• Title/Summary/Keyword: Power and phase detecting

Search Result 99, Processing Time 0.025 seconds

Instantaneous Compensating Current Control of Active Power Filters with Phase Angle Detecting Method Under Unbalance Power System (불평형 전원 시스템하의 위상각 검출에 의한 능동전력필터의 순시보상 전류제어)

  • 정영국
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.752-755
    • /
    • 2000
  • This paper describes a new algorithm for active power filters which can be control source current symmetrically under unbalanced condition in power system. Positive sequency voltage is detected by symmetrical coordinate method and compensating reference current of active power filters is calculated using by accurate phase angle information of positive sequency voltage. The basic principle of the proposed method is described in detail and the conventional and proposed phase detecting methods are compared and discussed through the simulation results.

  • PDF

Open-Phase Condition Detecting System for Transformer Connected Power Line in Nuclear Power Plant (원자력발전소 변압기 연결 선로 결상 검출 시스템)

  • Ha, Che-Wung;Lee, Do-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.254-259
    • /
    • 2015
  • On January 30, 2012 an auxiliary component of Byron Unit 2 was tripped on bus under voltage. The cause of the event was the failure of the C-phase insulator track for the Unit 2 station auxiliary transformer(SAT) revenue metering transformer. In addition to this event, other events have occurred at other plants resulting in an open-phase condition.[1] Therefore, Nuclear Regulatory Commission(NRC) has requested that not only nuclear power plant(NPP) operating company but also its Design Certification(DC) applicant have to prepare open-phase detecting system in their operating plants and design document. In this paper, various open-phase conditions are simulated in NPP using Electromagnetic Transient Program(EMTP) and Atpdraw, and open-phase condition detecting system is proposed for Main Transformer(MT), Unit Auxiliary Transformer(UAT) and SAT connected power line in NPP.

Comparison of Harmonic Detecting Methods For Sing-Phase Multi Level Active Power Filters (단상 멀티레벨 능동전력필터를 위한 고조파 검지 기법 비교)

  • Kim, Yoon-Ho;Kim, Soo-Hong;Kim, Sung-Min;Seo, Kang-Moon
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.494-497
    • /
    • 2005
  • In this paper, harmonic detecting methods for the active power application are investigated. They are RDFT, Kalman Filter, Adaptive predictive filter, Instantaneous reactive power detecting method, Improved adaptive filter detecting method. The 5 harmonic detecting methods are simulated and their characteristics for the active filter application are compared using simulation results.

  • PDF

The Parallel Operation of Single Phase PWM Rectifier using IGBT (IGBT를 이용한 단산 PWM정류기 병렬운전)

  • 이현원;장성영;김연준;이광주;김남해
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.122-125
    • /
    • 1999
  • The AC-to-DC single-phase PWM rectifier for traction applications using high power semiconductor, IGCT is made and tested. Parallel operation of two PWM converter is adopted for increasing capacity of converters. For reducing harmonics, the harmonic content is eliminated by the phase shift between two converters switching phase. The output voltage control is achieved by interns calculation without detecting the input current. The part of PLL used for controlling power factor is simply implemented by software.

  • PDF

THE DETECTION OF INSTANTANEOUS DISTORTED CURRENT WITH THREE-DIMENSIONAL SPACE VECTOR

  • Mei, Tong;Jie, Tong;Jingpin, Jiangg
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.615-619
    • /
    • 1998
  • Active power filter is a kind of device used for compensating instantaneous reactive and harmonic current in three-phase circuits. An essential technology that determines the behavior of an active power filter is the method of detecting the distorted current. Using three-dimensional space vectors, this paper describes a simple method for detecting the distorted current without any coordinate transformation. The effectiveness of the novel method is verified by the theoretical analysis and simulation.

  • PDF

A Grid Current-Controlling Shunt Active Power Filter

  • Tumbelaka, Hanny H.;Borle, Lawrence J.;Nayar, Chemmangot V.;Lee, Seong-Ryong
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.365-376
    • /
    • 2009
  • In this paper, the implementation of a three-phase shunt active power filter is presented. The filter is essentially three independent single-phase current-controlled voltage source inverters (CC-VSI) with a common DC bus. The CC- VSI is operated to directly control the AC grid current to be sinusoidal and in phase with the grid voltage without detecting the load currents. The APF consists of a current control loop, which shapes the grid currents to be sinusoidal and a voltage control loop, which regulates the active power balance of the system. The experimental results indicate that the active filter is able to handle predominantly the harmonics, as well as the unbalance and reactive power, so that the grid currents are sinusoidal, in phase with the grid voltages and symmetrical.

A study on Reactor Parameter of Atmosphere Plasma Power Supply

  • Lee, Woo-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.291-292
    • /
    • 2011
  • This paper proposes an extraction method for reactor parameters in atmosphere plasma power supplies. This method is performed by detecting phase difference between inverter voltage and current, and extracting the reactance through reactive power. The validity of the proposed scheme is investigated through simulation results and experimental results.

  • PDF

A Study on Fault Detecting for Underground Power Transmission Lines using Optical Field Sensors (광응용 자계센서를 이용한 지중송전선 사고구간 검출에 관한 연구)

  • Lee, Kwang-Jung;Kim, Seok-Koo;Park, Hae-Soo;Kim, Yo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.91-93
    • /
    • 1994
  • Recently, for improving the power supply reliability and for rationslizing maintenance, new maintenance and monitoring systems are stornagly desired for use in the field of electric power transmission. In this paper, we describes the optical fault detecting method of underground power transmission lines using bareearth doped YIG Faraday sensors which are very light, small size and fast response. As regarding, we use the zero phase current detecting algorithm at insulated joints.

  • PDF

3-Phase Current Estimation of SRM Based on DC-Link Current (직류링크전류를 기반으로 한 SRM 3상전류 추정법)

  • Kim, Ju-Jin;Choi, Jae-Ho;Kim, Tae-Woong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.307-312
    • /
    • 2006
  • This paper proposes the SRM drive system, which accurately estimates the phase currents from the DC-link current to drive SRM instead of detecting the three-phase currents. In addition, the detecting circuit of DC-link current is also proposed to increase the resolution and decrease the off-set influence. Comparing with the general drive system based on the phase current, it is verified through the experiments that the proposed SRM drive system based on the DC-link current has the good performance in steady-state response of the speed control. Using the DC-link current, all of the 3-phase currents can be easily estimated for driving the SRM.

A New Gate Pulse Generating Method of 12-Pulse Phase Controlled Rectifier for HVDC (HVDC용 12-펄스 위상제어정류기의 새로운 게이트 펄스 발생 기법)

  • Ahn, Jong-Bo;Kim, Kook-Hun;Lee, Jong-Moo;Lee, Ki-Do
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.139-141
    • /
    • 2000
  • High voltage direct current(HVDC) transmission system uses the phase controlled rectifier triggered by means of IPC(individual phase control) or EPC(equidistant pulse control). Most HVDC system has adopted EPC method that can solve the harmonic instability problem of IPC method in weak power system. But EPC has inherent indirect synchronizing problem requiring the closed loop control. This paper presents the new gate pulse generating method for 12-pulse HVDC converter, which combines IPC with EPC. Simulation and test results are presented. The basic concept is that it generates the gating pulse for 12-pulse converter by synthesizing the internal phase reference using the frequency and phase information of a sin91e phase voltage. To ensure the reliability of the external phase input, Potential transformer that detects the phase voltage has redundancy. Using fault detecting algorithm the healthy input is always guaranteed. And the frequency compensation function was reinforced.

  • PDF