• Title/Summary/Keyword: Power apparatus

Search Result 621, Processing Time 0.03 seconds

A Study on the 3-phase 13.2 kV Solid State Transformer for the DC Distribution (직류 배전망 연계를 위한 3상 13.2kV급 반도체 변압기 시스템에 대한 연구)

  • Jeong, Dong-Keun;Yun, Hyeok-Jin;Park, Si-Ho;Kim, Ho-Sung;Kim, Myoung-Ho;Ryu, Myung-Hyo;Baek, Ju-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.5
    • /
    • pp.315-324
    • /
    • 2021
  • A solid state transformer (SST) that can interface an MVAC of three-phase 13.2 kV and a 1.5 kV DC distribution. SST consists of an AC/DC converter and a DC/DC converter with a high-frequency isolation transformer (HFIT). The AC/DC converter consists of cascaded NPC full-bridge to cope with the MVAC. The DC/DC converter applies a quad active bridge (QAB) topology to reduce the number of the HFIT. Topology analysis and controller design for this specific structure are discussed. In addition, the insulation of HFIT used in DC/DC converters is considered. The discussion is validated using a 300 kVA three-phase SST prototype.

A Prediction Scheme for Power Apparatus using Artificial Neural Networks (인공신경망을 이용한 수전설비 고장 예측 방법)

  • Ki, Tae-Seok;Lee, Sang-Ho
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.6
    • /
    • pp.201-207
    • /
    • 2017
  • Failure of the power apparatus causes many inconveniences and problems due to power outage in all places using power such as industry and home. The main causes of faults in the Power Apparatus are aging, natural disasters such as typhoons and earthquakes, and animals. At present, the long high temperature status is monitored only by the assumption that a fault occurs when the temperature of the power apparatus becomes higher. Therefore, it is difficult to cope with the failure of the power apparatus at the right time. In this paper, we propose a power apparatus monitoring system as an efficient countermeasure against general faults except for faults caused by sudden natural disasters. The proposed monitoring system monitors the power apparatus in real time by attaching a thermal sensor, collects the monitored data, and predicts the failure using the accumulated information through learning using the artificial neural network. Through the learning and experimentation of artificial neural network, it is shown that the proposed method is efficient.

Development of A Test Apparatus for Control Rod Drive Mechanism in Nuclear Power Plants

  • Kim, Choon-Kyung;Cheon, Jong-Min;Lee, Jong-Moo;Kim, Seog-Joo;Kwon, Soon-Man
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1732-1735
    • /
    • 2003
  • In this paper, a DSP-based test apparatus for Control Rod Drive Mechanism (CRDM) that is used in nuclear power plants is described. Using this apparatus, we can test the mechanical and electrical characteristics of CRDM and obtain some information about how to improve the CRDM further and how to design a power controller to actuate the CRDM. Since firing angles can be directly applied to the gate-drive circuits of thyristors in the power controller by using this apparatus, the maximum and minimum values of firing angles within available limits are easily measured. Also step-current inputs help us investigate each coil's response characteristics. Therefore, we can easily find the range of control gains which enables a stable CRDM operation in insertion and withdrawal actions at high speed, mid speed, and low speed. Since this apparatus has a test mode in which an insertion or withdrawal action is divided into several phases so that the current command for each phase is given step by step, we may judge whether the CRDM works as expected or not. We also describe a fault detection capability of the test apparatus for the power controller by using discrete Fourier transform.

  • PDF

Design and Analysis of an Axial Flux Magnet for Magnetic Levitation System. (자기부상용 증축형 전자석의 설계 및 특성 해석)

  • Kang, Do-Hyun;Shin, Pan-Seok;Kim, Yong-Joo;Cho, Yun-Hyun;Park, Do-Young
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.63-67
    • /
    • 1990
  • An axial flux magnet for a magnetic levitation system is designed and analysed by finite element simulations. The results are compared with those of experiment in order to verify the analysing method. Lift force, air gap flux density and temperature characteristics of the magnet showed fairly good agreement with each other.

  • PDF

System Loss Improvement through Proper Location of Active and Reactive Power Apparatus (유무효전력설비의 적소투입을 통한 전력손실개선)

  • 이상중
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.77-80
    • /
    • 2000
  • This paper presents a method for improving the power loss through optimal location of active or reactive power apparatus. The paper introduces the los sensitivities which imply the variation of the power loss with respect to the incremental bus power P, Q and uses them as the investment information for the active and reactive power apparatus. Power apparatus are invested, by the priority of loss sensitivities indices given for each bus.

  • PDF

A study on the system to evaluate the performance of novel ground apparatus (신개발 접지장치의 성능평가시스템에 관한 연구)

  • Park, Sang-Man;Jang, Sang-Ok;Park, Chang-Ho;Kang, Moon-Ho;Choi, Jong-Kee;Lee, Mun-Seok;Choi, Ha-Ok;Lee, Yong-Han;Hwang, Kwang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2666-2668
    • /
    • 2003
  • The most widely employed grounding apparatus in distribution systems is a driven rod. But this method has some difficulties to get a specified ground resistivity in cities or islands. Recently, the new ground apparatus are proposed. This paper describes the research which relates with the system to evaluate the performance of novel grounding apparatus.

  • PDF

A 3 Dimensional Characteristic Analysis of SLIM by the 2-D Finite Element Method (2차원 유한요소법에 의한 SLIM의 3차원적 특성 해석)

  • Cho, Yun-Hyun;Kim, Yong-Joo;Shin, Pan-Seok;Kang, Do-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.37-42
    • /
    • 1990
  • In order to obtain optimal design criteria and operating parameters, a Single-sided Linear Induction Motor (SLIM) is analysed by using a 2-D finite element method with magnetic and current vector potential. In the analysing procedures, the governing equation is derived from Maxwell's equation combined with the magnetic vector potential. As a forcing term, 3-phase voltage source is employed using the Kirchhoff's voltage law in order to look into effects of the unbalanced 3-phase currents and air gap flux density. Also, 2ndary eddy current distribution, longitudinal end and transverse edge effects are in turns visualized by flux lines in 3 different analysing planes as functions of frequency and input power.

  • PDF

A study on Shifting Load Pattern by Applied Time Adjust of Heating Apparatus (심야기기의 시간대 분산에 의한 부하평준화 방안)

  • Kim, C.S.;Rhee, C.H.;Jin, B.M.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.395-397
    • /
    • 2002
  • Recently, electric heating using midnight power has brought a rapid increase. Therefore, the increase of midnight power use has much influenced on midnight load pattern and share more than 20% of total midnight electricity consumption. Hence, the distortion of load by using midnight power apparatus is severe and made the usage pattern ineffective electricity usage pattern. This paper analyze the load pattern of midnight power apparatus and policies that can effectively build midnight load. In addition, it provides policies on shifting midnight power apparatus load.

  • PDF

On-Line Monitoring of Power Apparatus with Infrared Thermography (적외선 열화상을 이용한 수전설비 온라인 감시)

  • Lim, Young-Bae;Jeong, Seung-Cheon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.441-444
    • /
    • 2004
  • Each electrical apparatus radiates various infrared as the condition of surface and load current. Because heat distribution of the apparatus changes as the condition, it is able to analyze the condition of the apparatus by using the distribution. However, methods having been used to measure the heat distribution cannot compare normal condition with abnormal, and the apparatus has diagnosed by intuition. This paper deal with a program that is able to analyze changed temperature distribution. The program is to analyze temperatures on pixels in selected region of interest or position and is able momently and logically to analyze condition of the apparatus. The results are able to apply to a on-line monitoring system.

  • PDF