• Title/Summary/Keyword: Power Imbalance

Search Result 275, Processing Time 0.024 seconds

A Novel Control Algorithm of a Three-phase Four-wire PV Inverter with Imbalance Load Compensation Function

  • Le, Dinh-Vuong;Kim, Chang-Soon;Go, Byeong-Soo;Park, Minwon;Yu, In-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1131-1137
    • /
    • 2018
  • In this paper, the authors suggest a new control algorithm for a three-phase four-wire photovoltaic (PV) inverter with imbalance load compensation function using conventional proportional-integral (PI) controllers. The maximum power of PV panel is calculated by the MPPT control loop. The reference varying signals of current controllers are transformed to two different rotating frames where they become constant signals. Then simple PI controllers are applied to achieve zero steady-state error of the controllers. The proposed control algorithm are modeled and simulated with imbalance load configuration to verify its performance. The simulation results show that the maximum PV power is transferred to the grid and the imbalance power is compensated successfully by the proposed control algorithm. The inverter has a fast response (~4 cycles) during the transient period. The proposed control algorithm can be effectively utilized to the three-phase four-wire inverter with imbalance load compensation function.

Compensation of Position Error due to Amplitude Imbalance in Resolver Signals

  • Hwang, Seon-Hwan;Kwon, Young-Hwa;Kim, Jang-Mok;Oh, Jin-Seok
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.748-756
    • /
    • 2009
  • This paper presents a compensation algorithm for position error due to an amplitude imbalance between resolver output signals. Resolvers are typically used to obtain absolute position information for motor drive systems in severe environments. Position error is caused by an amplitude imbalance of the resolver output signals. As a result, the d- and q-axis currents of synchronous reference frame have periodic ripples in the stator fundamental frequency in permanent magnet synchronous motor (PMSM) drive systems. Therefore, this paper proposes a compensation algorithm to reduce the position error generated by the amplitude imbalance. The proposed method does not require any additional hardware, and reduces computation time with a simple integral operation according to rotor position. In addition, the position error can be directly compensated for by the estimated position error. The effectiveness of the proposed compensation algorithm is verified through several simulations and experiments.

A New Required Reserve Capacity Determining Scheme with Regard to Real time Load Imbalance

  • Park, Joon Hyung;Kim, Sun Kyo;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.511-517
    • /
    • 2015
  • Determination of the required reserve capacity has an important function in operation of power system and it is calculated based on the largest loss of supply. However, conventional method cannot be applied in future power system, because potential grid-connected distributed generator and abnormal temperature cause the large load imbalance. Therefore this paper address new framework for determining the optimal required reserve capacity taking into account the real time load imbalance. At first, we introduce the way of operating reserve resources which are the secondary, tertiary, Direct Load Control (DLC) and Load shedding reserves to make up the load imbalance. Then, the formulated problem can be solved by the Probabilistic Dynamic Programming (PDP) method. In case study, we divide two cases for comparing the cost function between the conventional method and the proposed method.

A High-efficiency Method to Suppress Transformer Core Imbalance in Digitally Controlled Phase-shifted Full-bridge Converter

  • Yu, Juzheng;Qian, Qinsong;Sun, Weifeng;Zhang, Taizhi;Lu, Shengli
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.823-831
    • /
    • 2016
  • A high-efficiency method is proposed to suppress magnetic core imbalance in phase-shifted full-bridge (PSFB) converters. Compared with conventional solutions, such as controlling peak current mode (PCM) or adding DC blocking capacitance, the proposed method has several advantages, such as lower power loss and smaller size, because the additional current sensor or blocking capacitor is removed. A time domain model of the secondary side is built to analyze the relationship between transformer core imbalance and cathode voltage of secondary side rectifiers. An approximate control algorithm is designed to achieve asymmetric phase control, which reduces the effects of imbalance. A 60 V/15 A prototype is built to verify the proposed method. Experimental results show that the numerical difference of primary side peak currents between two adjacent cycles is suppressed from 2 A to approximately 0 A. Meanwhile, compared with the PCM solution, the efficiency of the PSFB converter is slightly improved from 93% to 93.2%.

Developing of Super Junction MOSFET According to Charge Imbalance Effect (전하 불균형 효과를 고려한 Super Junction MOSFET 개발에 관한 연구)

  • Kang, Ey Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.10
    • /
    • pp.613-617
    • /
    • 2014
  • This paper was analyzed electrical characteristics of super junction power MOSFET considering to charge imbalance. We extracted optimal design and process parameter at -15% of charge imbalance. Considering extracted design and process parameters, we fabricated super junction MOSFET and analyzed electrical characteristics. We obtained 600~650 V breakdown voltage, $224{\sim}240m{\Omega}$ on resistance. This paper was showed superior on resistance of super junction MOSFET. We can use for automobile industry.

Analysis and Control of Neutral Point Current Deviation in Grid Tied 3-Level NPC Converter under Various Grid Unbalanced Conditions (다양한 불평형 계통 상황에서 계통 연계형 3-레벨 NPC 컨버터의 중성점 전류 변동에 대한 해석 및 제어)

  • Choi, Jaehoon;Suh, Yongsug
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.5
    • /
    • pp.385-393
    • /
    • 2020
  • This study introduces an analysis and control method for the variation of neutral point current in a grid-tied three-level neutral point clamped (NPC) converter under various grid imbalance operating conditions. Various fault cases with unbalanced amplitude and phase are systematically categorized and described using a unified metric called the imbalance factor. The fundamental component of neutral point current is generated under grid imbalance cases. The pattern and behavior of this fundamental component of neutral point current highly depend on the imbalance factor regardless of the particular type of grid fault cases. The control scheme for regulating the negative sequential component of AC input current effectively reduces the size of the fundamental component of neutral point current under a wide range of grid imbalance cases. The control scheme will enable a grid-tied three-level NPC converter to operate reliably and stably under various types of grid faults.

A Dynamic Power Distribution Strategy for Large-scale Cascaded Photovoltaic Systems

  • Wang, Kangan;Wu, Xiaojie;Deng, Fujin;Liu, Feng
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1317-1326
    • /
    • 2017
  • The cascaded H-bridge (CHB) multilevel converter is a promising topology for large-scale photovoltaic (PV) systems. The output voltage over-modulation derived by the inter-module active power imbalance is one of the key issues for CHB PV systems. This paper proposed a dynamic power distribution strategy to eliminate the over-modulation in a CHB PV system by suitably redistributing the reactive power among the inverter modules of the CHB PV system. The proposed strategy can effectively extend the operating region of the CHB PV system with a simple control algorithm and easy implementation. Simulation and experimental results carried out on a seven-level CHB grid-connected PV system are shown to validate the proposed strategy.

Balance of Power and the Relative Military Capacity - Empirical Analysis and Implication to North East Asia - (세력균형(power balance)에서의 군사력 수준과 동북아시아에 주는 함의)

  • Kim, Myung-soo
    • Strategy21
    • /
    • s.38
    • /
    • pp.112-162
    • /
    • 2015
  • This study began to confirm or review the balance of power theory by applying scientific methods through experiential cases. Though there are several kinds of national power, this study supposes military power as a crucial power when it comes to war and peace. This research covered balance and imbalance through comparing relative military power between nations or nations' group. Comparison of relative military power can be achieved by statistically processing the values of which has been converted into the standard variables in same domain, then calculating the values of nation's power which has been synthesized different experiential factors. In addition, the criteria of experiential experiment is highly dedicated to European countries, USA, Japan prior to 1st and 2nd World War, as well as USA, Soviet Union and North East Asia during Cold War era. In addition, the balance of power theory has been redefined to review the action of the state upon the changes of power as mentioned in the theory. To begin with, the redefined theory states that relative level of military power between nations defines the consistency of peace and balance of power. If military power is enough to be on the range of level required to keep the power in equilibrium, peace and balance can be achieved. The opposite would unbalance the military power, causing conflicts. While the relative military level between nations change, nations seek to establish 'nations group' via military cooperation such as alliance, which also shift relative military power between nations group as well. Thus, in order to achieve balance of power, a nation seeks to strengthen its military power(self-help), while pursuing military cooperation(or alliance). This changes relative military power between nations group also. In other words, if there exists balance of power between nations, there is balance of power between nations group as well. In this theory, WWI and II broke out due to the imbalance of military force between nations and nations group, and reviewed that due to the balance of military force during the Cold War, peace was maintained. WWI was resulted from imbalance of military cooperation between two powerful states group and WWII was occurred because of the imbalance among the states. Peace was maintained from cooperation of military power and balance among the states during the Cold War. Imbalance among continental states is more threatening than maritime states and balance of power made by army force and naval force also is feasible. Also the outcomes of two variables are found military power balanced ratio of military power for balance is 67% when variable ratio of balance is 100% and standard value for balance is 0.86. Military power exists in a form of range. The range is what unstabilized the international system causing nations to supplement their military powers. These results made possible the calculation and comparison between state's military power. How balance of power inflicted war and peace has been studied through scientific reviews. Military conflict is highly possible upon already unbalanced military powers of North East Asian countries, if the US draws its power back to America. China and Japan are constantly building up their military force. On the other hand, Korean military force is inferior so in accordance to change of international situation state's survival could be threatened and it is difficult to achieve drastic increase in military force like Germany did. Especially constructing naval force demands lots of time; however but has benefit that naval force can overcome imbalance between continental states and maritime states.

A method for simultaneous quench of hybrid type superconducting fault current limiter (Hybrid형 초전도 한류기의 동시퀜치 유도방안)

  • Choi, Hyo-Sang;Hyun, Ok-Bae;Kim, Hye-Rim;Park, Kwon-Bae;Hwang, Si-Dole
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.916-917
    • /
    • 2001
  • We investigated the properties of a hybrid type superconducting fault current limiter (SFCL), which consists of a transformer with multiple secondary windings and resistive $YBa_2Cu_3O_7$ (YBCO) thin film stripes. The secondary windings of the transformer were coupled with each other, and a superconducting current limiting unit of YBCO stripes was connected to each of them as a switch. Simple connection in series of SFCL units tends to produce imbalance in power among the units due to slight differences in quench current. In current design, magnetic coupling between the SFCL units provides a solution to power dissipation imbalance, inducing simultaneous quench by current redistribution in the YBCO films.

  • PDF

Development of Switching Power Module with Integrated Heat Sink and with Mezzanine Structure that Minimizes Current Imbalance of Parallel SiC Power Semiconductors (SiC 전력반도체의 병렬 구동 시 전류 불균형을 최소화하는 Mezzanine 구조의 방열일체형 스위칭 모듈 개발)

  • Jeong-Ho Lee;Sung-Soo Min;Gi-Young Lee;Rae-Young Kim
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.28 no.1
    • /
    • pp.39-47
    • /
    • 2023
  • This paper applies a structural technique with uniform parallel switch characteristics in gates and power loops to minimize the ringing and current imbalance that occurs when a general discrete package (TO-247)-based power semiconductor device is operated in parallel. Also, this propose a heat sink integrated switching module with heat sink design flexibility and high power density. The developed heat dissipation-integrated switching module verifies the symmetry of the parasitic inductance of the parallel switch through Q3D by ansys and the validity of the structural technique of the parallel switch using the LLC resonant converter experiment operating at a rated capacity of 7.5 kW.