• Title/Summary/Keyword: Power capacitor

Search Result 1,923, Processing Time 0.037 seconds

A Study on the Power Factor Correction and Harmonics Reduction of Capacitor Banks installed at Customers (수용가에 설치된 캐패시터 뱅크의 역률개선 및 고조파 저감에 관한 연구)

  • Kim, Kyung-Chul;Choi, Hyoung-Bumb
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.8
    • /
    • pp.12-17
    • /
    • 2008
  • Most power system loads and delivery apparatus are inductive in nature and therefore operate at a lagging power factor. Applying capacitor banks to a customer will result in a power factor correction and other benefits such as VAR support, increased voltage, reduced power losses, and reduced billing charges. Also there can be power quality problems as a result of adding capacitor banks. The most common are harmonics. This paper provides an in depth analysis on the power factor correction and harmonics reduction of capacitor bank installed at a customer. The EDSA program was used as a simulation tool for the case study.

Dynamic Performance Comparison of Various Combination of Reactive Power Compensators (조상설비 조합에 따른 정태적 특성 및 동태적 특성 비교)

  • Jang Gilsoo;Lee Byongjun;Kwon Sae-hyuk;Kang Sanggyun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.4
    • /
    • pp.159-164
    • /
    • 2005
  • Various compensators are installed into the power system to operate the system economically and stably by maximizing the availability of utilities and power transmission capability. Fixed Capacitor(FC), Mechanical Switched Capacitor(MSC), and FACTS(Flexible AC Transmission Systems) are used to regulate voltage and power flow of the system. When a disturbance occurs in the power system, the Fixed Capacitor operates dependently on the voltage of the power system and cannot change the amount of installation automatically. But compared to other equipment, the Fixed Capacitor is more economical due to its low cost. Since MSC can change the amount of installation according to the state of the power system, operates more effectively than the Fixed Capacitor. FACTS have fast dynamic performance for the transient condition, but the cost is high. Therefore, it is needed to develop an optimized installation planning for the reactive power compensators by considering their dynamic performance and cost. In this paper, an optimized compensator combination and the proposed scheme is proposed and it is applied to KEPCO system in order to show its capabilities.

Development of High Voltage and High Energy Density Capacitor for Pulsed Power Application (펄스파워용 고전압 고에너지밀도 커패시터 개발)

  • 이병윤;정진교;이우영;박경엽;이수휘;김영광
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.5
    • /
    • pp.203-210
    • /
    • 2003
  • This paper describes high voltage and high energy density capacitor developed for pulsed power applications. The rated voltage of the developed capacitor is DC 22 [kV], the capacitance is 206 [$\mu$F] and the energy density is about 0.7 [kJ/kg]. Polypropylene film and kraft paper were used as the dielectrics. The ratio of the thickness of each dielectric material which consists of the composite dielectric structure, stacking factor and the termination method were determined by the charging and discharging tests on model capacitors. In terms of energy density, the developed capacitor has higher energy density compared with the products of foreign leading companies. In addition, it has been proved that the life expectancy can be more over 2000 shots through the charging and discharging test. The voltage reversal factor was 20%. This capacitor can be used as numerous discharge applications such as military, medical, industrial fields.

Control of Motor Drives Fed by PFC Circuits without DC-Link Electrolytic Capacitors

  • Kim, Kwang-Man;Kim, Eung-Ho;Choi, Jong-Woo
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1067-1074
    • /
    • 2018
  • This paper presents a control method for variable-speed motor drives that do not use a DC-link electrolytic capacitor. The proposed circuit consists of a power factor correction converter for boosting the DC-link voltage, an inverter for driving the motor, and a small DC-link film capacitor. By employing a small DC-link capacitor, the proposed circuit that is small, and a low cost and weight are achieved. However, because the DC-link voltage varies periodically, the control of the circuit is more difficult than that of the conventional method. Using the proposed control method, an inverter can be controlled reliably even when the capacitance of the DC-link capacitor is very small. Experiments are performed using a 1.5-kW inverter with a $20-{\mu}F$ DC-link capacitor, and the experimental results are analyzed thoroughly.

A Study on Dynamic Stability of HVDC System Type which may be Applied the Jeju AC Network (제주계통에 적용 가능한 유형별 HVDC 시스템의 동적 안정도 연구)

  • Kwon, Young-Hun;Kim, Yong-Hak;Kim, Chan-Ki;Choy, Young-Do
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.270-277
    • /
    • 2008
  • Capacitor Commutated Converter HVDC system is required the small reactive power. It has the advantage of an application to the week grid because the firing angle ${\alpha}$ can be increased to a value well beyond $180^{\circ}$. In this paper, The three HVDC converter arrangements which are the CCC(Capacitor Commutated Converter) and the CSCC(Controlled Series Capacitor Convertor) and Conventional Converter are compared the dynamic character. and it find that the CCC HVDC is operating with more reliability. The simulation was conducted to the PSCAD/EMTDC.

Series-Parallel Connected Capacitor Type Boost Converter for a Single-Phase SRM

  • Lee, Dong-Hee;Liang, Jiang;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.388-395
    • /
    • 2010
  • An active boost converter for a single phase SRM using series-parallel connected capacitors is proposed in this paper. The proposed active boost converter has two diodes and one power switch with an anti-parallel diode and one additional boost capacitor. The additional boost capacitor could be series or parallel connected to the dc-link capacitor to produce proper excitation and demagnetization voltage. The proposed active boost converter can easily achieve a fast excitation and demagnetization from the capacitor connection. In this paper, series and parallel connected converters are reviewed, and the detailed operating modes as well as the voltage characteristics of the proposed converter are analyzed. The simulation and experimental results shows the effectiveness of the proposed active boost converter.

A Simple Capacitance Estimation Method for Failure Diagnosis of DC Link Electrolytic Capacitor in Power Converters (전력변환기에 대한 직류링크 커패시터의 고장진단을 위한 간단한 용량 추정 기법)

  • Shon, Jin-Geun;Kim, Dong-Joon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.378-383
    • /
    • 2010
  • Due to the large capacity and low cost, DC link electrolytic capacitors with of energy storage and voltage regulation are used for almost all types of power converter as the DC/AC inverter or DC/DC converter. Electrolytic capacitor, which is the most of the time affected by the aging effect, plays very important role for the power converter system quality and reliability. Therefore, this paper proposes a simple method to estimate the capacitance variation of an electrolytic capacitor in order to analyze the internal characteristic decrease and worn-out state of an electrolytic capacitor. Simulation results by using capacitor storage energy computation show the validity of the proposed capacitance estimation method.

A Study on the Characteristic of Capacitor Current by Voltage Harmonics (전압 고조파에 의한 커패시터 전류 특성 해석)

  • Kim, Jong-Gyeum;Kim, Sung-Hyun;Kim, Il-Jung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.148-153
    • /
    • 2009
  • As the increasing of non-linear load, we have a growing interest in power quality. Power quality has come to the voltage quality. Voltage harmonics consist in at the PCC by the non-linear load. Capacitor is generally used for the power compensation and as the passive filter by the serial connection with reactor. Capacitor has low impedance as the frequency increases, so easily fall down by the harmonic component of non-linear load. Small voltage of low-order acts on quite a few at the capacitor by the current increase. In this paper, we measured the magnitude and angle of voltage at the PCC and calculated under the same condition. we checked out that lower voltage of higher order produces current magnification.

Low-cost crowbar system and protection scheme in capacitor bank module (커패시터 뱅크 모듈 구성에 있어서 경제적인 크로바 시스템과 보호회로)

  • Rim, Geun-Hie;Cho, Chu-Hyun;Lee, Hong-Sik;Pavlov, E.P.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2089-2091
    • /
    • 2000
  • Pulsed power systems consist of a capacitor bank, an isolated high-voltage charging power-supply, high-current bus-work for charging and discharging and a control system. In such pulsed power systems, the operating-lifetime of the capacitors is closely dependent on the voltage reversal. Hence, most capacitor-discharging systems includes crowbar circuits. The crowbar circuit prevents the capacitor recharging with reverse voltage. Usually it consists of crowbar resistors and high pulse-current diode-stacks connected in series. The requirements for the diode-stacks are fast-recovery time and high-voltage and large-current ratings, which results in the high cost of the pulsed-power system. This paper presents a protection scheme of a charging and discharging system of a 500kJ capacitor bank using a low-cost crowbar circuit and safety-fuses.

  • PDF

On-line Remote Diagnosis System for DC Bus Capacitor of Power Converters Using Zigbee Communication (Zigbee통신을 이용한 전력변환기기의 DC Bus 커패시터의 온라인 원격 고장진단 시스템)

  • Chung, Wan-Sup;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.1
    • /
    • pp.29-34
    • /
    • 2015
  • DC bus electrolytic capacitors are used in variety of equipments as smoothing element of the power converters because it has high capacitance for its size and low price. It is responsible for frequent breakdowns of many static converters and inverter drive systems. Therefore it is important to diagnosis monitoring the condition of an electrolytic capacitor in real-time to predict the failure of power converter. In this paper, the on-line remote diagnosis monitoring system for DC BUS electrolytic capacitors of power converter using low-cost type Zigbee communication modules is developed. To estimate the health status of the capacitor, the equivalent series resistor(ESR) of the component has to be determined. The capacitor ESR is estimated by using RMS computation using AC coupling method of DC link ripple voltage/current. The Zigbee communication-based experimental results show that the proposed remote DC capacitor diagnosis monitoring system can be applied to DC/DC converter and UPS successfully.