• 제목/요약/키워드: Power Fluctuation

검색결과 600건 처리시간 0.023초

지중 열반응 현장시험에서 소비전력 변동의 영향 (Influences of Power Fluctuation on In-Situ Ground Thermal Response Testing)

  • 김진상;박근우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.707-712
    • /
    • 2006
  • Knowing the ground thermal conductivity is very importnat in designing ground heat exchangers. Knowledge of the ground soil and rock composition information dose not guarantee the prediction of accurate thermal information. In Situ testing of ground heat exchangers is becoming popular. However, in situ testing are performed at construction sites in real life. Adequate data collection and analysis are not easy mainly due to poor power quality. Power fluctuation also causes the fluctuation of received data. The power quality must be maintained during the entire in situ testing processes. To accurately analyse the test data, the understanding of the response of the power fluctuation is essential. Testing under the power quality varied by tester is very difficult. Analyzing power variation by numerical simulation is a realistic option. By varying power in a sinosuidal manner, its effects on predicting thermal conductivity from thermal response plots made from the test data are examined.

  • PDF

A Parallel Processing Uninterruptible Power Supply for Sudden Voltage Fluctuation for Computer Applications

  • 이수원;고성훈;이성룡;정용채;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2009년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.287-289
    • /
    • 2009
  • This paper deals with a parallel processing uninterruptible power supply (UPS) for sudden voltage fluctuation in computer applications to integrate power quality improvement, load voltage stabilization and UPS. To reduce the complexity, cost and number of power conversions, which results in higher efficiency, only one voltage-controlled voltage source inverter (VCVSI) is used. The system provides sinusoidal voltage at the fundamental value of 220V/60Hz for the load during abnormal utility power conditions or grid failure. Also, the system can be operated to mitigate the harmonic current and voltage demand from nonlinear loads and provide voltage stabilization for loads when sudden voltage fluctuation occur, such as sag and swell. System operation simulation demonstrates that the system protects against outages caused by abnormal utility power conditions and sudden voltage fluctuations and changes.

  • PDF

1/f 수준 별 음악 자극이 감정 노동 종사자의 심장 반응에 미치는 효과 (Heart Response Effect by 1/f Fluctuation Sounds for Emotional Labor on Employee)

  • 전병무;황민철
    • 감성과학
    • /
    • 제18권3호
    • /
    • pp.63-70
    • /
    • 2015
  • 본 연구는 1/f fluctuation의 ${\alpha}$기울기 따라 구성된 사운드를 들었을 때 감정 스트레스 업무에 종사하고 있는 피험자들의 심박 변화를 확인하고자 하였다. 기존의 연구에서는 주로 사용자의 심리상태 안정시키는 효과 또는 생리적 안정성에 1/f fluctuation의 ${\alpha}$기울기가 관계가 있는 것으로 보고되었다. 본 연구에서는 1/f fluctuation 수준을 총 3가지 나누어 제작한 사운드를 독립변수로 사용하였다. 독립변수는 감정노동 종사자에게 제시하여 그에 따른 심장반응을 측정하였다. 종속변수는 네 가지로 BPM(Beat Per Minute), VLF(Very Low Frequency), SDNN(Standard Deviation of NN intervals), 그리고 HF(High Frequency) 파워(Power)값을 확인하였다. 분석결과 기울기가 3인 1/fluctuation 사운드는 각성효과를 보였다. 기울기 1, 2인 사운드는 이완효과가 있는 것을 통계적으로 검증하였다. 이러한 1/f fluctuation 사운드의 특성을 활용해 감정 노동자들의 스트레스를 완화시키기 위한 서비스에 응용될 수 있을 것으로 사료된다.

단기 평균값을 이용한 풍력발전 출력 평활화 제어 효과 분석 (Analysis on the Effectiveness of Wind Power Fluctuation Based on Short-term Average Power)

  • 윤태섭;김일환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 추계학술대회 논문집
    • /
    • pp.206-207
    • /
    • 2016
  • The intermittent characteristics of wind power (WP) may have negative effect on grid stability, especially in weak grid. WP fluctuation rate can be reduced by using energy storage system (ESS) through charging and discharging. The operation of ESS will decide its losses and lifetime of batteries. From this point, this paper proposes WP smoothing control by using short-term average of WP. In this case, the ESS will only operate at high WP fluctuation rate. Then, the output power of ESS will be estimated by short-term average value. The effectiveness of proposed method will be verified by comparing with conventional method. The simulation results will be carried out by using Matlab program.

  • PDF

필터뱅크기법에 기반한 전력신호 플리커 검출 (Power Signal Flicker Detection Based on Filter Bank Technique)

  • 최훈;배현덕
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.179-193
    • /
    • 2016
  • In power quality monitoring, voltage fluctuation is one of the power quality problems, which cause light flickers. To determine the flicker severity, the flicker meter concept was developed in an IEC 61000-4-15 standard. Generally, voltage fluctuations are described as an amplitude modulation(AM). The flicker meter of IEC 61000-4-15 as an international standard for flicker measurement recommends square demodulation method to detect flicker signals from voltage fluctuation signals. This paper suggests a new effective method using filter bank to detect and estimate flicker signals, which do not need square demodulation. For the accurate detection of flicker signals, the filter bank is designed with a full consideration of the spectrum characteristics of voltage fluctuation signals described as AM. The frequency and magnitude of the detected flicker signals are estimated using recursive method. Computer simulations were performed on synthesized signals to prove validity of the proposed method.

Active and Reactive Power Control of ESS in Distribution System for Improvement of Power Smoothing Control

  • Shin, Seong-Su;Oh, Joon-Seok;Jang, Su-Hyeong;Cha, Jae-Hun;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1007-1015
    • /
    • 2017
  • This paper proposes a new control technique of energy storage system (ESS) for smoothing the active power of renewable energy sources (RES) such as photovoltaic and wind turbine generation. As the penetration of RES into grid increases, it is difficult to maintain the permissible level of power quality, that is, voltage and frequency fluctuation in power systems. To solve this problem, ESS control methods using low pass filter (LPF) have been proposed for mitigating the fluctuation of RES output. However, those have a lot of drawbacks which need to be supplemented. Hence, this paper presents the improved active power control with additional reactive power control for maintaining power quality properly. The proposed method minimizes the capacity of ESS to be required for smoothing RES output fluctuation through mitigation of phase delay problem in LPF. In addition, the voltage regulation improves by using additional reactive power control. The proposed method was verified through simulation analysis using PSCAD/EMTDC.

대전원타락사고시의 계통동요특성 해석 (Study On The Characteristic Of System Fluctuation Under Large Generator Unit Outage)

  • 송길영;이종훈;김영창
    • 전기의세계
    • /
    • 제24권2호
    • /
    • pp.71-77
    • /
    • 1975
  • This paper describes the results of a study for the stability of power system when the Kori Nuclear #1 P/P is operated with existing system. First, a transient disturbance, which effects the stability of entire power system, was analysed and to cope with the problem a load shedding method was studied to recover the fluctuation of the power system. Second, transient stability problem was studied when three phase fault occurs in 345 Extra High Voltage power System, and from this result, it was found to be highly effective that high speed protecting device should be provided and operated to recover the fault.

  • PDF

해상풍력단지 J-Tube 내부 해저케이블의 절연 특성 평가 (Insulation Characteristics Evaluation of Submarine Cables Inside the J-Tube of Offshore Wind Farms)

  • 이승원;최진욱;김해종
    • 한국전기전자재료학회논문지
    • /
    • 제36권6호
    • /
    • pp.570-575
    • /
    • 2023
  • Demand and necessity for eco-friendly offshore wind farms have been increasing. Research on submarine cables is constantly being considered for a reliable and stable power transmission. This study aimed to evaluate the thermal aging characteristic of submarine cables inside the J-tube of offshore wind farms. In this study, a submarine cable was set in three sections: The first is the part exposed to the air above the sea level at high temperature. The second is the section exposed to repeated temperature fluctuation as the sea level rises and falls. The third is the part submerged at low temperature below the sea level. Aged samples were tested by using the method of electrical evaluation to obtain insulation characteristics. The experimental results show that the dielectric breakdown of the sample with temperature fluctuation was 7% lower than the sample with a constant temperature; thereby, demonstrating that the section where the temperature fluctuation occurred in the submarine cables was weaker than the other. The sections of submarine cable with temperature fluctuations are believed as a weak point during operation; therefore, this part should be monitored preferentially.

The Numerical Simulation of Unsteady Flow in a Mixed flow Pump Guide Vane

  • Li, Yi-Bin;Li, Ren-Nian;Wang, Xiu-Yong
    • International Journal of Fluid Machinery and Systems
    • /
    • 제6권4호
    • /
    • pp.200-205
    • /
    • 2013
  • In order to investigate the characteristics of unsteady flow in a mixed flow pump guide vane under the small flow conditions, several indicator points in a mixed flow pump guide vane was set, the three-dimensional unsteady turbulence numerical value of the mixed flow pump which is in the whole flow field will be calculated by means of the large eddy simulation (LES), sub-grid scale model and sliding mesh technology. The experimental results suggest that the large eddy simulation can estimate the positive slope characteristic of head & capacity curve. And the calculation results show that the pressure fluctuation coefficients of the middle section in guide vane inlet will decrease firstly and then increase. In guide vane outlet, the pressure fluctuation coefficients of section will be approximately axially symmetrical distribution. The pressure fluctuation minimum of section in guide vane inlet is above the middle location of the guide vane suction surface, and the pressure fluctuation minimum of section in which located the middle and outlet of guide vane. When it is under the small flow operating condition, the eddy scale of guide vane is larger, and the pressure fluctuation of the channel in guide vane being cyclical fluctuations obviously which leads to the area of eddy expanding to the whole channel from the suction side. The middle of the guide vane suction surface of the minimum amplitude pressure fluctuation to which the vortex core of eddy scale whose direction of fluid's rotation is the same to impeller in the guide vane adhere.

개선된 가변속 풍력발전기의 주파수 평활화 (Improved Frequency Mitigation of a Variable-Speed Wind Turbine)

  • ;;강용철;홍준희
    • 전기학회논문지
    • /
    • 제67권6호
    • /
    • pp.695-701
    • /
    • 2018
  • For a power grid that has a high wind penetration level, when wind speeds are continuously fluctuating, the maximum power point tracking (MPPT) operation of a variable-speed wind turbine (VSWT) causes the significant output power fluctuation of a VSWT, thereby significantly fluctuating the system frequency. In this paper, an improved power-smoothing scheme of a VSWT is presented that significantly mitigates the frequency fluctuation caused by varying wind speeds. The proposed scheme employs an additional control loop based on the frequency deviation that operates in combination with the MPPT control loop. To improve the power-smoothing capability of a VSWT in the over-frequency section (OFS), the control gain of the additional loop, which is set to be inversely proportional to the rotor speed, is proposed. In contrast, the control gain in the under-frequency section is set to be proportional to the rotor speed to improve the power-smoothing capability while avoiding over-deceleration of the rotor speed of a VSWT. The proposed scheme significantly improves the performance of the power-smoothing capability in the OFS, thereby smoothing the frequency fluctuation. The results clearly demonstrate that the proposed scheme significantly mitigates the frequency fluctuation by employing the different control gain for the OFS under various wind penetration scenarios.