• Title/Summary/Keyword: Power Source

Search Result 5,865, Processing Time 0.03 seconds

Unified MPPT Control Strategy for Z-Source Inverter Based Photovoltaic Power Conversion Systems

  • Thangaprakash, Sengodan
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.172-180
    • /
    • 2012
  • Z-source inverters (ZSI) are used to realize both DC voltage boost and DC-AC inversion in single stage with a reduced number of power switching devices. A traditional MPPT control algorithm provides a shoot-through interval which should be inserted in the switching waveforms of the inverter to output the maximum power to the Z-network. At this instant, the voltage across the Z-source capacitor is equal to the output voltage of a PV array at the maximum power point (MPP). The control of the Z-source capacitor voltage beyond the MPP voltage of a PV array is not facilitated in traditional MPPT algorithms. This paper presents a unified MPPT control algorithm to simultaneously achieve MPPT as well as Z-source capacitor voltage control. Development and implementation of the proposed algorithm and a comparison with traditional results are discussed. The effectiveness of the proposed unified MPPT control strategy is implemented in Matlab/Simulink software and verified by experimental results.

Impact of DPN on Deep Nano-technology Device Employing Dual Poly Gate (Nano-technology에 도입된 Dual Poly Gate에서의 DPN 공정 연구)

  • Kim, Chang-Jib;Roh, Yong-Han
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.4
    • /
    • pp.296-299
    • /
    • 2008
  • The effects of radio frequency (RF) source power for decoupled plasma nitridation (DPN) process on the electrical properties and Fowler-Nordheim (FN) stress immunity of the oxynitride gate dielectrics for deep nano-technology devices has been investigated. With increase of RF source power, the threshold voltage (Vth) of a NMOS transistor(TR) decreased and that of a PMOS transistor increased, indicating that the increase of nitrogen incorporation in the oxynitride layer due to higher RF source power induced more positive fixed charges. The improved off-current characteristics and wafer uniformity of PMOS Vth were observed with higher RF source power. FN stress immunity, however, has been degenerated with increasing RF source power, which was attributed to the increased trap sites in the oxynitride layer. With the experimental results, we could optimize the DPN process minimizing the power consumption of a device and satisfying the gate oxide reliability.

Voltage THD Mitigation of Power Distribution System using Z-Source Active Power Filter with a Fuel Cells Source (연료전지 전원을 갖는 Z-소스 능동전력필터에 의한 장거리 배전선로의 전압 THD 저감)

  • Jung, Young-Gook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2161-2166
    • /
    • 2008
  • This paper deals with a Z-source active power filter(Z-AFU) for mitigation voltage THD(total harmonic distortion) due to voltage harmonic propagation(amplification) in 6.6kv power distribution system. Bus voltage harmonic signal is detected by 60Hz butterworth BPF(band pass filter). As an ESS(energy storage system) of the proposed system, PEM fuel cells(Ballard NEXA, 1.2kw) is employed. Test results based on PSIM(power electronics simulation tool) validate the proposed approach.

Reactive Power Control Algorithm of Grid-Connected Inverter at the Point of Common Coupling With Compensation of Series and Parallel Impedances (직병렬 임피던스 보상을 통한 계통 연계 분산전원 인버터의 PCC 무효전력 제어 알고리즘)

  • Heo, Cheol-Young;Song, Seung-Ho;Kim, Yong-Rae
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.2
    • /
    • pp.92-99
    • /
    • 2022
  • Due to space and geographical constraints, the power source may be located outside the island area, resulting in the considerable length of transmission line. In these cases, when an active power is transmitted, unexpected reactive power is generated at a point of common coupling (PCC). Unlike the power transmitted from the power generation source, the reactive power adversely affects the system. This study proposes a new algorithm that controls reactive power at PCC. Causes of reactive power errors are separated into parallel and series components, which allows the algorithm to compensate the reactive current of the inverter output and control reactive power at the PCC through calculations from the impedance, voltage, and current. The proposed algorithm has economic advantages by controlling the reactive power with the inverter of the power source itself, and can flexibly control power against voltage and output variations. Through the simulation, the algorithm was verified by implementing a power source of 3 [kVA] capacity connected to the low voltage system and of 5 [MVA] capacity connected to the extra-high voltage system. Furthermore, a power source of 3 [kVA] capacity inverter is configured and connected to a mock grid, then confirmed through experiments.

Stability Control of Energy Storage Voltage Source Inverters in Isolated Power Systems

  • Hu, Jian;Fu, Lijun
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1844-1854
    • /
    • 2018
  • Isolated power systems (IPS) are often characterized by a weak grid due to small power grids. The grid side voltage is no longer equivalent to an ideal voltage source of an infinitely big power grid. The conversion control of new energy sources, parameter perturbations as well as the load itself can easily cause the system voltage to oscillate or to become unstable. To solve this problem, increasing the energy-storage power sources is usually used to improve the reliability of a system. In order to provide support for the voltage, the energy-storage power source inverter needs an method to control the voltage source. Therefore, this paper has proposed the active damping control of a voltage source inverter (VSI) based on virtual compensation. By simplifying the VSI double closed-loop control, two feedback compensation channels have been constructed to reduce the VSI output impedance without changing the characteristics of the voltage gain of a system. This improvement allows systems to operate stably in a larger range. A frequency-domain analysis, and simulation and experimental results demonstrate the feasibility and effectiveness of the proposed method.

Design and Implementation of High Power Source Measurement Unit (고 전력 Source Measurement Unit의 설계 및 제작)

  • Lee, Sang-Gu;Baek, Wang-Gi;Park, Jong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.860-863
    • /
    • 2003
  • In this paper high power SMU(Source Measurement Unit) having 50V/1.5A source/measure range has been designed and implemented. The SMU has two operation mode, voltage mode and current mode. The SMU can be used as variable voltage source, variable current source, voltage meter, or current meter. Combining two different unit, output power can be doubled as 100V/1.5A. The developed SMU tan be used many semiconductor testing system and electronic device inspecting system.

  • PDF

Research on Line Overload Emergency Control Strategy Based on the Source-Load Synergy Coefficient

  • Ma, Jing;Kang, Wenbo;Thorp, James S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1079-1088
    • /
    • 2018
  • A line overload emergency control strategy based on the source-load synergy coefficient is proposed in this paper. First, the definition of the source-load synergy coefficient is introduced. When line overload is detected, the source-load branch synergy coefficient and source-load distribution synergy coefficient are calculated according to the real-time operation mode of the system. Second, the generator tripping and load shedding control node set is determined according to the source-load branch synergy coefficient. And then, according to the line overload condition, the control quantity of each control node is determined using the Double Fitness Particle Swarm Optimization (DFPSO), with minimum system economic loss as the objective function. Thus load shedding for the overloaded line could be realized. On this basis, in order to guarantee continuous and reliable power supply, on the condition that no new line overload is caused, some of the untripped generators are selected according to the source-load distribution synergy coefficient to increase power output. Thus power supply could be restored to some of the shedded loads, and the economic loss caused by emergency control could be minimized. Simulation tests on the IEEE 10-machine 39-bus system verify the effectiveness and feasibility of the proposed strategy.

A Railway signal power supply system using the module type power supply (모듈형 파워 서플라이를 이용한 철도 신호용 전원장치)

  • Roh Sung-Chae;Lee Yoo-Kyung;Kim Soo-Hong
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.836-842
    • /
    • 2005
  • This paper presents a power supply of railway signal system using a Z-source inverter. The Z-source inverter overcomes the conceptual and theoretical barriers and limitations of the tradition voltage-source inverter and current-source inverter and provides novel power conversion concept. The Z-source inverter is a Buck-Boost inverter that has a wide range of obtainable voltage.

  • PDF

Failure analysis about deterioration of Source voltage in Power MOSFET (Power MOSFET에서 Source voltage 저하에 관한 Failure analysis)

  • 정재성;김종문;이재혁;하종신;박상득
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.1109-1112
    • /
    • 2003
  • 본 연구는 switching mode 의 Power NMOSFET failure mode 에 관하여 분석하고 원인을 규명하였다. 분석된 power NMOSFET은 30V급이며, vender A의 상용화 제품이다. 발생한 failure mode는 power switch 회로에서 특정 ID 를 detect 하지 못하는 mode 였다. 측정결과 source voltage 가 저하되었으며, power NMOSFET DC 동작특성 분석 결과 Vgs 변화에 따라 Id 가 저하되었다. Fail 된 power MOSFET 특성값 reference는 동일 LOT의 양품을 선정하였다. De-cap후 Inversion 과 Accumulation mode 별로 Photoemission spectrum analyzer(PSA) 분석 방법을 적용하였다. 결과 accumulation mode 에서 intensity가 감소하였으며, forward diode mode에서 국소적으로 변화하는 영역이 검출되었다. SEM 분석결과 gate metal 과 source metal 의 micro-contact 이 이루어져 있었다. 이 경우 gate metal 과 source metal 사이 close loop 를 형성하여 gate charge량을 변화시켜 power NMOSFET의 출력을 저하하는 failure mode가 발생됨을 분석할 수 있었다.

  • PDF

3-Phase Hybrid Series Active Power Filter with Instantaneous Voltage Fluctuations Compensation (순간전압변동 보상 기능을 갖는 3상 하이브리드형 직렬 능동전력필터)

  • 한석우;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.6
    • /
    • pp.544-551
    • /
    • 2000
  • In this paper, 3-phase hybrid series active power filter for compensate current harmonics, voltage drop and unbalanced voltage in the network presented. The proposed system is implemented with a space vector modulation voltage source inverter and a high pass filter connected in parallel to the power system. Here the load is six-pulses thyristor rectifier. The phase angle detected in order to generation reference voltage at load terminal is synchronized with the positive sequence component of the unbalanced source by using symmetrical component transformation. The proposed system has an function harmonic isolation between source and load, voltage regulation, and unbalance compensation. Therefore, what the power system is improved quality, the source current is maintained as a nearly sinusoidal waveform and the load voltage is regulated with a rated voltage regardless of the source variation condition. To verify the validity of the proposed compensating system, the computer simulation and experiment are carried out.

  • PDF