• 제목/요약/키워드: Power burden

검색결과 344건 처리시간 0.022초

Human Error Identification based on EEG Analysis for the Introduction of Digital Devices in Nuclear Power Plants

  • Oh, Yeon Ju;Lee, Yong Hee
    • 대한인간공학회지
    • /
    • 제32권1호
    • /
    • pp.27-36
    • /
    • 2013
  • Objective: This paper describes an analysis of electroencephalography(EEG) signals to identify human errors during using digital devices in nuclear power plants(NPPs). Background: The application of an advanced main control room(MCR) has accompanied with lots of changes in different forms and features by virtue of new digital technologies. The characteristics of these digital technologies and devices provide several opportunities for the use of interface management. It can integrate into a compact single workstation in an advanced MCR, allowing workers to operate the plant with minimum physical burden under any operating condition. However these devices may introduce new types of human errors, and thus we need a means to assess and prevent such errors especially those related to digital devices. Method/Conclusion: The EEG data are relatively objective, and thus we introduce several measures to EEG analysis for obtaining the feasibility of human error identification. Application: This study may support to ensure the safety when applying digital devices in NPPs.

An Intelligent Human-Machine Interface for Next Generation Nuclear Power Plants

  • Park, Seong-Soo;Park, Jin-Kyun;Hong, Jin-Hyuk;Chang, Soon-Heung;Kim, Han-Gon
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.191-196
    • /
    • 1995
  • The intelligent human-machine interface (HMI) has been developed to enhance the safety and availability of a nuclear power plant by improving operational reliability The key elements of the HMI are the large display panels which present synopsis of the plant status and the compact, digital work stations for the primary operator control and monitoring functions. The work station consists of four consoles such as a dynamic alarm console (DAC), a system information console (SIC), a computerized operating-procedure console (COC), and a safety related information console (SRIC). The DAC provides clean alarm pictures, in which information overlapping is excluded and alarm impacts are discriminated, for quick situation awareness. The SIC covers a normal operation by offering all necessary plant information and control functions. In addition, it is closely linked with the DAC and the COC to automatically display related system information under the request of these consoles. The COC aids the operator with proper emergency operation guidelines so as to shutdown the plant safely, and it also reduces his physical/mental burden by automating the operating procedures. The SRIC continuously displays safety related information to allow the operator to assess the plant status focusing on plant safety. The proposed HMI has been validated and demonstrated with on-line data obtained from the full-scope simulator for Yonggwang Units 1,2.

  • PDF

다공성 세라믹(${\alpha}-Al_{2}O_{3}$)를 이용한 지중 매설형 기준전극 (The Development of Buried Type Reference Electrode Using Porous Ceramic(${\alpha}-Al_{2}O_{3}$))

  • 배정효;하윤철;하태현;이현구;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.145-147
    • /
    • 2005
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential due to stray current of subway system. So, we have developed the Real-time Wireless Remote Monitoring System for Stray Current of Subway System. In this system, the permanent buried type reference electrode is necessary. In this paper, results of development of buried type reference electrode using porous ceramic$({\alpha}-Al_{2}O_{3})$ are presented.

  • PDF

전력계통의 페이저 측정기 최적배치 (Optimal Placement of the Phasor Measurement Units in Power System)

  • 김재훈;조기선;김회철;신중린
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권7호
    • /
    • pp.313-322
    • /
    • 2000
  • This paper presents optimal placement of minimal set of Phasor Measurement Units (PMU's) and observability analysis of the network with PMU's. In order to find a observable system, a symbolic method which directly assigns an appropriate symbol for measurement or pseudo-measurement to every entry of node-branch incidence matrix is proposed. It is much simpler and easier to analyze the observability of the network with PMU's than the conventional ones. For the optimal PMU placement problem, two approaches which are based on a modified Simulated-Annealing (SA) method and a Direct Combination method are proposed. Some case studies with IEEE sample system are made to show the performance of the proposed methods are almost alike and more effective than the conventional simulated-annealing method. It is also shown that the Direct Combination method is more effective than the modified simulated-annealing one in the sense of computation burden. The results of this study showed also that the accuracy of power system estimation and system observability can be improved the proposed PMU placements.

  • PDF

Characteristics of the magnetic flux-offset type FCL by switching component

  • Jung, Byung-Ik;Choi, Hyo-Sang
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권2호
    • /
    • pp.18-20
    • /
    • 2016
  • The study of superconducting fault current limiter (SFCL) is continuously being studied as a countermeasure for reducing fault-current in the power system. When the fault occurred in the power system, the fault-current was limited by the generated impedance of SFCLs. The operational characteristics of the flux-offset type SFCL according to turn ratios between the primary and the secondary winding of a reactor were compared in this study. We connected the secondary core to a superconductor and a SCR switch in series in the suggested structure. The fault current in the primary and the secondary winding of the reactor and the voltage of the superconductor on the secondary were measured and compared. The results showed that the fault current in the load line was the lowest and the voltage applied at both ends of the superconductor was also low when the secondary winding of the reactor had lower turn ratio than the primary. It was confirmed based on these results that the turn ratio of the secondary winding of the reactor must be designed to be lower than that of the primary winding to reduce the burden of the superconductor and to lower the fault current. Also, the suggested structure could increase the duration of the limited current by limiting the continuous current after the first half cycle from the fault with the fault current limiter.

자속구속리액터의 철심조건에 따른 특성 (Characteristics under the Iron Core Conditions of the Flux-lock Reactor)

  • 이나영;최효상;박형민;조용선;남긍현;한태희;임성훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.875-876
    • /
    • 2006
  • Superconducting fault currents(SFCLs) are expected to improve not only reliability but also stability of power systems. The analysis on current limiting operations of the flux-lock type SFCL, which consists of a flux-lock reactor wound an iron core and a YBCO thin film, was compared the open-loop with the closed-loop iron core of the subtractive polarity winding. In the SFCL, operation characteristics could be controlled by adjusting the inductances and the winding directions of the coils, then magnetic field induced in the iron core. The current limiting characteristics under the same experimental conditions were generated regardless of the iron core conditions. We confirmed that capacity of the SFCL was increased effectively by the closed-loop iron core. However, the power burden of the system could be lowered by the open-loop iron core.

  • PDF

Simplified Model Predictive Control Method for Three-Phase Four-Leg Voltage Source Inverters

  • Kim, Soo-eon;Park, So-Young;Kwak, Sangshin
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2231-2242
    • /
    • 2016
  • A simplified model predictive control method is presented in this paper. This method is based on a future reference voltage vector for a three-phase four-leg voltage source inverter (VSI). Compared with the three-leg VSIs, the four-leg VSI increases the possible switching states from 8 to 16 owing to a fourth leg. Among the possible states, this should be considered in the model predictive control method for selecting an optimal state. The increased number of candidate switching states and the corresponding voltage vectors increase the calculation burden. The proposed technique can preselect 5 among the 16 possible voltage vectors produced by the three-phase four-leg voltage source inverters, based on the position of the future reference voltage vector. The discrete-time model of the future reference voltage vector is built to predict the future movement of the load currents, and its position is used to choose five preselected vectors at every sampling period. As a result, the proposed method can reduce calculation load by decreasing the candidate voltage vectors used in the cost function for the four-leg VSIs, while exhibiting the same performance as the conventional method. The effectiveness of the proposed method is demonstrated with simulation and experiment results.

활동중심의 협력학습을 통한 고등학교 수학수업의 개선사례 연구 (A Learning Model for Improvement in Learning Mathematics through Cooperative Group Activities in High School)

  • 한만영;박달원
    • 한국학교수학회논문집
    • /
    • 제7권1호
    • /
    • pp.103-120
    • /
    • 2004
  • 본 논문은 입시교육에 치중함으로써 흥미나 자신감을 잃고 학습 결손이 누적되어 학습을 포기하는 학생들이 속출하는 인문계 고등학교에서 수학에 대한 인식 및 이해실태를 정확히 진단한 후, 도출된 문제점을 해결할 수 있는 방안으로 활동중심의 교수-학습 방법을 구안ㆍ적용하였다. 설문조사와 참여관찰평가, 인터뷰 자료의 분석 결과, 수학수업의 긍정적 변화를 알 수 있었다.

  • PDF

농축인자법에 의한 유도방출 기준 설정 (Determination of Derived Release Limits by the Concentration Factor Method)

  • Byung Woo Kim;Byeung Kyu Kim;Jeong Ho Lee
    • Nuclear Engineering and Technology
    • /
    • 제17권4호
    • /
    • pp.267-278
    • /
    • 1985
  • 원자력발전소로부터 배출되는 방사성물질에 의한 피폭선량을 규제하는데 있어 몇 가지 종류들의 방식들이 적용되어 왔다. ICRP에 의해 권고된 일차 선량 당량 제한치가 가장 근본적인 것이다. 일차 제한치가 직접 적용될 수 없을 때 외부 피폭의 경우 선량당량 지표가 내부피폭의 경우 최대허용농도, 연섭취 제한치 흑은 유도대기 농도 및 최대 신체 부하량 등이 이용되어 왔다. 그러나 이 값들은 실제 배출량을 제어하는 견지에서 바로 사용할 수 없어 유도방출 기준치를 구하게 된다. 본 연구에선 월성 원자력발전소에 대해 고려되는 특정환경들 사이의 전달속도가 시간에 독립적인, 장기성 농축인자 방식으로 방출속도의 유도 제한치를 구하였다.

  • PDF

압전 변압기를 이용한 멀티 램프 구동용 인버터 설계 (Design of Inverter for Driving the Multi-lamp using an Piezoelectric Transformers)

  • 조성구;임영철;양승학
    • 전력전자학회논문지
    • /
    • 제10권2호
    • /
    • pp.130-137
    • /
    • 2005
  • LCD는 광변조기능을 가지는 수광 소자로서 발광원인 백라이트를 필요로 하는데 일반적으로 냉음극 방전램프(CCFL: Cold Cathode Fluorescent Lamp)가 사용된다. 기존의 권선형 변압기를 이용한 인버터를 구성하여 멀티램프를 구동하고 있지만 이는 코어나 권선 손실에 의한 효율 저하와 부피나 중량의 증가, 그리고 과열에 의한 화재의 위험성을 가지고 있다. 이러한 문제들을 해결하기 위해 본 논문에서는 압전 변압기를 이용한 멀티램프 구동용 인버터를 설계 지침에 따라 구성하였다. 인버터 하나로 압전 변압기를 병렬로 연결하는 방식을 이용하였고, 또한 전류 부담이 적은 외관 전극 형광 램프(EEFL: External Electrode Fluorescent Lamp)를 이용한 멀티램프 구동 방법이 압전 인버터에 적용 가능한지를 확인하였다.