• Title/Summary/Keyword: Power Domain

Search Result 1,335, Processing Time 0.028 seconds

Efficient Power and Rate Adaptation Strategy for Improved Spectral Efficiency in Multi-Carrier DS-CDMA Communications (다중 반송파 부호분할 다중접속 통신에서의 주파수 효율 향상을 위한 효율적인 전력 및 전송률 적응화 기법)

  • Lee, Ye Hoon;Kim, Dong Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.8
    • /
    • pp.697-703
    • /
    • 2013
  • We propose an efficient frequency-time domain resource allocation scheme in multi-carrier (MC) direct-sequence code-division multiple-access (DS/CDMA) communications. We consider, as a power allocation strategy in the frequency domain, transmitting each user's DS waveforms over the user's sub-band with the largest channel gain. We then consider rate adaptation in the time domain, where the data rate is adapted such that a desired transmission quality is maintained. We analyze the achievable average data rate of the proposed scheme with fixed average transmission power, and compare the performance to single carrier DS/CDMA systems with power and rate adaptations.

Islanding Detection for a Micro-Grid based on the Instantaneous Active and Reactive Powers in the Time Domain (시간영역에서 순시 유효/무효전력을 이용한 마이크로그리드의 단독운전 판단)

  • Lee, Young-Gui;Kim, Yeon-Hee;Zheng, Tai-Ying;Kim, Tae-Hyun;Kang, Yong-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.22-27
    • /
    • 2012
  • Correct and fast detection of a micro-grid (MG) islanding is essential to the MG since operation, control and protection of the MG depend on an operating mode i.e., an interconnected mode or an islanding mode. When islanding occurs, the frequency of the point of common coupling (PCC) is not the nominal frequency during the transient state owing to the frequency rise or drop of generators in the MG. Thus, the active and reactive power calculated by the frequency domain based method such as Fourier Transform might contain some errors. This paper proposes an islanding detection algorithm for the MG based on the instantaneous active and reactive powers delivered to the dedicated line in the time domain. During the islanding mode, the instantaneous active and reactive powers delivered to the dedicated line are constants, which depend on the voltage of the PCC and the impedance of the dedicated line. In this paper, the instantaneous active and reactive powers are calculated in the time domain and used to detect islanding. The performance of the proposed algorithm is verified under various scenarios including islanding conditions, fault conditions and load variation using the PSCAD/EMTDC simulator. The results indicate that the algorithm successfully detects islanding for the MG.

Digital Time-Domain Simulation of Ferroresonance of Potential Transformer in the 154 kV GAS Insulated Substation

  • Shim, Eung-Bo;Woo, Jung-Wook;Han, Sang-Ok
    • KIEE International Transactions on Power Engineering
    • /
    • v.11A no.4
    • /
    • pp.9-14
    • /
    • 2001
  • This paper reports a set of digital time-domain simulation studies conducted on 154 kV wound Potential Transformer(PT) int he 154 kV Gas Insulated Substation(GIS). The Electro-Magnetic Transient Program(EMTP) is used to develop the PT model and conduct the transient studies. The accuracy of the PT model is verified through comparison of the EMTP simulation results with those obtained from the field test results. The investigations shows that the developed model can accurately predict PT transient resonance, especially, the phenomenon of ferroresonance. The model is developed not only to determine impact of transients on PT response but also to design ferroresonance suppressor devices of PT. And it can also be used to predict PT transient response on power system monitoring and protection scheme.

  • PDF

Reliability Test of Power System Stabilizer for Samchunpo Thermal Power Plant (삼천포 화력 계통 안정화 장치 건전성 평가에 관한 연구)

  • Kim, Bong-Suck;Ryu, Ho-Seon;Lim, Ik-Hun
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.497-499
    • /
    • 2007
  • 전력연구원은 한국남동발전(주) 삼천포화력 발전소의 요청에 따라 삼천포 화력 6호기 계획예방정비공사 기간(07.03.14-04.19) 중 발전기 여자시스템의 계통안정화 장치의 시간영역(Time Domain)과 주파수영역(Frequency Domain)에서의 Step 시험을 통하여 건전성을 평가하였다. 본 논문에서는 전력계통의 동요를 안정시키기 위한 삼천포 화력 발전기 여자시스템의 계통 안정화 장치(GE사 3S7932LA300)의 개요, 구성 및 건전성 평가 결과를 기술하였다.

  • PDF

Maximal overlap discrete wavelet transform-based power trace alignment algorithm against random delay countermeasure

  • Paramasivam, Saravanan;PL, Srividhyaa Alamelu;Sathyamoorthi, Prashanth
    • ETRI Journal
    • /
    • v.44 no.3
    • /
    • pp.512-523
    • /
    • 2022
  • Random delay countermeasures introduce random delays into the execution flow to break the synchronization and increase the complexity of the side channel attack. A novel method for attacking devices with random delay countermeasures has been proposed by using a maximal overlap discrete wavelet transform (MODWT)-based power trace alignment algorithm. Firstly, the random delay in the power traces is sensitized using MODWT to the captured power traces. Secondly, it is detected using the proposed random delay detection algorithm. Thirdly, random delays are removed by circular shifting in the wavelet domain, and finally, the power analysis attack is successfully mounted in the wavelet domain. Experimental validation of the proposed method with the National Institute of Standards and Technology certified Advanced Encryption Standard-128 cryptographic algorithm and the SAKURA-G platform showed a 7.5× reduction in measurements to disclosure and a 3.14× improvement in maximum correlation value when compared with similar works in the literature.

Design of SC-FDE System Using CAZAC Sequence (CAZAC Sequence를 이용한 SC-FDE 시스템 설계)

  • Kang, Hoon;Im, Se-Bin;Choi, Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.2A
    • /
    • pp.169-178
    • /
    • 2007
  • In this paper, we propose a signal structure and its optimum receiver to improve performance of SC-FDE(Single Carrier with Frequency Domain Equalization) system. Conventional SC-FDE systems have a drawback of power unbalance in frequency domain due to generation of pilot signals in time domain. The unbalanced power in frequency domain induces a channel estimation error and the performance of the receiver is degraded significantly. To overcome the drawback we apply CAZAC sequence which has constant power distribution in time and frequency domain. We design the signal structure to improve the performance with the repeated CAZAC sequence, and we design a receiver to optimize the proposed structure. Computer simulation results show that the proposed structure is superior to the conventional structure considering frame synchronization, frequency synchronization and channel equalization on typical wireless mobile channel environment.

The influence of phentermine hydrochloride on heart rate variability (비만 치료제 Phentermine Hydrochloride가 심박동 변이율(Heart Rate Variability)에 미치는 영향)

  • Gang, Hui-Cheol
    • Journal of Korea Association of Health Promotion
    • /
    • v.4 no.1
    • /
    • pp.28-38
    • /
    • 2006
  • Background : Phentermine classified by "sympathomimmetic amie", is a stimulant of sympatheic tone But there has been no concrete study which presents the influence of phentermine on autonomic nervous system. Analysis of Heart rate variability is reliable, non-invasive and very useful for evaluating function of autonomic nervous system. We tried to elucidate the influence of phentermine on autonomic nervovs system by heart rate variability. MethodsAmong the 70 candidates who participated in the double-blind case control study whichwas designed in purpose of approving whether- Adipekⓓ is effective for treatment of obesity, 45persons were folled up. From April, 2005 to May 2005, HRV of the candidates who takes phentermine or placebo for 1month, was recorded using BFM-5000ⓓ(medi-core) for 5 minutes in resting state. HRV measures were assessed by time-domain and by frequency- domain analysis. Time domain parameters contain SDNN(Standard Deviation of NN intervals) and RMSSD(Root-Mean-Square of Successive Differences), etc and frequency domain Parameters contain Total Power(TP), Low frequency(LF'0.04-0.15Hz) power. High Frequency(HF:0.15-0.4Hz) power and LF/HF ratio etc. Results: Intakes of phentermine reduce HRV significant1y. SDNN & RMSSD, the main tine domain parameters of HRV, were decreased significantly(P=0.007. 0.016). PSI(Physical Stress Index of Pressure Index) was increase significantly(P=0.002)The main frequency domain parameters(TP, LF & VLF), also decreased significantly. (P=0.024,0.033, 0.015)Conclusion: The result showed that intakes of phentermine reduce heart rate variability and influence on most parameters of HRV. So phentermine not only accelerates sympathetic tone, but also inhibit the balance and function of autonomic nervous system.

  • PDF

Power Allocation and Capacity Analysis of OFDM-based Unlicensed User in TV White Space (TV 화이트 스페이스에서 OFDM 기반 비인가 사용자의 파워 할당 기법 및 용량 분석)

  • Lim, Sung-Mook;Hong, Dae-Sik
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.8
    • /
    • pp.70-76
    • /
    • 2012
  • In this paper, we propose a power allocation scheme of the unlicensed user based on orthogonal frequency division multiplexing (OFDM) in the TV white space (TVWS). Power constraints in TVWS should be satisfied in the time domain. However, because OFDM has high PAPR (peak-to-average power ratio), it is difficult to satisfy power constraints of TVWS in the time domain. Furthermore, the conventional power allocation schemes cannot be generally applied to unlicensed user in TVWS. Therefore, we propose a power allocation scheme to satisfy power constraints of TVWS by reducing PAPR in the time domain. In addition, we analyze the capacity of the unlicensed user based on OFDM in a closed form. Based on the capacity analysis, as the number of subcarriers decreases, the capacity can be enhanced. In simulation results, we show that the capacity of the unlicensed user increases, as the number of subcarriers decreases and the mean of the channel between the transmitter and the receiver of the unlicensed user increases.

The Effects of Moxibustion on Heart Rate Variability in Cancer Patients (쑥뜸치료가 암환자의 심박변이도에 미치는 영향)

  • Kim, Ok-Hee;Choi, Jung-Eun;Yoon, Jeung-Won;Yoo, Hwa-Seung
    • Journal of Korean Traditional Oncology
    • /
    • v.16 no.1
    • /
    • pp.15-31
    • /
    • 2011
  • Objective : The study aims to investigate the effect of moxibustion treatments on autonomic nervous system function of cancer patients through the evaluation of heart rate variability (HRV) biofeedback testing. Materials and Methods : Six cancer patients from inpatient care unit of Dunsan Oriental Hospital, Daejeon University were given three moxibustion treatment sessions every other day over one week period on five Oriental Medicine meridian points CV4, CV6, CV12, KD1, and PC8. HRV biofeedback was conducted before and after each treatment sessions. Three areas of analyses were done from the test conducted; Time Domain Analysis, Frequency Domain Analysis and Autonomic Nervous System (ANS) balance analysis. Results : Time Domain Analysis has shown increased Standard Deviation of all Normal R-R Intervals (SDNN), and decreased Mean Heart Rate and Physical Stress Index (PSI) levels, with statistical significance (P<0.05). In Frequency Domain Analysis, series of moxa treatments have increased Total Power (TP), Very Low Frequency Oscillation Power (VLF), High Frequency Oscillation Power (HF), normalized HF values while decreasing Low Frequency Oscillation Power (LF), normalized LF and LF/HF ratio with statistical significance (P<0.05). The values of ANS activity, ANS balance, Stress resistance, Stress index, have also shown significant changes. For cardiac stability stroke volume power (SP) and Blood Vessel Tension (BVT) were followed, which were both increased after treatment. All changes were statistically significant (P<0.05). Conclusion : The results have shown a positive correlation between the moxibustion treatments and autonomic nervous system responses on cancer patients through the HRV biofeedback testing. This study suggests possible application of moxibustion treatments for managing ANS functions of cancer patients, although additional studies with larger population are necessary to confirm the data.

Power Quality Disturbances Detection and Classification using Fast Fourier Transform and Deep Neural Network (고속 푸리에 변환 및 심층 신경망을 사용한 전력 품질 외란 감지 및 분류)

  • Senfeng Cen;Chang-Gyoon Lim
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.1
    • /
    • pp.115-126
    • /
    • 2023
  • Due to the fluctuating random and periodical nature of renewable energy generation power quality disturbances occurred more frequently in power generation transformation transmission and distribution. Various power quality disturbances may lead to equipment damage or even power outages. Therefore it is essential to detect and classify different power quality disturbances in real time automatically. The traditional PQD identification method consists of three steps: feature extraction feature selection and classification. However, the handcrafted features are imprecise in the feature selection stage, resulting in low classification accuracy. This paper proposes a deep neural architecture based on Convolution Neural Network and Long Short Term Memory combining the time and frequency domain features to recognize 16 types of Power Quality signals. The frequency-domain data were obtained from the Fast Fourier Transform which could efficiently extract the frequency-domain features. The performance in synthetic data and real 6kV power system data indicate that our proposed method generalizes well compared with other deep learning methods.