementation area can be reduced comparison with those of the conventional structure.

Economic Life Assessment of Power Transformer using HS Optimization Algorithm (HS 최적화 알고리즘을 이용한 전력용 변압기의 경제적 수명평가)

  • Lee, Tae-bong;Shon, Jin-geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.3
    • /
    • pp.123-128
    • /
    • 2017
  • Electric utilities has been considered the necessity to introduce AM(asset management) of electric power facilities in order to reduce maintenance cost of existing facilities and to maximize profit. In order to make decisions in terms of repairs and replacements for power transformers, not only measuring by counting parts and labor costs, but comprehensive comparison including reliability and cost is needed. Therefore, this study is modeling input cost for power transformer during its entire life and also the life cycle cost (LCC) technique is applied. In particular, this paper presents an application of heuristic harmony search(HS) optimization algorithm to the convergence and the validity of economic life assessment of power transformer from LCC technique. This recently developed HS algorithm is conceptualized using the musical process of searching for a perfect state of harmony. It uses a stochastic random search instead of a gradient search so that derivative information is unnecessary. The effectiveness of the proposed identification method has been demonstrated through an economic life assessment simulation of power transformer using HS optimization algorithm.

Comparison with modulation method for PLC (전력선 통신을 위한 변조 방식의 특성 비교)

  • Seo, Jong-Wan;Lee, Jung-Hoon;Lee, Jong-Joo;Jung, Ho-Sung;Shin, Myung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.193-195
    • /
    • 2000
  • Power Line Communication(PLC) is the old technique. But it's worked in a very low spees. Developing of wireless communication technique, PLC is adopted these tech, for high speed communication. However, Power line environment differ from wireless environment. This paper survey modulation techniques and find the best modulation technique which is appropriate for power line environment.

  • PDF

Study of concrete de-bonding assessment technique for containment liner plates in nuclear power plants using ultrasonic guided wave approach

  • Lee, Yonghee;Yun, Hyunmin;Cho, Younho
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1221-1229
    • /
    • 2022
  • In this work, the guided wave de-bonding area-detecting technique was studied for application to containment liner plates in nuclear power plant areas. To apply this technique, an appropriate Lamb wave mode, symmetric and longitudinal dominance, was verified by the frequency shifting technique. The S0 2.7 MHz mm Lamb wave mode was chosen to realize quantitative experimental results and their visualization. Results of the bulk wave, longitudinal wave mode, and comparison experiments indicate that the wave mode was able to distinguish between the de-bonded and bonded areas. Similar to the bulk wave cases, the bonded region could be distinguished from the de-bonded region using the Lamb wave approach. The Lamb wave technique results showed significant correlation to the de-bonding area. As the de-bonding area increased, the Lamb wave energy attenuation effect decreased, which was a prominent factor in the realization of quantitative tomographic visualization. The feasibility of tomographic visualization was studied via the application of Lamb waves. The reconstruction algorithm for the probabilistic inspection of damage (RAPID) technique was applied to the containment liner plate to verify and visualize the de-bonding condition. The results obtained using the tomography image indicated that the Lamb wave-based RAPID algorithm was capable of delineating debonding areas.