Standby Strategies for Energy Saving in Peripheral Equipment of Machine Tools (공작기계 주변장치의 에너지 절감 대기전략)

  • Kim, Taejung;Kim, Taeho;Jee, Sungchul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.5
    • /
    • pp.486-492
    • /
    • 2013
  • Energy cost has been increasing rapidly to comply with environmental regulations worldwide and the manufacturing industry who consumes more than half of the total energy needs to improve their cost competitiveness considering environmental costs. Machine tools are essential elements in manufacturing industry and efforts have been made recently to increase their energy efficiency mainly by German and Japanese machine tool builders. In this paper, trends in energy saving technology are described on the hardware and software sides of peripheral equipment of machine tools. In addition, the power consumption of a machining center is measured and analyzed to develop a software-based standby strategy for energy saving with peripheral equipment of machine tools.

The Effect Analysis in case of the Countermeasure and Trouble-Examples for the Noise of Control Equipment System (제어설비 계통에서의 노이즈장해 사례 및 대책별 효과 분석)

  • Kim, Hong-Ju;Yoo, Sang-Bong;Lee, Ho-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.75-81
    • /
    • 2005
  • Recently an increase of sensor and power trandusers in control equipment system has caused many kinds of noise the mis-operation equipment and demage program memories of control circuits. In this paper, the noise character of the various control equipment system has been measured and analyzed. Additionally, the countermeasure to reduce noise like as Noise Cut Transformer, Equipotential Bonding, Power Noise Rejector, Noise Filter has been applied and confirmed the effective results to solve the trouble of noise.

Preventive Maintenance Plan of Power System Unit Considering Imperfect Maintenance (불안전한 유지보수를 고려한 전력 설비의 예방 정비 계획)

  • Byeon, Yoong-Tae;Kim, Hyung-Jun;Kim, Jin-O;Kim, Hyung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.328-330
    • /
    • 2007
  • Recently, the research of PM (Preventive Maintenance) method on the RCM(Reliability-Centered Maintenance) of the system equipment is being actively advanced for a few years. The state of the power equipment is maintained like the states of the between 'as good as new ones' and 'as bad as old ones' by imperfect Maintenance that implies the life decrease of the equipment by frequent breakdown, the error of maintenance process, and so on. So, the Maintenance method considering the real case has to reflect Imperfect maintenance than perfect maintenance. This paper suggests the Preventive Maintenance method by using Quasi - Renewal Theory for the gas turbine equipment as deliberating the imperfect maintenance for the real cases.

  • PDF

A Study on the Countermeasure and Trouble-Examples by Noise in Control Equipment System (제어설비 계통의 노이즈장해 사례 및 대척에 관한 연구)

  • Yoo, Sang-Bong;Kim, Hong-Ju;Lee, Ho-Sung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.325-330
    • /
    • 2005
  • Recently an increase of sensor and power trandusers in control equipment system has caused many kinds of noise. These kinds of noise came out the mis-operation equipment and demage program memories of control circuits. In this paper, the noise generation of control equipment system han been measured and analyzed. Additionally, the effective protection equipments to reduce noise like as Noise Cut Transformer, Equipotential Bonding, Power Noise Rejector, Noise Filter has been applied and proposed the measured results.

  • PDF

Optimal Maintenance Interval Decision For Minimum Cost (최소 비용을 위한 최적의 유지보수 주기 결정)

  • Kim, Hyung-Jun;Shin, Jun-Seok;Kim, Jin-O;Kim, Hyung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.742-743
    • /
    • 2007
  • A maintenance plan of power system equipment reduces failure rate caused by equipment's age. To prevent unexpected failure, the maintenance is performed periodically according to the interval time. The more expansive equipment's scale is, the more the maintenance without considering costs sustains a economical loss. Hence, the maintenance's time and the cost must be considered when maintenance which is considering the reliability is implemented. In this paper, optimum maintenance interval is calculated by considering minimum maintenance cost of the equipment with the combined cycle units in Korea power systems.

  • PDF

ATWS Frequency Quantification Focusing on Digital I&C Failures

  • Kang Hyun Gook;Jang Seung-Cheol;Lim Ho-Gon
    • Nuclear Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.184-195
    • /
    • 2004
  • The multi-tasking feature of digital I&C equipment could increase risk concentration because the I&C equipment affects the actuation of the safety functions in several ways. Anticipated Transient without Scram (ATWS) is a typical case of safety function failure in nuclear power plants. In a conventional analysis, mechanical failures are treated as the main contributors of the ATWS. This paper quantitatively presents the probability of the ATWS based on a fault tree analysis of a Korea Standard Nuclear Power Plant is also presented. An analysis of the digital equipment in the digital plant protection system. The results show that the digital system severely affects the ATWS frequency. We also present the results of a sensitivity study, which show the effects of the important factors, and discuss the dependency between human operator failure and digital equipment failure.

A basic Study on Establishment Plan of Design Information Traceability through Design Information Flow Identification for Controlled Equipment during the NPP Lifecycle (원전 생애주기 관리대상 기기의 정보 흐름 규명을 통한 설계정보 추적성 구현방안에 대한 기초 연구)

  • Lim, Byung-Ki
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.183-184
    • /
    • 2017
  • Some of the information created during the design phase of an New NPP life cycle is useful only for the execution of the construction phase; however, much of the information greatly impacts the longer-term operational phase. To most make use of design and construction information produced by data based design system during the construction and operation phase, This research is identified controlled data and drawn design information of controlled equipment from documents generated during the life-cycle stages. This study aimed to analyze related documents to assure traceability of controlled equipment from design phase through O&M and then suggested DB(Data Base) based control method on technical information of major equipment throughout nuclear power plant lifecycle.

  • PDF

Design of Economic Analysis Module for Waste Heat Recovery based on Systems Engineering Approach (시스템엔지니어링 기반 산업 폐열 발전시스템 경제성 분석 모듈 설계)

  • Kim, Joon Young;Cha, Jae Min;Park, Sung Ho;Shin, Jung Uk;Lee, Tae Kyong
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.14 no.1
    • /
    • pp.1-12
    • /
    • 2018
  • In the energy-guzzling industries such as steel making and cement, power plants utilizing waste heat have been attracting attention to increase energy efficiency. However, the existing economic analysis system doesn't consider the special working fluids and the cost models of the main equipment used in the waste heat recovery power plant. So it is difficult to estimate the plant economics accurately. Therefore, It is required to develop a economic analysis module that can more accurately evaluate for the power plant. In this study, the systems engineering approach was used to design and develop the module that systematically reflects the characteristics of the power plant and various requirements. Specifically, first, the special working fluids and main equipment applied to the power plant were investigated. Next, the cost models for each equipment were developed. Finally, the economic analysis module based on this was developed.

Research for Implementation of Real-time Power Measurement and Storage System (소규모 전력시스템를 위한 실시간 전원 계측 및 저장 시스템 구현에 관한 연구)

  • Seo, Jong-Wan;Suh, Hee-Seok;Shin, Myong-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.29-36
    • /
    • 2007
  • According to the using of electric power source such as solar cell, fuel cell and wind energy, consumer is supplied from distributed generator and electric power company. Therefore, it is required that the real-time measurement and control instrument for those distributed generator. In this paper, describes the development of measuring equipment for the power system with distributed generator. The equipment has real-time measure function and communication with PC via USB port, which is used for various purposes such as investigation of transient state, and is compared with measurement instrument to verify the reliability.

스마트 그리드에 그린 IT 활용 연구

  • Jeong, Hyeon-Su;Kim, Byeong-Sik;Wang, Mi-Gyeong;Kim, Jong-Hun;Han, Myeong-Ji
    • Proceedings of the Korea Database Society Conference
    • /
    • 2010.06a
    • /
    • pp.33-41
    • /
    • 2010
  • Recently the number of IT equipment have increased. It consumes large amounts of energy and is emissions of greenhouse gases. Co2 emissions with the PC and the monitor has the highest percentage to 39% more than other IT equipment. In addition, Plan for your PC's power management and technology development is being pursued in developed countries. To reduce energy costs of organizations with large numbers of the PC and to cut down on Co2 emissions, the energy load control technology of ACPI standards-based PC IS suggested. AMI-based PC power-management system was constructed, Approximately 20% of operating a result of the test power consumption was reduced. Looking at the case of the United States, PC monitors from the University of Wisconsin-Oshkosh was Sleep mode. As a result, the monitor on a, $ 20 for a year reduced energy costs. In GE(General Electronic), Approximately 75,000 PC's power setting time was Monitor Off :15 minutes/ Hard Drives Off 30 minutes/ System Standby 30 minutes/ Hibernation mode 2 hours. 1 year, electric bill was $ 2.5 million savings and 3 years electric bill was $ 6.5 million savings. Measuring energy usage data, using the measured data, electric energy management technology is not. Platform development to measure energy usage for Individual energy-consuming equipment is urgently required.

  • PDF