• 제목/요약/키워드: Power Response

검색결과 3,875건 처리시간 0.031초

진동대 실험을 통한 전단벽 구조물의 층응답 특성 평가 (In-structure Response Evaluation of Shear Wall Structure via Shaking Table Tests)

  • 정재욱;하정곤;함대기;김민규
    • 한국지진공학회논문집
    • /
    • 제25권3호
    • /
    • pp.129-135
    • /
    • 2021
  • After the manual shutdown of the Wolseong nuclear power plant due to an earthquake in Gyeongju in 2016, anxiety about the earthquake safety of nuclear power plants has become a major social issue. The shear wall structure used as a major structural element in nuclear power plants is widely used as a major structural member because of its high resistance to horizontal loads such as earthquakes. However, due to the complexity of the structure, it is challenging to predict the dynamic characteristics of the structure. In this study, a three-story shear wall structure is fabricated, and the in-structure response characteristics of the shear wall structure are evaluated through shaking table tests. The test is performed using the Gyeongju earthquake that occurred in 2016, and the response characteristics due to the domestic earthquake are evaluated.

캐비닛내부응답스펙트럼 산정을 위한 리츠방법의 정식화 및 단순예제를 통한 검증 (Formulation and Verification on Ritz Method for In-Cabinet Response Spectrum)

  • 김기현;홍기증;조성국;박웅기
    • 한국지진공학회논문집
    • /
    • 제23권5호
    • /
    • pp.279-288
    • /
    • 2019
  • Safety-related cabinets and their electrical parts, such as relays and switches in nuclear power plants, should maintain continuous functioning, as well as structural safety according to the nuclear regulatory guidelines. Generally, an electrical part is qualified if its functioning is maintained without abnormality during excitement by motion compatible with the test response spectrum, which is larger than its in-cabinet response spectrum (ICRS). ICRS can be determined by shake-table test or dynamic analysis. Since existing cabinets in use can hardly be stopped and moved, dynamic analysis is preferred over shake-table test in determining ICRS. The simple method, suggested by the Electric Power Research Institute (EPRI) to determine ICRS, yields conservative or non-conservative results from time to time. In order to determine that the ICRS is better than EPRI method in a simple way, Ritz method considering global and local plate behaviors was suggested by Gupta et al. In this paper, the Ritz method is modified in order to consider the rocking and frame behaviors simultaneously, and it is applied to a simple numerical example for verification. ICRS is determined by Ritz method and compared with the results by finite element method (FEM). Based on this numerical example, recommendations for using Ritz method are suggested.

디젤기관의 분사밸브를 위한 고속 솔레노이드의 성능에 관한 연구 (A Study of Performance Test of High Speed Solenoid for Fuel Injector in Diesel Engine)

  • 조규학;라진홍;안수길
    • 동력기계공학회지
    • /
    • 제5권3호
    • /
    • pp.11-16
    • /
    • 2001
  • In the DI diesel engine of passenger cars, common rail injection system have been used to improve the engine performance and reduce the exhaust emission by controlling injection timing, injection pattern, and injection duration. In case that common rail injection system is applied to high speed DI diesel engine, it is necessary to have high response and good repetition characteristics. These characteristics of injector depend on the characteristics of solenoid. Thus, to apply the common rail injection system in the high speed diesel engine, we had designed and made a multi-pole solenoid, and carried out repetition, response test to compare the multi-pole solenoid with the gasoline Injector solenoid. The result shows that repetition and response characteristics of multi-pole solenoid have better characteristics than the gasoline injector solenoid.

  • PDF

반응표면법을 이용한 연료전지 분리판의 최적설계 (Optimization of the Plate in a Fuel Cell Using the Response Surface Method)

  • 한오현;박정선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.510-515
    • /
    • 2004
  • A proton exchange membrane fuel cells(PEMFC) operate at low temperature, allowing for faster startups and immediate response to change in the demand for power, and also deliver high power density. To maximize economical efficiency in PEMPC, it is necessary to the optimization. Response surface method(RSM) has non-gradient and fast convergency characteristics. Sampling points are extracted by design of experiments using Central Composite Method. In this paper, it is shown that the optimization is required for the design study of the PEMFC.

  • PDF

주파수 응답함수의 감도를 이용한 모델개선법 (Model Updating Using Sensitivity of Frequency Response Function)

  • 김광근;김영찬;양보석;김동조
    • 동력기계공학회지
    • /
    • 제4권2호
    • /
    • pp.71-76
    • /
    • 2000
  • It is well known that finite element analysis often has the inaccuracy when they are in conflict with test results. Model updating is concerned with the correction of analytical model by processing records of response from test results. This paper introduce a model updating technique using the frequency response function data. The measurement data is able to be used directly in the FRF sensitivity method because it is not necessary to identify. When a damping model is updated, it is necessary for the sensitivity matrix to be divided Into the complex part and real part. As an applying model, a cantilever and a rotor system are used. Specially the machined clearance($C_p$) of the journal bearing is updated.

  • PDF

Competition and Coalition of the Participants with Demand Response in Electricity Market

  • Lee, Kwang-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2157-2165
    • /
    • 2017
  • This study deals with the design of the mechanism in which demand response (DR) resources are traded in the power generation market. In general, a DR aggregator (DRA), which extends DR resources and provides technical support, is central to this mechanism. In this study, power users, called DR customer (DRC), participate in load reduction and are also modeled to participate directly in DR-related bidding. The DRA provides incentives to the DRC, indirectly impacting the market, and the DRC use the bid parameters strategically. We present the conditions for finding Nash Equilibrium (NE) in game problems of various participants including market operators, and analyze the characteristics of DRA and DRC related models. It also analyzes the impact of the participants on the market according to various types of competition and coalitions between DRA and DRC.

축대칭 하중을 받는 원통형 셸의 동적응답 해석 (Dynamic Response Analysis of Cylindrical Shell with Axisymmetric Loading)

  • 최명수;여동준
    • 동력기계공학회지
    • /
    • 제17권6호
    • /
    • pp.33-39
    • /
    • 2013
  • It is very important to analyze the dynamic responses of the shell structures from the viewpoint of the design of shell structures with a variety of axisymmetric loadings. In this paper, the computational algorithm for the dynamic response analysis of an cylindrical shell with axisymmetric loading is formulated by the transfer mass coefficient method based on the transfer of mass coefficient. After the computational programs for obtaining the dynamic responses of cylindrical shells with axisymmetric loading are made by the transfer mass coefficient method and the finite element method, the computational results by both methods are compared. From the computational results, we can confirm that the transfer mass coefficient method has the effectiveness in the dynamic response analyses of cylindrical shells with a variety of axisymmetric loadings.

Dual 전압공급에 의한 PM 스텝모우터의 다 스텝 응답개선 (An Improvement of Multistep Response of PM Step Motor Using Dual Voltage Power Supply)

  • Kim, Do-Hyun
    • 대한전자공학회논문지
    • /
    • 제25권3호
    • /
    • pp.269-275
    • /
    • 1988
  • In this paper, a high efficiency motor drive system which improves the multi-step response of PM step motors by reducing the transition time of the motor drive current, is studied by designing a dual-voltage drive circuit. The designed drive circuit eventually prevents the motor from decreasing drive torque while the stepping rate is increased. The method of designing a dual-voltage drive circuit with the motor specifications is suggested in order to improve the response of step rate and drive efficiency. Also, despite improving the power efficiency on motor driving, the response characterstics suggested by the motor manufacture's specifications are satisfied without any special deficiency.

  • PDF

MR Brake를 이용한 공압 머니퓰레이터의 과도응답특성의 향상 (Improvement of Transient Response Characteristics of Pneumatic Manipulator using MR Brake)

  • 안경관;송주영
    • 유공압시스템학회논문집
    • /
    • 제1권1호
    • /
    • pp.17-22
    • /
    • 2004
  • The goal of this paper is to improve the position control performance of pneumatic rotary actuator with variable brake using Magneto-Rheological Fluid. The air compressibility and the lack of damping of the pneumatic actuator bring the dynamic delay of the pressure response and cause the oscillatory motion. In this study, a variable rotary brake comprising Magneto-Rheological Fluid is equipped to the joint of a pneumatic manipulator. Experiments of step response have proved that the transient response of the manipulator could be improved compared with that of the conventional control algorithm by using a phase plane switching control algorithm.

  • PDF

Rapid Dynamic Response Flyback AC-DC Converter Design

  • Chang, Changyuan;Wu, Menglin;He, Luyang;Zhao, Dadi
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1627-1633
    • /
    • 2018
  • A constant voltage AC-DC converter based on digital assistant technology is proposed in this paper, which has rapid dynamic response capability. The converter operates in the PFM (Pulse Frequency Modulation) mode. According to the load state, the compensation current produced by the digital compensation module was injected into the CS pin to adjust the switching pulse width dynamically and improve the dynamic response. The control chip is implemented based on NEC $1{\mu}m$ 5V/40V HVCMOS process. A 5V/1.2A prototype has been built to verify the proposed control method. When the load jumps from idle to heavy, the undershoot time is only 7.4ms.