• 제목/요약/키워드: Power Qualify

검색결과 82건 처리시간 0.027초

EMTP를 이용한 제주계통의 여자돌입전류 모델링 (Modeling of Transformer Inrush Current on Jeju Power System using EMTP)

  • 서훈철;여상민;김철환;유영식;조범섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.95-97
    • /
    • 2007
  • Transformer inrush current can cause the voltage drop by source impedance. The accurate modeling and analysis for inrush current is first step to limit the inrush current and improve the power qualify. This paper presents the modeling of transformer inrush current by EMTP-RV using Jeju power system, Korea. The method to model the hysteresis curve of transformer in EMTP-RV is discussed. Simulations demonstrate the verification of modeling of inrush current by comparing the data recorded in field with simulation values and analyzing the harmonics of inrush current.

  • PDF

광대역 전력용 전치증폭기 설계 (Design of Pre-amplifier for Ultrabroadband Power)

  • 김갑기
    • 한국정보통신학회논문지
    • /
    • 제9권7호
    • /
    • pp.1529-1533
    • /
    • 2005
  • 본 논문에서는 광대역전력증폭기에 사용가능한 전치증폭기를 설계하였다. 전치증폭기는 주파수특성과 잡음특성이 우수한 WJ사의 AMl의 사용하였다. 부궤환을 이용하여 100MHz${\~}$3GHz 대역에 걸쳐서 우수한 VSWR 특성과 주파수 특성을 갖도록 설계하였다. 설계된 전치증폭기는 EMC 측정장비와 같은 광대역 i성을 필요로 하는 장비의 전력 증폭기에 활용 가능할 것으로 사료된다.

웨이블릿 변환의 검출 특성을 이용한 전압강하 검출에 관한 연구 (A Study for Voltage Sag Detection Using Detection Characteristic Of Wavelet Transform)

  • 정승복;김재철;설규환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.172-174
    • /
    • 2005
  • Recently, a concern of power qualify increases because of electronic device development and well-being generation. Power quality problems such as voltage sag, harmonics, flicker etc. have adverse effects on electric devices. Therefore, power quality problems have been monitored. This paper studies a detection of voltage sag that is more severer than the others. A voltage sag has been monitored using rms or wavelet method. This paper proposes an advance detection method using wavelet. An error Of Start Point differs error of ending point. We use this difference. So, we respectively revise detection error. Also, we revise multiplying average error rate.

  • PDF

Markov Chain을 이용한 철도계통의 고조파 분석 (Harmonics Analysis of Railroad Systems using Markov Chain)

  • 송학선;이승혁;김진오;김형철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.230-233
    • /
    • 2005
  • This paper proposes power qualify assessment using Markov Chain applied to Ergodic theorem. The Ergodic theorem introduces the state of aperiodic, recurrent, and non-null. The proposed method using Markov Chain presents very well generated harmonic characteristics according to the traction's operation of electric railway system. In case of infinite iteration, the characteristic of Markov Chain that converges on limiting probability Is able to expected harmonic currents posterior transient state. TDD(Total Demand Distortion) is also analyzed in expected current of each harmonic. The TDD for power quality assesment is calculated using Markov Chain theory in the Inceon international airport IAT power system.

  • PDF

순시전압 품질을 고려한 배전계통에서의 신뢰도 평가 (Reliability Evaluation of Power Distribution Systems Considering a Momentary Voltage Quality)

  • 윤상윤;김재철;배주천
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.202-205
    • /
    • 2002
  • This paper presents the reliability evaluation methods considering the momentary voltage quality in power distribution systems. The voltage qualify phenomena deal with this paper are sustained and momentary interruptions and voltage sags. Conventional evaluation indices and methods are summarized for the sustained interruptions, and the assessment methodologies of momentary interruptions and voltage sags are proposed. The evaluation methods are divided into the analytical method and Time Sequential Monte Carlo simulation. The proposed methods are tested using the modified RBTS (Roy Billinton Test System) form and historical reliability data of KEPCO system.

  • PDF

PSO를 이용한 계통연계형 인버터 전류제어기의 자동조정에 관한 연구 (A Study on Tuning of Current Controller for Grid-connected Inverter Using Particle Swarm Optimization)

  • 안종보;김원곤;황기현;박준호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권11호
    • /
    • pp.671-679
    • /
    • 2004
  • This paper presents the on-line current controller tuning method of grid-connected inverter using PSO(particle swarm optimization) technique for minimizing the harmonic current. Synchronous frame PI current regulator is commonly used in most distributed generation. However, due to the source voltage distortion, specially in weak AC power system, current may contain large harmonic components, which increase THD(total harmonic distortion) and deteriorates power quality. Therefore, some tuning method is necessary to improve response of current controller. This paper used the PSO technique to tune the current regulator and through simulation and experiments, usefulness of the tuning method has been verified. Especially in simulating the tuning process, ASM(average switching model) of inverter is used to shorten execution time.

집적정보통신시설 전원 고조파 분석 및 다상화 효과 고찰 (Analysis of Harmonics Waveform Distortion for IDC(Internet Data Center) Power System and effect of multi-Phase)

  • 서정석;이상중;이희영;박정규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.133-138
    • /
    • 2002
  • 정보화 사회가 급속히 확산됨에 따라 국내외 비즈니스 환경 역시 급변하고 있다. 또한 분명한 서비스 품질 향상과 신뢰성의 확보를 위하여 국내외 IDC 사업자는 SLAs(Service Level Agreements) 제도를 시행 또는 추진하고 있다. 인터넷 서버, 계통 및 UPS등에 의한 전원품질은 인터넷 서비스 품질을 결정짓는 주요한 요소의 하나가 되고 있다. 따라서 본 논문에서는 국내 IDC의 고조파 실태를 측정 분석하였고, 다상화(Multi-Phase)를 통한 고조파 저감 효과를 검증하였다.

  • PDF

저풍속도에서도 구동 가능한 현수형 유압식 풍력발전 (driving is Possible In low wind, suspension style & oil pressure wind force Power generation system)

  • 최준영;최홍규;염성배;김용규;이찬재;민성준;최신권
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.35-38
    • /
    • 2008
  • 우리나라는 비교적 국토가 협소하고 산악지방이 많아 다른 나라와는 차별화 된 풍력발전시스템을 도입할 필요가 있다. 기존의 풍력발전시스템은 저풍속의 경우 발전 효율이 급격히 떨어지며 전원 품질에도 많은 문제점을 내포하고 있었다. 이를 개선하기 위하여 한국의 풍속특성에 적합한 현수형의 채택과 전원품질을 개선할 수 있는 유압모터, 동기발전기를 이용한 풍력발전시스템의 모델을 제시하였다.

  • PDF

고화질 Active Matrix OLED 디스플레이를 위한 8비트 데이터 구동 회로 설계 (An 8-bit Data Driving Circuit Design for High-Quality Images in Active Matrix OLEDs)

  • 조영직;이주상;유상대
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.632-634
    • /
    • 2004
  • First for high-qualify images and reducing process-error and driving speed, the designed 8-bit data driving circuit consists of a constant transconductance bias circuit, D-F/Fs by shift registers using static transmission gates, 1st latch and 2nd latch by tristate inverters, level shifters, current steering segmented D/A converters by 4MSB thermometer decoder and 4LSB weighted type. Second, we designed gray amp for power saving. These data driving circuits are designed with $0.35-{\mu}m$ CMOS technologies at 3.3 V and 18 V power supplies and simulated with HSPICE.

  • PDF

전력품질 향상을 위한 순시유효전력 개념을 도입한 제어기 구현 (The Implementation of Controller that introduce the Concept of Instantaneous Active Power for the Improvement of Power Qualify)

  • 정수영;김태현;문승일;권욱현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.209-212
    • /
    • 2002
  • 본 논에서는 기존의 무효전력 보상을 정의하고 순시 유효전력 개념들을 도입한 제어 기법을 제안하였다. 이 기법은 배전 계통에서 비선형 부하로 인한 고조파 제거 기능에 보다 효과적임을 알 수 있다. PSCAD/EMTDC를 이용한 시뮬레이션을 통하여 전통적인 무효전력 보상 기법에 근거한 제어 기법보다 좋은 성능이 있음을 보였다.

  • PDF