• Title/Summary/Keyword: Power Qualify

Search Result 82, Processing Time 0.027 seconds

Electrical Properties of Multilayer Piezoelectric Transformer using PMN-PZN-PZT Ceramics (PMN-PZN-PZT 세라믹스를 이용한 적층형 압전변압기의 전기적 특성)

  • Lee, Chang-Bae;Yoo, Ju-Hyun;Paik, Dong-Soo;Kang, Jin-Kyu;Cho, Hong-Hee;Lee, Sung-Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.7
    • /
    • pp.655-661
    • /
    • 2006
  • Dielectric and piezoelectric properties of PMN-PZT ceramics with a high mechanical quality factor$(Q_m)$ and a low temperature sintering temperature were investigated as a function of PZN substitution in order to develop multilayer piezoelectric transformer for AC-DC converter. Multilayer piezoelectric transformers were subsequently manufactured using the PMN-PZN-PZT ceramic offering the optimal behavior and then the electrical performance were invetigated. At the sintering temperature of $940^{\circ}C$, density, electromechanical coupling factor$(k_p)$, mechanical qualify factor$(Q_m)$ and dielectric constant$(\varepsilon_r)$ of 8 mol% PZN substituted specimen were $7.73g/cm^3$, 0.524, 1573 and 1455, respectively. The PZN substitution caused a increase in the dielectric constant and the electromechnical coupling factor. The voltage step-up ratio of multilayer piezoelectric transformer showed the maximum value at near the resonant frequency of 76.55 kHz and increased according to the increase of load resistance. The multilayer piezoelectric transformer with the output impedance coincided with the load resistance showed the temperature increase of less than $20^{\circ}C$ at the output power of 10 W. Based on the results, the manufactured multilayer transformer using the low temperature sintered PMN-PZN-PZT ceramics can be stably driven for both step-up and down transformers.

Study on Development of Medical Software Evaluation Criteria (의료용 소프트웨어의 평가기준 개발에 관한 연구)

  • Yang, Hae-Sool;Pyon, Ung-Bum;Lee, Jeong-Rim;Ryu, Gyu-Ha
    • The KIPS Transactions:PartD
    • /
    • v.10D no.5
    • /
    • pp.781-792
    • /
    • 2003
  • We medical software is becoming important means to secure competitive power of medical service by explosive increase of medical device based on software, and the quality of medical service is affected to quality of medical software as well as medical devices. But domestic related study and development is not sufficient for quality of medical software, and a falling-off in medical software quality can induce a falling-off in quality of medical service. Therefore, it is necessary to raise qualitative level of medical service by progress and quality improvement of medical devices. Therefore, in this paper, we developed test module and qualify inspection table which can test medical software and produce result based on ISO/1EC 12119.

Measurement and Analysis of Image Brightness in Fiber-optic Imageguide for Ultrathin Endoscope (미세내시경용 광섬유 영상가이드의 영상광도 측정 및 분석)

  • 이봉수
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.263-268
    • /
    • 2002
  • The image quality of imageguide depends on the structure, material, length of microfibers and the phenomena such as cross-talk and leaky ray between adjacent fibers. These Parameters should be considered as important factors in the image transmission qualify of fibers. However it is considered to be very difficult to assess all the parameters in a consistent way Therefore. two image characteristics, image resolution and image brightness are measured and analyzed to determine the image quality of imageguide. But the exact methods to measure two image characteristics of imageguide are not reported. In this study, the image brightness of imageguide for ultrathin endoscope is determined by measuring of the numerical aperture. the packing fraction and the attenuated power ratio of imageguide. Especially it is possible to obtain more exact results from measuring the numerical aperture of whole image guide than those from theoretical calculation of the single microfiber in an image guide. The image brightness of the image guide which has $3.1\mu m$ microfibers is about 37% less than that with $4.1\mu m$ microfibers.

Fast Frame Selection Method for Multi-Reference and Variable Block Motion Estimation (다중참조 및 가변블록 움직임 추정을 위한 고속 참조영상 선택 방법)

  • Kim, Sung-Dae;SunWoo, Myung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.6
    • /
    • pp.1-8
    • /
    • 2008
  • This paper introduces three efficient frame selection schemes to reduce the computation complexity for the multi-reference and variable block size Motion Estimation (ME). The proposed RSP (Reference Selection Pass) scheme can minimize the overhead of frame selection. The MFS (Modified Frame Selection) scheme can reduce the number of search points about 18% compared with existing schemes considering the motion of image during the reference frame selection process. In addition, the TPRFS (Two Pass Reference frame Selection) scheme can minimize the frame selection operation for the variable block size ME in H.264/AVC using the character of selected reference frame according to the block size. The simulation results show the proposed schemes can save up to 50% of the ME computation without degradation of image Qualify. Because the proposed schemes can be separated from the block matching process, they can be used with any existing single reference fast search algorithms.

IRRADIATION DEVICE FOR IRRADIATION TESTING OF COATED PARTICLE FUEL AT HANARO

  • Kim, Bong Goo;Park, Sung Jae;Hong, Sung Taek;Lee, Byung Chul;Jeong, Kyung-Chai;Kim, Yeon-Ku;Kim, Woong Ki;Lee, Young Woo;Cho, Moon Sung;Kim, Yong Wan
    • Nuclear Engineering and Technology
    • /
    • v.45 no.7
    • /
    • pp.941-950
    • /
    • 2013
  • The Korean Nuclear-Hydrogen Technology Development (NHTD) Plan will be performing irradiation testing of coated particle fuel at HANARO to support the development of VHTR in Korea. This testing will be carried out to demonstrate and qualify TRISO-coated particle fuel for use in VHTR. The testing will be irradiated in an inert gas atmosphere without on-line temperature monitoring and control combined with on-line fission product monitoring of the sweep gas. The irradiation device contains two test rods, one has nine fuel compacts and the other five compacts and eight graphite specimens. Each compact contains about 260 TRISO-coated particles. The irradiation device is being loaded and irradiated into the OR5 hole of the in HANARO core from August 2013. The device will be operated for about 150 effective full-power days at a peak temperature of about $1030^{\circ}C$ in BOC (Beginning of Cycle) during irradiation testing. After a peak burn-up of about 4 atomic percentage and a peak fast neutron fluence of about $1.7{\times}10^{21}\;n/cm^2$, PIE (Post-Irradiation Examination) of the irradiated coated particle fuel will be performed at IMEF (Irradiated Material Examination Facility). This paper reviews the design of test rod and irradiation device for coated particle fuel, and discusses the technical results for irradiation testing at HANARO.

Design and Implementation of An Authentication System for Residential Permit Parking Using Wireless Sensor Networks (무선 센서 네트워크를 이용한 거주자우선주차 인증시스템의 설계 및 구현)

  • Park, Jun-Sik;Kwon, Chun-Ja;Kim, Hyun-Chun;Kim, Brian
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.5
    • /
    • pp.1037-1045
    • /
    • 2007
  • An efficient management system for parking lots and traffic monitoring in a metropolitan city is a very important issue, which is tightly closed to qualify of life. While a residential permit parking program has been contributing to resolve the lack of parking places, there has been no autonomous authentication system due to no apparent entrance gate and smallness of each parking zone. In this paper, we propose and implement an authentication system for residential permit parking lot using wireless sensor networks, which is cost-effective and even no need for additional managing person. Through the experimental evaluation, we analyzed relationship between the life time of sensor nodes and the various values of sleep periods to minimize power consumption of the nodes, and also showed that the difference of luminance sensed by each sensor node is at least 45 or bigger between when the parking place is occupied or not, resultingly it can be used to decide whether a parking place is occupied or not by simply detecting the change of luminance sensed.

A study on the manufacturing of metal/plastic multi-components using the DSI molding (DSI 성형을 이용한 금속/플라스틱 복합 부품 제조에 관한 연구)

  • Ha, Seok-Jae;Cha, Baeg-Soon;Ko, Young-Bae
    • Design & Manufacturing
    • /
    • v.14 no.4
    • /
    • pp.71-77
    • /
    • 2020
  • Various manufacturing technologies, including over-molding and insert-injection molding, are used to produce hybrid plastics and metals. However, there are disadvantages to these technologies, as they require several steps in manufacturing and are limited to what can be reasonably achieved within the complexities of part geometry. This study aims to determine a practical approach for producing metal/plastic hybrid components by combining plastic injection molding and metal die casting to create a new hybrid metal/plastic molding process. The integrated metal/plastic hybrid injection molding process developed in this study uses the proven method of multi-component technology as a basis to combine plastic injection molding with metal die casting into one integrated process. In this study, the electrical conductivity and ampacity were verified to qualify the new process for the production of parts used in electronic devices. The electrical conductivity was measured, contacting both sides of the test sample with constant pressure, and the resistivity was measured using a micro ohmmeter. Also, the specific conductivity was subsequently calculated from the resistivity and contact surface of the conductor path. The ampacity defines the maximum amount of current a conductive path can carry before sustaining immediate or progressive deterioration. The manufactured hybrid multi-components were loaded with increasing currents, while the temperature was recorded with an infrared camera. To compare the measured infrared images, an electro-thermal simulation was conducted using commercial CAE software to predict the maximum temperature of the power loaded parts. Overall, during the injection molding process, it was demonstrated that multifunctional parts can be produced for electric and electronic applications.

Analyses of the Double-Layered Repository Concepts for Spent Nuclear Fuels (사용후핵연료 심지층 처분장 복층개념 분석)

  • Lee, Jongyoul;Kim, Hyeona;Lee, Minsoo;Choi, Heui-Joo;Kim, Kyungsu
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.2
    • /
    • pp.151-159
    • /
    • 2017
  • A deep geological disposal at a depth of 500 m in stable host rock is considered to be the safest method with current technologies for disposal of spent fuels classified as high-level radioactive waste. The most important requirement is that the temperature of the bentonite buffer, which is a component of the engineered barrier, should not exceed $100^{\circ}C$. In Korea, the amount of spent fuel generated by nuclear power generation, which accounts for about 30% of the total electricity, is continuously increasing and accumulating. Accordingly, the area required to dispose of it is also increasing. In this study, various duplex disposal concepts were derived for the purpose of improving the disposal efficiency by reducing the disposal area. Based on these concepts, thermal analyses were carried out to confirm whether the critical disposal system requirements were met, and the thermal stability of the disposal system was evaluated by analyzing the results. The results showed that upward 75 m or downward 75 m apart from the reference disposal system location of 500 m depth would qualify for the double layered disposal concept. The results of this study can be applied to the establishment of spent fuel management policy and the design of practical commercial disposal system. Detailed analyses with data of a real disposal site are necessary.

The Present State of an Air Pollutants Inflow into Gyeongju and Effects on Stone Cultural Properties (경주권역으로의 대기오염물질 유입현황과 석조문화재에 미치는 영향)

  • Jung, Jong-Hyeon;Shon, Byung-Hyun;Kim, Hyun-Gyu;Choi, Won-Joon;Nam, Chul-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.5 s.86
    • /
    • pp.349-359
    • /
    • 2005
  • In this study, we focused on the geographical and the meterological conditions, the atmospheric examination, the soil contents and compositions in order to establish cultural properties conservation plan in Gyeongju and its surroundings. Also, the transport route with environmental contaminants in Ulsan and Pohang was examined. The results could be summarized as follows ; Air pollutant and environmental contaminant was transported by two types of winds. One is induced by local winds, the other is induced by synoptic winds. Air contaminant transported from coastal regions to inland regions were associated with wind velocity. Gyeongju had good atmospheric conditions, i.e. $SO_2\;0.009{\sim}0.011ppm,\;CO\;0.6{\sim}0.8ppm,\;NO_2\;0.015{\sim}0.020ppm,\;O_3\;0.017{\sim}0.032ppm,\;PM_{10}\;46{\sim}62{\mu}g/m^3\;and\;Pb\;0.034{\sim}0.060{\mu}g/m^3$, which was below environmental air qualify standards and was little lower than those of Pohang and Ulsan. However, Ulsan and Pohang city are located on south-east coast and have many industrial facilities. Hence, air pollution problems become serious issues in Ulsan, Pohang, Busan, Daegu and other cities due to the emission of air pollutants from the various industrial facilities, incinerator and power plants, etc. The soil of Gyeongju had heavy metals conditions, i.e. $Cd\;0.01{\sim}0.08mg/kg,\;Cu\;N.D{\sim}2.39mg/kg,\;As\;N.D{\sim}0.07mg/kg,\;Hg\;N.D{\sim}0.15mg/kg,\;Pb\;0.49{\sim}1.39mg/kg,\;Cr^{+6}\;0.02{\sim}0.42mg/kg,\;Fe\;0.74{\sim}1.55mg/kg,\;Mn\;0.11{\sim}0.49mg/kg\;and\;Zn\;1.11{\sim}3.56mg/kg$. However, pH value of soil had range of $4.12{\sim}7.45$. The results showed that high pH concentration of soil could occur due to air pollution diffusion and environmental contaminant transport at Ulsan and Pohang city.

Characteristics Testing of the ECT Bobbin Probe for Steam Generator Tube Inspection of Nuclear Power Plant (원전 증기발생기 전열관 와전류검사 보빈탐촉자의 특성 시험)

  • Nam, Min-Woo;Lee, Hee-Jong;Cho, Chan-Hee;Yoo, Hyun-Joo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.386-395
    • /
    • 2010
  • The steam generator management program(SGMP) has recently defined the procedures for the qualification of eddy current hardware and technique. These procedures provide two basic methods for qualification. The first way is to qualify the equipment or the probe by using the flaw mechanism and method of the pulled tubes from the heat exchangers or the artificial flawed tubes. The second way is to verify the equivalency with the characteristics of the qualified equipment or probe. In this case, the qualified equipment or probe may be modified to substitute or replace instruments or probes without re-qualification provided that the range of essential variables defined in the examination technique specification sheet are met. This study is to describe the result of the comparative performance evaluation of bobbin coil eddy current probes manufactured by KEPCO Research Institute and probes manufactured by a foreign manufacturer. As a result of this study, although there were minor differences between the two kinds of probes, it was evaluated that the two kinds of probes were almost identical in the significant performance characteristics described in the KEPCO Research Institute guideline.