• Title/Summary/Keyword: Power Load

Search Result 7,493, Processing Time 0.032 seconds

Digital Load Sharing Method for Converter parallel Operation (컨버터 병렬운전을 위한 디지털 부하분담 기법)

  • Yoo, Kwang-Min;Kim, Won-Yong;Park, Seung-Hee;Lee, Dong-Hoo;Kim, Yun-Sung;Jeong, Yu-Seok;Lee, Jun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.150-157
    • /
    • 2012
  • This paper presents CAN-based parallel-operation and load-sharing techniques for the communication server power supply. With the load information obtained through CAN communication, each modules performs its current control independently and the power unbalance caused by impedance differences of converter modules can be reduced. In conventional method, slave modules are controlled by master module. On the other hand, the proposed load share algorithm uses the Multi-Master method. Therefore, accurate load sharing can be accomplished by the reference structure of each module's average current. Each converter has two stages and it is separated into PFC, which is responsible for harmonic regulation, and LLC resonant converter, which controls output voltage. To verified the performance of the proposed method, two 2KW prototypes has been implemented and experimented.

Power Control of a Hoist System Using Supercapacitor (수퍼캐패시터를 이용한 권상부하 시스템의 전력 제어)

  • Kim, Sang-Min;Yoo, Hyun-Jae;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.11
    • /
    • pp.561-568
    • /
    • 2005
  • This paper proposes a method that distributes the load power and stores the regenerated energy for a hoist-load system using the supercapacitor, an energy storage device. The crane, which is a representative hoist-load system, operates in two modes. The first is the hoist-up mode in which the load container is lifted up: the maximum power is required at the end of acceleration. The second is the hoist-down mode in which the load container is lifted down; the regenerated energy is wasted by the resistor In this paper, the supercapacitor stores the regenerated energy in the hoist-down operation and supplies the peak power demand in the hoist-up operation. The same structure as the commercially available three-phase inverter is proposed as a bidirectional do-dc converter to charge and discharge the supercapacitor. A power control algorithm is proposed to optimize the load sharing between the generator and the supercapacitor. Using the proposed method, it is effected that the generator size can be cut down to one third of the original one; it leads to the reduction of the fuel consumption, noise and air pollution. Simulation and experimental results verify the effectiveness of the Proposed method.

Impact of Electric Vehicle Penetration-Based Charging Demand on Load Profile

  • Park, Woo-Jae;Song, Kyung-Bin;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.244-251
    • /
    • 2013
  • This paper presents a study the change of the load profile on the power system by the charging impact of electric vehicles (EVs) in 2020. The impact of charging EVs on the load demand is determined not only by the number of EVs in usage pattern, but also by the number of EVs being charged at once. The charging load is determined on an hourly basis using the number of the EVs based on different scenarios considering battery size, model, the use of vehicles, charging at home or work, and the method of charging, which is either fast or slow. Focusing on the impact of future load profile in Korea with EVs reaching up 10 and 20 percentage, increased power demand by EVs charging is analyzed. Also, this paper analyzes the impact of a time-of-use (TOU) tariff system on the charging of EVs in Korea. The results demonstrate how the penetration of EVs increases the load profile and decreases charging demand by TOU tariff system on the future power system.

Research of aluminum nitride water load for the 4.6 GHz 500 kW LHCD system of the CFETR

  • Dingzhen Li;Liyuan Zhang;Lianmin Zhao;Fukun Liu;Min Cheng;Huaichuan Hu;Taian Zhou
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3126-3132
    • /
    • 2023
  • To meet the increasing heating needs of the China Fusion Experimental Tokamak Reactor (CFETR), the output power in each Lower Hybrid Current Drive (LHCD) transmission line should be increased from 250 kW to 500 kW. Therefore, a new high-power water load must be developed for the 4.6 GHz 500 kW LHCD system. This paper aims to report the most recent research progress of the water load: aluminum nitride (AlN) ceramic is used as the media material to isolate the water and vacuum, and the radio frequency (RF) simulation results show that the return loss of the water load is less than -25dB at 4.6 GHz over a wide temperature range. Under 500 kW continuous wave (CW) operation, the maximum temperatures of the ceramic and water are separately 67 ℃ and 62 ℃, resulting in thermal deformation of the ceramic of approximately 0.003 mm. Moreover, the AlN water load was tested on the 4.6 GHz 250 kW high-power test bench and found to work well with low reflected power.

High Efficiency Design Considerations for the Self-Driven Synchronous Rectified Phase-Shifted Full-Bridge Converters of Server Power Systems

  • Cetin, Sevilay
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.634-643
    • /
    • 2015
  • This paper presents a high frequency design approach for improving efficiency over a wide load range in the self-driven phase-shifted full-bridge converters for server power systems. In the proposed approach, a detailed ZVS analysis of the lagging leg switches in both the continuous conduction mode (CCM) and the discontinuous conduction mode (DCM) is presented. The optimum dead time and the determination of the appropriate operation mode are given for high efficiency according to the load conditions. Finally, the optimum operation conditions are defined to achieve a high-efficiency. A laboratory prototype operating at 80 kHz, rated 1 kW (12 V-83.3 A), is built to verify proposed theoretical analysis and evaluations. The experimental results show that the maximum efficiency is achieved as 95% and 83.5% at full load and 5% load conditions, respectively.

Smart EVs Charging Scheme for Load Leveling Considering ToU Price and Actual Data

  • Kim, Jun-Hyeok;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.1-10
    • /
    • 2017
  • With the current global need for eco-friendly energies, the large scale use of Electric Vehicles (EVs) is predicted. However, the need to frequently charge EVs to an electrical power system involves risks such as rapid increase of demand power. Therefore, in this paper, we propose a practical smart EV charging scheme considering a Time-of-Use (ToU) price to prevent the rapid increase of demand power and provide load leveling function. For a more practical analysis, we conduct simulations based on the actual distribution system and driving patterns in the Republic of Korea. Results show that the proposed method provides a proper load leveling function while preventing a rapid increase of demand power of the system.

Properties of Multiple Load Flow Solutions and Prevention of Voltage Collapse in System with Induction Motor Load (전압다적해의 특성 및 유도전동기부하를 갖는 계통에 있어서의 전압안정)

  • Park, Jong-Keun
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.1
    • /
    • pp.19-28
    • /
    • 1985
  • As is well known, the power equations of the N-node system have 2N-1 voltage solutions at most. The vlotage solutions are characterized by the introduction of the mode concept in this paper. There are two mode voltages at one node. One is defined as the (+) mode voltage and the other is defined as the (-) mode one. In this paper, we show that the (-) mode voltage responds to the increase of the power condenser almost adversly to the response of the (+) one. We study how to prevent the voltage collapse in the system with the induction motor load. The critical values of the gain and the time constant in case of the continuous power condenser control, and of the unit power condenser and the closing time delay in case of the discontinuous control for the prevention of the voltage collapse, are calculated. The effect of the composition ratio of the impedance load to the induction moter load on the above critical values are also investigated.

  • PDF

Load Characteristic Identification and Transient Stability Analysis Using Neural Network (신경회로망에 의한 부하식별과 과도안정도 해석)

  • Lee, Jong-Pil;Kim, Tae-Eung;Ji, Pyeong-Shik;Nam, Sang-Cheon;Lim, Jae-Yoon;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1127-1129
    • /
    • 1997
  • In this paper, we developed to artificial neural network for load characteristic identification of power system. We can acquire active power and reactive power of individual load depending on the variation of voltage and frequency from the experimentation of a dynamic characteristic of load. The data of the experimental results were be used in learning of ANN. A proposed ANN model is applied to analyze the transient stability. To demonstrate the propriety of the power system transient stability with load model using ANN, the simulation of the two-machine five-bus system is carried out.

  • PDF

A Study on the Characteristic of Capacitor Current by Voltage Harmonics (전압 고조파에 의한 커패시터 전류 특성 해석)

  • Kim, Jong-Gyeum;Kim, Sung-Hyun;Kim, Il-Jung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.148-153
    • /
    • 2009
  • As the increasing of non-linear load, we have a growing interest in power quality. Power quality has come to the voltage quality. Voltage harmonics consist in at the PCC by the non-linear load. Capacitor is generally used for the power compensation and as the passive filter by the serial connection with reactor. Capacitor has low impedance as the frequency increases, so easily fall down by the harmonic component of non-linear load. Small voltage of low-order acts on quite a few at the capacitor by the current increase. In this paper, we measured the magnitude and angle of voltage at the PCC and calculated under the same condition. we checked out that lower voltage of higher order produces current magnification.

A Study of Estimating Local Marginal Power Rate Based on Load Supplying Capability Evaluation Method (최대전력수송량 산정기법을 이용한 지역간 수송여유율에 관한 연구)

  • 남궁재용;이용한;김응상;박동욱;송길영
    • Journal of Energy Engineering
    • /
    • v.7 no.2
    • /
    • pp.172-179
    • /
    • 1998
  • In this paper, an alternative method which can evaluate a marginal power exceeding yearly peak load for each load bus is proposed. The proportion of the marginal power to yearly peak load for each load bus is defined as Local Marginal Power Rate (LMPR). Furthermore, the composite system is separated base on the LMPR. The bottleneck facilities could be found, while the LMPR is estimated. Then, it is possible to provide information concerning improvement in the system reliability by bottleneck facilities. The IEEE Reliability Test System (RTS) is used to demonstrate the effectiveness of the proposed algorithm.

  • PDF