• Title/Summary/Keyword: Power Generation Facilities

Search Result 329, Processing Time 0.033 seconds

Doppler Rader Location of Weather Information System for Power System Operation (전력계통(電力系統) 기상정보(氣象情報)시스템의 도플러레이다 위치(位置) 선정(選定))

  • Kim, Yeong-Han;Lee, Hyo-Sang;Kim, Jai-Young
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.206-210
    • /
    • 1989
  • With the economy expands and the increasing living standard of people, the better quality of electricity which is closely related with weather conditions should be supplied to the customers especially using precised facilities. In this paper, the configuration of the weather information system and its application to the power system operation are generally introduced. And also, a method with test result is presented to find the suitable radar coverage area including the condition of electromagnetic wave shut off.

  • PDF

A Study on the Application Method of Facility Classification System for the Development of Asset Management System for Power Generation Structures (발전구조물의 자산관리 시스템 구축을 위한 시설물분류체계 활용방안에 관한 연구)

  • Jeon, Seokhyeon;Jeong, Jeongsik;Ahn, Jinhee;Kim, Changhak
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.2
    • /
    • pp.113-118
    • /
    • 2019
  • Recently, the maintenance concept of infrastructure has been changed from the stability management of the structure determined by the safety inspection of the existing facilities to the asset management related to evaluating and managing the performance of the facilities. For management of the property of the facilities, it is necessary to efficiently classify their information for the maintenance and service level of the facilities and to manage them. In the case of power plant facility, especially, it is a complex structure, which is constructed in a various component and detail. In this study, therefore, the components of power plant facility were classified into facilities, spaces, parts, and elements considering the type of integrated construction classification system in Korea. To reflect the deterioration rate of the facility in accordance with environmental conditions such as airborne salt and humidity etc., it was classified by adding direction, interior, and exterior condition of each component not to be considered in the existing classification system for its effective and systematic maintenance, since it is generally located in the coastal area due to the operation of the power generation structure. The classification system developed in this study can be used as fundamental data for development of the computer system for asset management of power plant facility.

Analysis of Effect of HVDC Transmission System on the Transient Stability (HVDC 송전망이 대형발전단지의 과도안정도에 미치는 영향 분석)

  • Jeon, Hyeok-Mo;Chun, Yeong-Han
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • The characteristics of Korean power systems are large capacity of generation sites and concentrated load in Seoul metropolitan area. According to the national generation facility plan, more generation facilities are needed to be constructed as the electrical demands are forecasted to increase. Moreover, the size of generation sites are expected to increase, too. Therefore transient stability problems become worse and worse. Recently, the necessity of HVDC has been raised to overcome the difficulty of constructing HVAC transmission lines. This paper shows the analysis of transient stability when HVDC transmission system is added to the power system consisting of large generation sites.

Propagation of Lightning Surges on Power AC Lines through Distribution Transformers (배전용 변압기를 통한 저압전원선으로의 뇌서지 전파)

  • Lee, Bok-Hee;Lee, Su-Bong;Lee, Dong-Moon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.468-471
    • /
    • 2002
  • A strong need to improve the quality of electric power is increased because of increasing use of the sensitive and small-sized electronic devices. The surges on the low-voltage ac power lines are induced by nearby lightning return strokes, and the facilities for HA, OA, FA, ME as well as computer are easily damaged by high-voltage transients. The behaviors of lightning surge characteristics transferred from the primary winding to the secondary winding in distribution transformers using a Marx generator were experimentally investigated. The transfer characteristics of lightning surge associated with a custom service ground of secondary side were also examined.

  • PDF

Design of the Electronic Anti-Fouling System for a Wave Energy Converter

  • Lee, Ji-Young;Oh, Jin-Seok
    • Journal of Navigation and Port Research
    • /
    • v.33 no.7
    • /
    • pp.501-504
    • /
    • 2009
  • There are many difficulties to supply constant power to marine facilities which operate in the sea. Especially, there is a limit to stand alone power supply systems due to the influence of weather conditions. That's why a hybrid power supply system is required to overcome these problems. This paper will describe an Electronic Anti-Fouling System (EAFS) to maximise the power efficiency for a solar - wave hybrid power generation system. A main factor reducing the efficiency of a Wave Energy Converter (WEC) is due to the attachment of aquatic life forms. Therefore the aim of this research is to develop a simulation programme to enable the design of more efficient EAFS for hybrid power generation systems and to provide valuable data for production of more efficient EAFS.

Measuring the benefits from integrated energy business-based combined heat and power plant as a decentralized generation source with a focus on avoiding the damages caused by large-scale transmission facilities (분산형 전원으로서의 집단에너지사업 열병합발전의 송전망 피해 회피편익 추정)

  • Kim, Hyo-Jin;Choi, Hyo-Yeon;Yoo, Seung-Hoon
    • Journal of Energy Engineering
    • /
    • v.24 no.3
    • /
    • pp.67-73
    • /
    • 2015
  • Almost base-loaded power plants such as flaming coal and nuclear energy require large-scale transmission facilities (LTFs) in order to send electricity to remote consumption areas. As well known, LTFs incur various social costs. However, a decentralized generation source such as integrated energy business (IEB)-based combined heat and power (CHP) plant is located in nearby electricity-consuming area, and thus it does not demand LTFs, providing the benefits from avoiding the damages caused by them. This study attempts to measure the benefits of avoiding the damages from the LTFs by the use of the contingent valuation (CV) method. To this end, a national survey of randomly chosen 1,000 households was implemented and the public's willingness to pay (WTP) for substituting consumption of electricity generated from flaming coal-fired power plant, currently a dominant generation source in Korea, with that produced from IEB-based CHP plant. The results show that the WTP for the substitution is estimated to be about 41.4 won per kWh. Considering that this value amounts to 33% of the average price of residential electricity in 2014, the external benefit of the IEB-based CHP as a decentralized generation appears to be large.

A Case Study for Analyzing the Optimal Location for A Solar Power Plant via AHP Analysis with Fine Dust and Weather Information (미세먼지와 기상정보 기반의 AHP 분석을 통하여 태양광 발전소 최적입지선정에 대한 사례연구)

  • Lee, Geon-ju;Lee, Gi-Hyun;Kang, Sung-Woo
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.4
    • /
    • pp.157-167
    • /
    • 2017
  • Solar energy has been known as a successful alternative energy source, however it requires a large area to build power generation facilities compared to other energy sources such as nuclear power. Weather factors such as rainy weather or night time impact on solar power generation because of lack of insolation and sunshine. In addition, solar power generation is vulnerable to external elements such as changes in temperature and fine dust. There are four seasons in the Republic of Korea hereby variations of temperature, insolation and sunshine are broad. Currently factors that cause find dust are continuously flowing in to Korea from abroad. In order to build a solar power plant, a large area is required for a limited domestic land hereby selecting the optimal location for the plant that maximizes the efficiency of power generation is necessary. Therefore, this research analyze the optimal site for solar power generation plant by implementing analytic hierarchy process based on weather factors such as fine dust. In order to extract weather factors that impact on solar power generation, this work conducts a case study which includes a correlation analysis between weather information and power generation.

PV Inverter Operation according to DC Capacitor Aging (직류 커패시터 노후화에 따른 PV 인버터 동작)

  • Yongho Yoon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.2
    • /
    • pp.149-155
    • /
    • 2023
  • Photovoltaic power generation is the most familiar power generation facility among new and renewable energies, and its supply began to expand about 10 years ago, and at this point, interest in solutions and technologies for system maintenance management is increasing. In particular, it is necessary to take measures to maximize the overall efficiency of the solar power generation system, whether or not there is an abnormality in the solar power generation system, and when to replace parts. The PV inverter, one element of the photovoltaic power generation system, is a power conversion system that relies on power switching devices, and DC-Link capacitors are used according to the configuration of DC/DC converters and DC-AC inverters. These DC capacitors also affect system safety (Safety) through renewable energy facilities due to the decrease in power generation of PV inverters, power loss, and increase in harmonics (THD, total distortion of AC output current) due to aging and deterioration due to long-term use. factors can be analyzed. Therefore, in this paper, the PV inverter operating characteristics according to the DC capacitor capacity state currently operating in the photovoltaic power generation system were considered, and research contents were proposed to secure the safety and reliability of renewable energy facilities.

Self-Adaptive Smart Grid with Photovoltaics using AiTES (AiTES를 사용한 태양광 발전이 포함된 자가 적응적 스마트 그리드)

  • Park, Sung-sik;Park, Young-beom
    • Journal of Platform Technology
    • /
    • v.6 no.3
    • /
    • pp.38-46
    • /
    • 2018
  • Smart Grid is an intelligent power grid for efficiently producing and consuming electricity through bi-directional communication between power producers and consumers. As renewable energy develops, the share of renewable energy in the smart grid is increasing. Renewable energy has a problem that it differs from existing power generation methods that can predict and control power generation because the power generation changes in real time. Applying a self-adaptative framework to the Smart Grid will enable efficient operation of the Smart Grid by adapting to the amount of renewable energy power generated in real time. In this paper, we assume that smart villages equipped with photovoltaic power generation facilities are installed, and apply the self-adaptative framework, AiTES, to show that smart grid can be efficiently operated through self adaptation framework.

Design of Marine Transport Facilitie's Anti-Fouling System of Wave Power Generation (해양교통시설물의 파력발전 방오장치 설계)

  • Kim, Ji-Yoon;Jo, Kwan-Jun;Han, Sung-Hun;Oh, Jin-Seok
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.192-192
    • /
    • 2011
  • For the safety of vessels sailing Marine Transport Facility announces sea route, reefs or shallow water. Photovoltaic, independent power system, installation in the general Marine Transport Facilities to be used in the marine lantern. Due to install of communications, controls, power consumption inceases. And the weather of cloudy day or rainy, generation of electricity is decrease. Recently, power system of marine facility using a hybrid generation system, photovoltaic generation system and wave power generation system. But increase of adhered shellfish inside the water column, is the cause of the reduction of efficiency. So study was conducted to Single channel AFS(Anti-Fouling system). In this paper we offer the Multi channel AFS for Marine Transport Facility and have simulated. Improve the accuracy of the research, we using the result of anode, in the experiment were actually in the buoy, is based on simulation. The experimental results is shown every anode's, in the Marine Transport Facility, ionization was conducted identically.

  • PDF