• Title/Summary/Keyword: Power System Control and Operation

Search Result 1,987, Processing Time 0.037 seconds

A Study on the Multi-carrier PWM Methods for Voltage Balancing of Flying Capacitor in the Flying Capacitor Multi-level Inverter (플라잉 커패시터 멀티레벨 인버터의 플라잉 커패시터 전압 균형을 위한 멀리 캐리어 PWM 기법에 대한 연구)

  • Jin, Bum-Seung;Kim, Tae-Jin;Kang, Dae-Wook;Hyun, Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.298-301
    • /
    • 2005
  • The flying capacitor voltage control of the flying capacitor multi-level inverter (FCMLI) is very important for safe operation. The voltage unbalancing of flying capacitors caused serious problems in safety and reliability of system. In the FCMLI, balancing problem of the flying capacitor has its applications limited. The voltage unbalance is occurred by the difference of each capacitors charging and discharging time applied to FCMLI. This paper investigates and analyzes multi-carrier PWM methods to solve capacitor voltage balancing problem. The Phase-Shift PWM (PSPWM) method that is commonly used, The Modified Carrier-Redistribution PWM (MCRPWM) method and The Saw-Tooth-Rotation PWM (STRPWM) method are discussed and compared with respect to switching state, balancing voltage of capacitors and output waveform. These three PWM methods are analyzed by using a flying capacitor three-level inverter and provided result through simulation. Finally, the harmonics about the output voltages of their methods are compared using the harmonic distortion factor (HDF).

  • PDF

Economical Gas Chamber for In-situ Gas Measurement and Analysis of Gas Response Characteristics according to Sensor Voltage (인시투 가스 측정이 가능한 경제적 가스 챔버 구현 및 센서 전압에 따른 가스 응답 특성 분석)

  • Choi, Yun-Suk;Lee, In Hwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.5
    • /
    • pp.1-8
    • /
    • 2019
  • Breath analysis using a portable device is better than the classical breath analysis system in terms of installation and operation. There is an increasing need to develop cost-effective equipment for testing gas sensors from the viewpoint of functionalities that can be applied applicable to portable devices. In the present study, an economical gas chamber for in-situ gas measurement is implemented with a single gas chamber without using expensive gas storage and control equipment; the gas response characteristics are analyzed using the above-described chamber. The main features of the implemented gas chamber are simple injection procedure, improved gas diffusion, easy measurement and cleaning, support for low-power mode measurement function for portable devices, and open source platform. Moreover, an analysis of gas response characteristics based on changes in sensor voltage show that the sensitivity and 90% response time are affected by the sensor voltage. Furthermore, the sensitivity graph has an inflection point in a specific range. The gas sensor applied in this study showed fast response speed and high sensitivity for sensor voltages of 3.0-3.5 V, regardless of the concentration of acetone gas, the target gas used in this study.

Experimental Analysis of Superconducting Fault Current Limiter Wound with Two Different HTS wires in Parallel

  • Kim, Ji-Tae;Jang, Jae-Young;Park, Dong-Keun;Chang, Ki-Sung;Kim, Young-Jae;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.2
    • /
    • pp.30-33
    • /
    • 2008
  • Several kinds of superconducting fault current limiters (SFCLs), which reduces huge fault current, have been developing by many research groups. The SFCL has no impedance during normal operation, so it dose not give any influence to electric power system. The resistive type SFCL reduces the fault current with the impedance generated in the superconducting part of the SFCL when the fault current exceeds the critical current of SFCL. In this paper, a new type resistive SFCL made of bifilar coil wound with two different high-Tc superconducting (HTS) wires in parallel. Although a bifilar coil has theoretically no inductance, the bifilar coil made in this paper could generate inductance at fault. The specifications of the used two wires were considerably different, thus current distribution between the two HTS wire was different at fault. When the fault current exceeded the critical current of one wire in the bifilar coil, the momentary sharp increase of impedance was detected. Base on the results, a new resistive type SFCL can generate not only resistance but also inductance, which can be used to control a fault current in the future.

Study on the Electromagnetic Sources and Victims of the High-Speed EMU (동력 분산형 고속전철의 전자파 Source 및 Victim에 관한 연구)

  • Gimm, Yoon-Myoung;Ju, Young-Jun;Koo, Eun-Hee;Koo, Bon-Chul;Yoo, Jae-Seong
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1209-1212
    • /
    • 2008
  • The high-speed EMU is assembled with distributed EMI sources. Therefore, it contains more electromagnetic sources nearby the distributed victims than the existing concentrated traction system. The electromagnetic sources and victims are identified in this research, and the methodology how to handle EMI/EMS/EMC of the high-speed EMU will be developed for safer operation. It includes measurement method, safety standards of control units and others, and performance evaluations of the firstly developed trial products for the EMU. Also influences by modern telecommunication equipments and effect of PLD(power line disturbance) are to be surveyed in this research.

  • PDF

Optimal Scheduling of Electric Vehicles Charging in low-Voltage Distribution Systems

  • Xu, Shaolun;Zhang, Liang;Yan, Zheng;Feng, Donghan;Wang, Gang;Zhao, Xiaobo
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.810-819
    • /
    • 2016
  • Uncoordinated charging of large-scale electric vehicles (EVs) will have a negative impact on the secure and economic operation of the power system, especially at the distribution level. Given that the charging load of EVs can be controlled to some extent, research on the optimal charging control of EVs has been extensively carried out. In this paper, two possible smart charging scenarios in China are studied: centralized optimal charging operated by an aggregator and decentralized optimal charging managed by individual users. Under the assumption that the aggregators and individual users only concern the economic benefits, new load peaks will arise under time of use (TOU) pricing which is extensively employed in China. To solve this problem, a simple incentive mechanism is proposed for centralized optimal charging while a rolling-update pricing scheme is devised for decentralized optimal charging. The original optimal charging models are modified to account for the developed schemes. Simulated tests corroborate the efficacy of optimal scheduling for charging EVs in various scenarios.

Development of Wireless Base Station Re4mote Monitoring System Using IoT Based on Cloud Server (클라우드 서버 기반 IoT를 이용한 무선기지국 원격 감시시스템 개발)

  • Lee, Yang-Weon;Kim, Chul-Won
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.491-494
    • /
    • 2018
  • Radio base stations, which are widely distributed across large areas, have many difficulties in managing them. Unmanned radio base stations in remote mountains are having a hard time accessing them in case of emergencies. Major telephone service providers only remotely control incoming and outgoing information and local small business partners responsible for maintaining actual facilities do not possess such technologies, so they are each checked during field visits. In this study, in order to monitor temperature, humidity, fire condition, and power operation at a wide range of radio base stations, real-time monitoring is carried out at the office of Klaus server through real-time monitoring.

  • PDF

Feasibility of combinational burnable poison pins for 24-month cycle PWR reload core

  • Dandi, Aiman;Lee, MinJae;Kim, Myung Hyun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.2
    • /
    • pp.238-247
    • /
    • 2020
  • The Burnable Poison (BP) is very important for all Light Water Reactors in order to hold-down the initial excess reactivity and to control power peaking. The use of BP is even more essential as the excess reactivity increases significantly with a longer operation cycle. In this paper a feasibility study was conducted in order to investigate the benefits of a new combinational BP concept designed for 24-month cycle PWR core. The reference designs in this study are based on the two Korean fuel assemblies; 17 × 17 Westinghouse (WH) design and 16 × 16 Combustion Engineering (CE) design. A modification was done on these two designs to extend their cycle length from 18 months into 24 months. DeCART2D-MASTER code system was used to perform assembly and core calculations for both designs. A preliminary test was conducted in order to choose the best BP suitable for 24-month as a representative for single BP concept. The comparison between the results of two concepts (combinational BP concept and single BP concept) showed that the combinational BP concept can replace the single BP concept with better performance on holding down the initial excess reactivity without violating the design limitations.

Operation and Control Strategy of a New Hybrid ESS-UPS system (수요관리와 비상발전기능을 갖는 새로운 하이브리드 ESS-UPS 시스템의 운영 및 제어전략)

  • Kim, Sang-jin;Kwon, Min-ho;Kim, Hyo-jun;Choi, Se-wan;Hwang, Dong-ok;Lee, Dong-ju;Paik, Seok-min
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.339-340
    • /
    • 2017
  • 본 논문은 에너지 저장시스템(ESS)과 무정전 전원장치(UPS)를 하나로 통합한 새로운 하이브리드 ESS-UPS 시스템을 제안한다. 제안하는 시스템은 ESS와 UPS를 하나로 통합함으로써 전력변환 시스템(PCS)의 가격을 줄이고 배터리의 이용률을 높일 수 있다. 또한 기존의 on-line UPS와는 달리 두 종류의 중요부하를 구성할 수 있어 PCS의 용량대비 비상발전 용량을 증대시키는 것이 가능하다. 본 논문에서는 제안하는 하이브리드 ESS-UPS 시스템의 운영 전략 및 급속 모드전환 알고리즘을 제안하며, 5kW급 축소 시작품을 통한 실험 결과로 타당성을 입증하였다.

  • PDF

Technical Trends of AI Military Staff to Support Decision-Making of Commanders (지휘관들의 의사결정지원을 위한 AI 군참모 기술동향)

  • Lee, C.E.;Son, J.H.;Park, H.S.;Lee, S.Y.;Park, S.J.;Lee, Y.T.
    • Electronics and Telecommunications Trends
    • /
    • v.36 no.1
    • /
    • pp.89-98
    • /
    • 2021
  • The Ministry of National Defense aims to create an environment in which transparent and reasonable defense policies can be implemented in real time by establishing the vision of smart defense innovation based on the Fourth Industrial Revolution and promoting innovation in technology-based defense operation systems. Artificial intelligence (AI) based defense technology is at the level of basic research worldwide, includes no domestic tasks, and involves classified military operation data and command control/decision information. Further, it is needed to secure independent technologies specialized for our military. In the army, military power continues to decline due to aging and declining population. In addition, it is expected that there will be more than 500,000 units should be managed simultaneously, to recognize the battle situation in real time on the future battlefields. Such a complex battlefield, command decisions will be limited by the experience and expertise of individual commanders. Accordingly, the study of AI core technologies supporting real-time combat command is actively pursued at home and abroad. It is necessary to strengthen future defense capabilities by identifying potential threats that commanders are likely to miss, improving the viability of the combat system, ensuring smart commanders always win conflicts and providing reasonable AI digital staff based on data science. This paper describes the recent research trends in AI military staff technology supporting commander decision-making, broken down into five key areas.

Simple Digital LCD Backlight Inverter using a Single-chip Microcontroller (단일칩 마이크로컨트롤러를 이용한 간단한 디지털 LCD 백라이트 인버터)

  • Jeong, Gang-Youl
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.461-468
    • /
    • 2010
  • This paper presents a simple digital LCD backlight inverter using a single-chip microcontroller. The proposed inverter reduces the ignition voltage and eliminates the current spikes and hence improves the ignition behavior of the cold cathode fluorescent lamp(CCFL). Thus it increases the CCFL's life span. This is achieved by implementing a digital dimming control algorithm, that contains the soft-starting algorithm, all on a single-chip microcontroller. The inverter utilizes the full-bridge resonant circuit topology. The design example along with a simple analysis for the inverter is shown, and the experimental results of the designed prototype results in close agreement with the theoretical analysis and explanation. The overall system's power efficiency is approximately 85%. Compared with conventional inverters, the ignition voltage is reduced by around 30% without any lamp current spike occurring during the dimming control operation.