• Title/Summary/Keyword: Power Lift

Search Result 387, Processing Time 0.044 seconds

Reduce Power of Magnetic Contactor using the Two-Level Apply Voltage (Two-Level 전압 인가에 의한 전자접촉기 구동 전력 저감)

  • Kang-Yeol Lee;Hye-Young Na;Seong-Mi Park;Sung-Jun Park;Gyoung-Jong Son
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.5
    • /
    • pp.925-936
    • /
    • 2023
  • Currently, due to the rapid increase in power demand and the increase in capacity of power converters, the capacity of electromagnetic contactors is also increasing, and the burden on SMPS for the power that can drive them is increasing. Although the initial starting operation current of an electromagnetic contactor is significantly larger than the holding current for maintaining contact, most electromagnetic contactors apply the same voltage as the initial starting operation. An electromagnetic contactor must continuously apply a holding current to maintain the contact point, and the larger the capacity, the larger the current must be applied. This paper proposes a two-level magnetic contactor drive that allows setting the initial starting operation current to fully attach the contact point of the magnetic contactor and the holding current to maintain subsequent operation. In addition, a low-cost drive topology of analog and digital methods was proposed for various field applications, and an algorithm based on the ripple of the excitation current was proposed to determine whether the magnetic contactor was opened or closed without using a separate contact point. The feasibility of the proposed method was proven through Psim simulation experiments.

Fluctuating Wind Pressures on High Aspect Ratio Circular Cylinder

  • Keisuke Miura;Masahiro Matsui
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.4
    • /
    • pp.277-286
    • /
    • 2022
  • In this study, The POD technique was applied to the fluctuating wind pressure of high aspect ratio circular cylinder to consider about its organizational structure, and considered about the characteristics of the fluctuating wind force obtained by synthesized the POD modes.

A Study on the Development of Circular Hub type offshore wind power generation (Circular Hub타입 해상용 풍력발전기 개발에 관한 연구)

  • Lee, Byeongseong;Kim, Namhun;Oh, Jinseok;Kim, Donghyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.183.2-183.2
    • /
    • 2010
  • 본 개발에서의 해상용 풍력발전기는 크게 허브와 블레이드를 합한 상부 구조물, 전기 발전기와 연결 조인트의 중간구조물, 각종 제어 장치가 들어있는 제어박스로 나누어진다. 상부 구조물은 Circular Hub 타입의 Darrieus 형상으로 양력(lift)을 이용한 회전력이 발생하며, Circular Hub 타입은 기존의 허브와 블레이드를 연결하여주는 암(arm)에 의해 유발되는 항력토크를 최소화 하기 위한 신개념 형상설계가 이루어 졌으며, 저속에서 우수한 회전특성을 가진다. 이는 바람을 받아 기계적 에너지로 전환 하는 역할을 하며, 풍력발전기의 성능에 직접적인 영향을 미친다. 중간구조물의 전기발전기는, 상부에서 발생된 기계적 에너지를 이용하여 전기적 에너지로 전환 하는 역할을 수행한다. 이렇게 전환된 전기적 에너지는 하부의 제어박스를 거쳐서 해상용 부이(buoy)의 하단에 위치한 베터리 뱅크로 전달, 저장되어 부이에서 쓰이는 전력을 충당하게 된다. 한편 본 개발은 풍력발전기의 공력하중 해석과 로터블레이드의 설계, 풍력발전기의 구조, 진동해석, MPPT 제어컨트롤러와 Breaking controller, 풍동 및 차량시험을 통한 성능평가 및 분석 등의 순으로 개발을 수행하였다.

  • PDF

A Study on the Health Care of the Aged in View of the Kings of the Joseon Dynasty (조선 군왕의 삶으로 본 고령화시대 건강증진 방법에 대한 고찰)

  • Lee, Hai-Woong;Kim, Hoon
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.19 no.2
    • /
    • pp.146-160
    • /
    • 2006
  • Background and Aim : As one of the World Cultural Heritage, Joseonwangjosillok is a history book including general state affair, social affair, economy, astronomical and atmospheric phenomena, art, music, eat. as well as the very private life of the king. With Joseonwangjosillok, we will look into health and death of the king and apply it to the regimen and recommended life-style of the aged. Materials and Method : With the archive of Joseonwangjosillok and medical text books such as Donguibogam Huang Di Nei Jing as reference, we tried to inquire the work and life of the kings of the Joseon dynasty, find connection with the regimen recommended life-style, and suggest medical guidelines for the aged as geriatric society is coming. Result : The Kings of the Joseon dynasty had omnipotent power, so that they lived quite much better lift than common people. But their average lifetime is estimated to be no better than that of ethers. Probably overwork, mental stress, rich fatty diet and lack of exercise took healthy life from them. Conclusion : Even if they had unlimited power, the state-of-the-art medical treatment hardly helped the Kings live better and longer life than common people. To keep and promote healthy lift for the aged, they need moderate exercise, appropriate rest, balanced diet, seen dissolving with reasonable environment.

  • PDF

Effects of Microwave Induction on the Liftoff and NOx Emission in Methane Micro Jet Flames (메탄 마이크로 제트화염의 부상과 NOx 배출에 대한 마이크로파 효과)

  • Jeon, Young Hoon;Lee, Eui Ju
    • Journal of the Korean Society of Combustion
    • /
    • v.21 no.2
    • /
    • pp.22-28
    • /
    • 2016
  • High efficient and environment friendly combustion technologies are used to be operated an extreme condition, which results in unintended flame instability such as extinction and oscillation. The use of electromagnetic energy is one of methods to enhance the combustion stability and a microwave as electromagnetic wave is receiving increased attention recently because of its high performance and low-cost system. In this study, an experiment was performed with jet diffusion flames induced by microwave. Micro jet was introduced to simulate the high velocity of industrial combustor. The results show that micro jet flames had three different modes with increasing oxidizer velocity; attached yellow flame, lifted flame, and lifted partially premixed flame. As a microwave was induced to flames, the overall flame stability and blowout limit were extended with the higher microwave power. Especially the interaction between a flame and a microwave was shown clearly in the partially premixed flame, in which the lift-off height decreased and NOx emission measured in post flame region increased with increasing microwave power. It might be attributed to increase of reactivity due to the abundance of radical pool and the enhanced absorption to thermal energy.

Experiment and Flow Analysis of the Flow Coefficient Cv of a 1 inch Ball Valve for a Thermal Power Plant (화력발전소용 1인치 볼 밸브 유량계수 Cv에 관한 유동해석 및 실험에 관한 연구)

  • Kang, Chang-Won;Yi, Chung-Seob;Lee, Chi-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.3
    • /
    • pp.109-115
    • /
    • 2019
  • The purpose of this study was to analyze and test the flow rate of a 1-inch ball valve used in a thermal power plant. To identify the flow-rate characteristics, numerical analysis was conducted and an experimental apparatus of the valve flow rate coefficient was used to compare the flow coefficient Cv values. To determine the internal pressure distribution, the sites of opening ball valves and flow fields were investigated. In particular, a smaller the valve opening resulted in a more complicated the flow field of the ball. The valve flow characteristic test showed that the Cv value and flow rate increased with increasing valve-opening rate and the secondary function was performed. The pressure drop increased as the valve opening rate decreased. In addition, the experimental results for the flow analysis are similar to the numerical analysis results.

A Study on the Engineering Design for 250kW-Grade Waste Gas Heat Recovery (250kW급 폐열회수 시스템 공정설계에 관한 연구)

  • Kim, Kyoung Su;Bang, Se Kyoung;Seo, In Ho;Lee, Sang Yun;Jeong, Eun Ik;Yi, Chung Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.5
    • /
    • pp.90-95
    • /
    • 2019
  • This study aims to gain the design data through the process design of the organic Rankine cycle, which can produce 250kW of electric power through waste heat recovery. In this study, a simulation was conducted using APSEN HYSYS to make the model for the process design of the 250kW-class waste heat recovery system. For the thermodynamic model, the test was conducted with hot water as the heat source, the water steam as the cooling water for the cooler, and the refrigerant R245FA in the cycle. In the final design, it was expected and found from the simulation that the cycle efficiency was 12.62% and that 250kW of power was produced considering the margin of 80%.

Construct of Electronics Load System using the Multi-level Interiver Converter (다중전류레벨 인터리버 컨버터를 이용한 전자부하 시스템 구성)

  • Moon, Hyeon-Cheol;Song, Kwang-Cheol;Lee, Chang-Ho;Park, Seong-Mi;Park, Sung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.6_2
    • /
    • pp.989-998
    • /
    • 2020
  • Recently, demands for large-capacity electronic loads are increasing in various industries such as a reliability test for the performance of a DC power supply device or a dummy-load for improving the stability of an independent microgrid to be actively built in the future. The electronic load required in these various fields requires an operation such as a continuously variable resistance load while minimizing the switching harmonic component generated in the electric load current in order to reduce the influence of interference from the load peripheral device. Electronic loads require a system that minimizes switching current ripple for load control. Therefore, in this paper, we propose a three-level module converter structure to reduce the current ripple of an electronic load, and a multilevel interleaved power converter topology to reduce the current ripple. The validity of the proposed electronic load, 3-level 6 interleaver converter, was verified by simulation and experiment. In addition, the user's convenience was provided by applying the emotional command curve interface method.

MG Operation Technique based on DC-Grid Stability using ESS (ESS를 활용한 DC-Grid 안정성 기반 MG 운영 기법)

  • Jong-Cheol Kim;Chun-Sung Kim;Yong-Un Park;Seong-Mi Park;Sung-Jun Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_3
    • /
    • pp.1269-1278
    • /
    • 2023
  • This paper presents an operational technique that can secure the stability of DC-Grid centering on MG operated based on ESS in multiple MG where three DC-based microgrid(MG) are interconnected. MG1(PV 600kWp, ESS 1.5MWh) has an 830Vdc grid voltage, MG2(PV 300kWp, ESS 1.1MWh) and MG3(PV 100kWp, ESS 500kWh) are DC-based MG with a 750Vdc grid voltage, and MG1 and MG2, 3 are linked by separate DC/DC converters (BTB). In order to keep different grid voltages stable, the power transmission capacity between MG1 and two MG(MG2, MG3) connected with an independent BTB converter was adjusted to secure the overall stability of the system, and this was verified by confirming that the surplus capacity of ESS was maintained in actual operation.

Power Supply System Configuration for Preventing Corrosion on Pipeline using a Low-cost SMPS Chip

  • Sung-Gi Chae;Jun-Jae An;Gwang-Cheol Song;Seong-Mi Park;Sung-Jun Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.5
    • /
    • pp.1099-1109
    • /
    • 2024
  • As a wide range of industries using iron, such as water and sewerage pipes, gas pipelines, heat pipes, electric engines, communication pipes, and oil pipelines, rapidly become active, there is a demand for reliability and low cost of DC power supplies that can prevent corrosion of pipe networks. In particular, high-efficiency corrosion prevention systems due to changes in the perception of carbon emissions and energy saving are essential elements. Therefore, the construction of a switching-type corrosion current controller is being activated. Also, in such systems, DC/DC converters capable of multi-channel current control are demanded for corrosion prevention functions and uniform consumption of sacrificial anodes. This paper proposes a new current supply system for preventing pipeline corrosion using a low-cost SMPS dedicated chip. The proposed method can maintain excellent parallel operation function, protection function, and response speed by configuring a current controller using a hybrid method using analog and digital. The proposed method verified its superiority through simulations and experiments.