• Title/Summary/Keyword: Power Quality Disturbance

Search Result 87, Processing Time 0.021 seconds

Power Quality Early Warning Based on Anomaly Detection

  • Gu, Wei;Bai, Jingjing;Yuan, Xiaodong;Zhang, Shuai;Wang, Yuankai
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1171-1181
    • /
    • 2014
  • Different power quality (PQ) disturbance sources can have major impacts on the power supply grid. This study proposes, for the first time, an early warning approach to identifying PQ problems and providing early warning prompts based on the monitored data of PQ disturbance sources. To establish a steady-state power quality early warning index system, the characteristics of PQ disturbance sources are analyzed and summed up. The higher order statistics anomaly detection (HOSAD) algorithm, based on skewness and kurtosis, and hierarchical power quality early warning flow, were then used to mine limit-exceeding and abnormal data and analyze their severity. Cases studies show that the proposed approach is effective and feasible, and that it is possible to provide timely power quality early warnings for limit-exceeding and abnormal data.

A Study of the Compression for the Power Quality Disturbance Signal by using the Phase Estimation of Stationary Signal (정상신호의 위상 추정을 이용한 전력 품질 왜곡 신호의 압축에 관한 연구)

  • Chung, Young-Sik;Park, Chan-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.341-343
    • /
    • 2005
  • This paper introduces a compression algorithm for power quality disturbance signal via the discrete wavelet transform, DWT. Algorithm to estimate a time delay from the power quality disturbance signal is proposed. Pseudo-stationary signal is constructed from the estimated time delay. A difference signal or nonstationary signal is obtained by removing a pseudo-stationary signal from a disturbance signal. DWT is applied to a difference signal. The threshold is applied to reduce a number of coefficients. Simulation results show the resonable compression ratio while keep low signal distortion.

  • PDF

A Study on Filcker Evaluation Considering Power Quality Disturbance of Power System (전력계통의 전력품질 외란을 고려한 플리커 평가에 관한 연구)

  • Jung, Seung-Bock;Kim, Jae-Chul;Lee, Bong-Yi;Cho, Hyun-Kyung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.391-393
    • /
    • 2005
  • This paper studies flicker evaluation considering power quality disturbance. A flicker problem with light device irritates human's eyes. Also, the flicker problem has an influence on adverse effect such as rolling device and rotating device. However, a study of flicker evaluation is not complete. A flicker is measured and evaluated at monitoring point. But we consider power quality disturbances such as voltage sag and transient that cause fault and inverter/breaker switching. Power quality disturbances affects flicker evaluation. A flicker evaluation index increases. Therefore, we consider power quality disturbances. We detect voltage sag and transient using wavelet and evaluate flicker without flicker index including power quality disturbances.

  • PDF

Power Quality Improvement for Grid Connected Inverters under Distorted and Unbalanced Grids

  • Kim, Hyun-Sou;Kim, Jung-Su;Kim, Kyeong-Hwa
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1578-1586
    • /
    • 2016
  • A power quality improvement scheme for grid connected inverters, even in the presence of the disturbances in grid voltages due to harmonic distortions and three-phase imbalance, is presented for distributed generation (DG) power systems. The control objective is to force the inverter currents to follow their references with robustness even under external disturbances in grid voltages. The proposed scheme is realized by a disturbance observer (DOB) based current control scheme. Since the uncertainty in a system can be effectively canceled out using an estimated disturbance by the DOB, the resultant system behaves like a closed-loop system consisting of a disturbance-free nominal model. For experimental verification, a 2 kVA laboratory prototype of a grid connected inverter has been built using a digital signal processor (DSP) TMS320F28335. Through comparative simulations and experimental results under grid disturbances such as harmonic distortion and imbalance, the effectiveness of the proposed DOB based current control scheme is demonstrated.

Classification of Power Quality Disturbances Using Feature Vector Combination and Neural Networks (특징벡터 결합과 신경회로망을 이용한 전력외란 식별)

  • Nam, Sang-Won
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.671-674
    • /
    • 1997
  • The objective of this paper is to present a new feature-vector extraction method for the automatic detection and classification of power quality(PQ) disturbances, where FIT, DWT(Discrete Wavelet Transform), and Fisher's criterion are utilized to extract an appropriate feature vector. In particular, the proposed classifier consists of three parts: i.e., (i) automatic detection of PQ disturbances, where the wavelet transform and signal power estimation method are utilized to detect each disturbance, (ii) feature vector extraction from the detected disturbance, and (iii) automatic classification, where Multi-Layer Perceptron(MLP) is used to classify each disturbance from the corresponding extracted feature vector. To demonstrate the performance and applicability of the proposed classification algorithm, some test results obtained by analyzing 10-class power quality disturbances are also provided.

  • PDF

A Study on Filcker Evaluation Considering Power Quality Disturbance of Power System (전력계통의 전력품질 외란을 고려한 플리커 평가에 관한 연구)

  • Jung, Seung-Bock;Kim, Jae-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.376-379
    • /
    • 2006
  • This paper studies flicker evaluation considering power quality disturbance. A flicker problem with light device irritates human's eyes. Also, the flicker problem has an influence on adverse effect such as rolling device and rotating device. However, a study of flicker evaluation is not complete. A flicker is measured and evaluated at monitoring point. But we consider power qualify disturbances such as voltage sag and transient that cause fault and inverter/breaker switching. Power quality disturbances affects flicker evaluation. A flicker evaluation index increases. Therefore, we consider power quality disturbances. We detect voltage sag and transient using wavelet and evaluate flicker without flicker index including power quality disturbances.

  • PDF

Recognition and Classification of Power Quality Disturbances on the basis of Pattern Linguistic Values

  • Liu, XiaoSheng;Liu, Bo;Xu, DianGuo
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.309-319
    • /
    • 2016
  • This paper presents a new recognition and classification method for power quality (PQ) disturbances on the basis of pattern linguistic values. This method solves the difficulty of recognizing disturbances rapidly and accurately by using fuzzy logic. This method uses classification disturbance patterns to define the linguistic values of fuzzy input variables and used the input variables of corresponding disturbance pattern to set membership functions. This method also sets the fuzzy rules by analyzing the distribution regularities of the input variable values. One characteristic of this method is that the linguistic values of fuzzy input variables and the setting of membership functions are not only related to the input variables but also to the character of classification disturbance and the classification results. Furthermore, the number of fuzzy rules is equal to the number of disturbance patterns. By using this method for disturbance classification, the membership function and design of fuzzy rules are directly related to the objective of classification, thus effectively reducing the complexity of the design process and yielding accurate classification results. The classification results of the simulation and measured data verify the feasibility and effectiveness of this method.

Power Quality Disturbance Generator with Phase Jump for the Test of Microgrid (마이크로그리드 시험을 위한 전압 위상 변동 기능을 가지는 전력품질외란 발생기)

  • Jung, Jae-Hun;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.3
    • /
    • pp.104-110
    • /
    • 2015
  • This paper describes a power quality disturbance generator for the test of a microgrid. The generator provides phase-angle jump as well as voltage sag with simple structure. The main components of the generator are SCR thyristors and transformers, therefore, high reliability and high efficiency can be obtained without switching losses. The operating principle of the proposed scheme is described and the voltage and current characteristics in case of voltage sag with phase-angle jump is analyzed. The usefulness of the proposed topology is verified through simulations and experimental results.

Power Quality Data Compression using Wavelet Transform (웨이브렛 변환을 이용한 전력품질 데이터 압축에 관한 연구)

  • Chung Young-Sik
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.12
    • /
    • pp.561-566
    • /
    • 2005
  • This paper introduces a compression technique for power qualify disturbance signal via discrete wavelet transform(DWT). The proposed approach is based on a previous estimation of the stationary component of power quality disturbance signal, so that it could be subtracted from the original signal in order to reduce a dynamic range of signal and generate transient events signal, which is subsequently applied to the compression technique. The compression techniques is performed through the difference signal decomposition, thresholding of wavelet coefficients, and signal reconstruction. It presents the relation between compression efficiency and threshold. It shouts that the wavelet transform leads to a power quality data compression approach with high compression efficiency, small compression error and good de-nosing effect.