• Title/Summary/Keyword: Power Effect

Search Result 10,606, Processing Time 0.033 seconds

Improved Operating Method of Utility Interactive PV System for Peak Power Cut Effect (첨두부하 삭감효과를 갖는 UIPV시스템의 개선된 운용방법)

  • Kim, Young-Sik;Bayasgalan, Dugarjav;Heo, Hye-Seong;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.415-422
    • /
    • 2009
  • This paper describes the UIPV(Utility Interactived Photovoltaic) system which can improve the peak-cut effect by adding energy storage device of batteries to the power converter. The proposed system has three possible operation modes depending on relative condition of PV output, which can have the power shaping function covering the peak power for 3 hours. A new power circuit and application algorithm has been applied to UIPV system which is based on working PV system during 3-hour peak time. The energy relationship by the proposed system is analyzed theoretically and experimentally. Also the proposed system is evaluated at the viewpoint of cost and total spacing, which enables the proposed UIPV system to have the reduction of the peak power demand and hence to improve.

Confinement Effect Analysis Of Suction Pile In Ground Soil On The Basis Of Natural Frequency Measurement (고유진동수 기반 석션기초의 지반구속효과 분석)

  • Ryu, Moo Sung;Lee, Jun Shin;Lee, Jong Hwa;Seo, Yun Ho
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.31-36
    • /
    • 2022
  • This paper presents the measuring process of dynamic properties of offshore wind power foundation and provides consideration of each step. This Guideline enables to maintain consistent measuring procedure and therefore increase the reliability of test results. Small scaled suction bucket foundation was fabricated to represent the commercial support structure installation mechanism and two cases(free-free, free-fixed) of dynamic tests were performed at workshop. From the tests, the importance of dynamic properties of connection part between suction bucket and tower was figured out. More over, types and configuration of measuring devices are recommended which can help find the natural frequency of wind turbine foundation correctly. In field test, it was found that the natural frequency of suction bucket foundation was increased linearly with the penetration depth due to the confining effect of ambient soil. Meanwhile, it was not easy to get an enough excitation force with normal impact hammer because the N.F of suction bucket model was in the lower range of 0 Hz ~ 5 Hz. Therefore, new excitation method which has enough force and can excite lower frequency range was devised. This study will help develop safety check procedure of suction bucket foundation in field at each installation stage using the N.F measurement.

DFT-based Power System Frequency Estimation using Two Digital Filters for Noise Effect Reduction (잡음영향의 저감을 위한 두 디지털 필터들의 사용에 의한 DFT 기반의 계통주파수 추정)

  • Hwang, Jin Kwon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.891-897
    • /
    • 2013
  • The power system frequency plays an important role in monitoring and controlling the power system. The frequency can be measured through discrete Fourier transform (DFT) coefficients of its positive fundamental frequency. The accuracy of the frequency estimate is severely affected by noise in the power system signal and the leakage effect of the negative fundamental frequency in DFT. This paper proposes a DFT-based frequency estimation algorithm to cope with the noise as well as the leakage effect. In this algorithm, two suitable digital filters are introduced to reduce efficiently frequency estimate error due to the noise. These filters are designed to use a digital bandpass filter and a second-degree integrator. The effectiveness of the proposed algorithm in reduction of frequency estimate error is verified through simulations on noise, harmonics and frequency deviation.

Study on the Fluid Film Thickness and Pressure of Elliptical Elastohydrodynamic Lubrication with Spin Effect for the Power Transmitting Contact in the Continuously Variable Transmission (무단 변속기의 동력전달 접촉에서 회전운동을 고려한 타원형상의 점접촉 탄성유체윤활연구)

  • Jang, Si-Youl
    • Tribology and Lubricants
    • /
    • v.21 no.6
    • /
    • pp.272-277
    • /
    • 2005
  • Continuously variable transmission (CVT) of toroidal type has a elliptical shape of contact zone under the elastohydrodynamic lubrication (EHL) condition, where the power is transmitted only by shearing the lubricant. Due to the small contact area of elliptical shape, the traction of the shear behaviors of lubricant over the contact zone is under extremely high contact pressure over 1.0GPa. During the power transmission by shearing the fluid, many kinds of mechanical movements occur such as squeezing, sliding, rolling and spin. Among the movements, the spin effect that is the most undesirable contact behavior in transmitting the power frequently makes significant abnormal wear damage. In this work, the analysis of elliptical contact of EHL with spin effect is performed, which will give very useful information to understand the traction behaviors in toroidal type of CVT system.

A Boundary Protection for Power Distribution Line Based on Equivalent Boundary Effect

  • Zhang, Xin;Mu, Long-Hua
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.262-270
    • /
    • 2013
  • A boundary protection method for power distribution line based on equivalent boundary effect is presented in this paper. In the proposed scheme, the equivalent resonance component with a certain central frequency is sleeve-mounted at the beginning of protected zone. The 'Line Boundary' is built by using boundary effect, which is created by introducing impedance in the primary-side of line. The 'Line Boundary' is significantly different from line wave impedance. Therefore, the boundary protection principle can be applied to power distribution line without line traps. To analyze the frequency characteristic corresponding to traveling-waves of introducing impedance in the primary-side of line, distributed parameters model of equivalent resonance component is established. The results of PSCAD/EMTDC simulation prove the obvious difference of voltage high frequency component between internal faults and external faults due to equivalent resonance component, and validate the scheme.

Look-up Table type Digital Pre-distorter for Linearization Power Amplifier with Non-linearity and Memory Effect (전력증폭기의 비선형 특성과 Memory Effect를 보상하기 위한 Look-up Table 방식의 Digital Pre-distorter)

  • Choi, Hong-Min;Kim, Wang-Rae;Lyu, Jae-Woo;Ahn, Kwang-Eun
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.218-222
    • /
    • 2008
  • RF power amplifier requires linearization in order to reduce adjacent channel interference. And most of the existing linearization algorithms assume that a PA has memory-less nonlinearity. But for the wider bandwidth signal, the memory effect of PA cannot be ignored. This paper investigates digital pre-distortion by use of a memory polynomial model which compensates for amplifier nonlinearity and memory effect. The look-up table based implementation scheme is used to reduce the computational complexity of the pre-distortion block. The linearization performance is demonstrated on wideband CDMA signal and class AB high power amplifier.

  • PDF

Study on short period effect of Marginal Loss Factor(MLF) in Cost Based Pool (CBP시장에서 한계손실계수(MLF)의 적용에 따른 단기적 영향분석)

  • Lee, Jae-Gul;Yoon, Yong-Beum;Ahn, Nam-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.43-45
    • /
    • 2006
  • Because Cost Based Pool(CBP) has any locational signals for electricity price, there are any locational incentives for construction of new power plant high efficient. in case of Korean electricity power market, this incentives are very important to reduce loss and congestion. This Paper represent the effect of MLF(Marginal Loss Factor) as locational price signal in short period. we investigate mathematically loss reduced effect of MLF and prove to reduce transmission loss using 3bus test system.

  • PDF

Research about Competitive Power High Position of Food-Service Industry - Laying Stress on Eating Out Company Interior Factor - (외식기업의 경쟁력 강화 요인에 관한 연구 - 외식기업 내부요인을 중심으로 -)

  • 유택용;박면애
    • Culinary science and hospitality research
    • /
    • v.10 no.3
    • /
    • pp.83-96
    • /
    • 2004
  • According to construction of global administration environment, all over the world was ended up in infinite competition period. Because eating out company also competes with another company, it must enjoy competitive power high position to secure high position continuously, classified by formation constituent's individuation and two aspects of organic special quality by the factor. Individuation classified by formation constituent's business ability, personal relations, age factors of Information Technology, and organic special quality classifies by factor of formation culture and result that analyze eating out company's business condition competitive power reinforcement effect factor is same as following. First, was construed by company culture, personal relations, business ability period of ten days with family Restaurant, and Information Technology showed that do not influence. Competitive power reinforcement effect factor with special restaurant was construed by company culture, personal relations, business ability period of ten days, and fast food company culture and Information Technology factor with hotel restaurant company culture by competitive power reinforcement effect factor construe.

  • PDF

The Effect on Real Power System by the Inrush Current of a Transformer (변압기 돌입전류에 의한 실계통 영향 분석)

  • Shin, Jeong-Hoon;Jang, Gil-Soo;Yoon, Yong-Beum
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.318-321
    • /
    • 1999
  • This paper describes the study of the effect on real power system due to the inclusion of the MTR at Buk Che-ju TP #2. The test system in which the transformers are represented in detail and rest Che-ju systems are represented as an equivalent system on the bus is simulated by the EMTDC. Simulation results include magnitude of inrush current and voltage drop on the bus at various CB closing time, and they show the effect on Che-ju system by the inrush current of the Buk Che-ju TP #2's MTR is not considerable.

  • PDF

The Relationship between Interdependence on Relational Satisfaction in Cosmetics Distribution Channels: Moderating Effect of Communication and Mediating Effect of Non-coercive Power

  • Sun, Il-Suck;Yang, Hoe-Chang
    • The Journal of Economics, Marketing and Management
    • /
    • v.4 no.1
    • /
    • pp.9-22
    • /
    • 2016
  • This study tried to examine how interdependence, communication, and the exercise of power in cosmetics distribution channel would affect satisfaction. In this study we investigated the effects of their communication and the exercise of noncoercive power of department store (or mart). We conducted with managers of the shops which were entered to department store (or mart). 131 copies were collected and 119 copies were used for analysis after the exclusion of 12 copies. Brand image and sales policy influenced satisfaction, but customers were not statistically significant. In addition, communication in distribution path had the moderating effect on the relationship between interdependence and satisfaction, and on the relationship between interdependence and noncoercive power. Sales policy and brand image in the relationship between department store(or mart) and the shops opened inside are critical factors for satisfaction, but customers are highly likely to become a factor with different meaning.