POWER SERIES RINGS OVER PRÜFER v-MULTIPLICATION DOMAINS

  • Chang, Gyu Whan
    • 대한수학회지
    • /
    • 제53권2호
    • /
    • pp.447-459
    • /
    • 2016
  • Let D be an integral domain, {$X_{\alpha}$} be a nonempty set of indeterminates over D, and $D{\mathbb{[}}\{X_{\alpha}\}{\mathbb{]}_1}$ be the first type power series ring over D. We show that if D is a t-SFT $Pr{\ddot{u}}fer$ v-multiplication domain, then $D{\mathbb{[}}\{X_{\alpha}\}{\mathbb{]}}_{1_{D-\{0\}}}$ is a Krull domain, and $D{\mathbb{[}}\{X_{\alpha}\}{\mathbb{]}}_1$ is a $Pr{\ddot{u}}fer$ v-multiplication domain if and only if D is a Krull domain.

저전압, 저전력 BiCMOS 로그 도메인 필터 설계 (Design of BiCMOS Log-Domain Filters for Low-Voltage and Low-Power)

  • 안나영;우영신;성만영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1605-1607
    • /
    • 2000
  • In this paper, the design of class AB BiCMOS log-domain filter for low-voltage and low-power was proposed. This filter is consist of a log-domain integrator using folded junctions with capacitor connected to emitter and it's class AB structure. A comparison between the proposed class AB BiCMOS log-domain filter and classical class A BiCMOS log-domain filter is drawn on the basis of SNR, THD and the frequency response. This comparison shows proposed filter are more than good SNR, THD and frequency characteristics than more class A log-domain filter for low voltage and low power.

  • PDF

레일레이 패이딩 채널에서 다중 반송자 DS/CDMA 통신 시스템의 전력-전송율 적응 방식 (Power and Rate Adaptations in Multi-carrier DS/CDMA Communications over Rayleigh Fading Channel)

  • 안희준;이예훈
    • 한국통신학회논문지
    • /
    • 제30권6C호
    • /
    • pp.423-433
    • /
    • 2005
  • 다중 반송자를 사용하는 CDMA 통신 시스템에서 주파수 영역의 전력과 시간 영역의 전송율을 적응적으로 사용하는 시스템을 분석하였다. 수신단으로 부터 얻는 이상적인 채널상태 정보를 가정하고, 주파수 영역에서는 각 사용자의 부채널 중에서 가장 채널상태가 좋은 한 대역을 선택하고, 시간영역에서는 목표 수신 품질을 만족하도록 전송율을 조정한다. 단일 사용자의 경우에 평균 BER을 최소화 할 수 있는 최적의 전송 방식의 식을 유도하였다. 채널 상태 역수 법이 사용 대역의 수나, 평균 전송양이 증가할 때 최적의 알고리듬이라는 사실 또한 증명하였다. 수학적 분석과 시뮬레이션 결과 제안된 주파수 시간 적응 알고리듬을 사용한 방식이 주파수영역에서만 선택적인 방법을 사용하는 MC-CDMA 방식과 비교하여 현격히 좋은 성능을 보임을 보였다. 또한 제안된 적응형 MC-CDMA 전송방식과 기존의 RAKE 수신기를 사용하고 시간 영역에서 적응적 방식을 사용하는 DS-CDMA 시스템과 성능을 비교하였다.

상호작용 중요도 행렬을 이용한 단백질-단백질 상호작용 예측 (Protein-Protein Interaction Prediction using Interaction Significance Matrix)

  • 장우혁;정석훈;정휘성;현보라;한동수
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제36권10호
    • /
    • pp.851-860
    • /
    • 2009
  • 최근 계산을 통한 단백질 상호작용 예측 기법 중, 단백질 쌍이 포함하고 있는 도메인들 사이의 관계에 중점을 둔 도메인 정보 기반 예측 기법들이 다양하게 제안되고 있다. 하지만, 다수의 도메인 쌍들이 상호작용에 기여하는 정도를 정밀하게 반영하는 계산 기법은 드문 실정이다. 본 논문에서는 단백질 상호작용에 있어 도메인 조합 쌍의 상호작용 영향력을 수치화하여 반영한 상호작용 중요도 행렬을 고안하고 이를 기반으로 한 단백질 상호작용 예측 시스템을 구현한다. 일반적인 도메인 조합 기법과 달리, 상호작용 중요도 행렬에서는 상호작용을 위한 도메인간의 협업 확률이 고려된 Weighted 도메인 조합과, 다수의 Weighted 도메인 조합 중 실제 상호작용 주체가 될 확률을 도메인 조합 쌍의 힘(Domain Combination Pair Power, DCPPW)으로 수치화한다. DIP과 IntAct에서 얻어온 S. cerevisiae의 단백질 상호작용 데이터와 Pfam-A 도메인 정보를 사용한 정확도 검증 결과, 평균 63%의 민감도와 94%의 특이도를 확인하였으며, 학습집단의 증가에 따른 안정적인 예측 정확도 향상을 보였다. 본 논문에서 구현한 예측 시스템과 학습 데이터는 웹(http://code.google.com/p/prespi)을 통하여 내려 받을 수 있다.

분포정수계 유압관로 모델의 동특성 해석 (Analysis of Dynamic Characteristics of Hydraulic Transmission Lines with Distributed Parameter Model)

  • 김도태
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권4호
    • /
    • pp.67-73
    • /
    • 2018
  • The paper deals with an approach to time domain simulation for closed end at the downstream of pipe, hydraulic lines terminating into a tank and series lines with change of cross sectional area. Time domain simulation of a fluid power systems containing hydraulic lines is very complex and difficult if the transfer functions consist of hyperbolic Bessel functions which is the case for the distributed parameter dissipative model. In this paper, the magnitudes and phases of the complex transfer functions of hydraulic lines are calculated, and the MATLAB Toolbox is used to formulate a rational polynomial approximation for these transfer functions in the frequency domain. The approximated transfer functions are accurate over a designated frequency range, and used to analyze the time domain response. This approach is usefully to simulate fluid power systems with hydraulic lines without to approximate the frequency dependent viscous friction.

절연전선 결함 위치 추정에 대한 시간-주파수 영역 반사파 계측법의 적용 (Estimation of Fault Location on a Power Line using the Time-Frequency Domain Reflectometry)

  • 두승호;곽기석;박진배
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.268-275
    • /
    • 2008
  • In this paper, we introduce a new method for detecting and estimating faults on a power line using the time-frequency domain reflectometry system. The system rests upon time-frequency signal analysis and uses a chirp signal which is multiplied by Gaussian envelope. The chirp signal is used as a reference signal, and we can get the reflected signal from a fault on a wire. To detect and estimate faults, we analyze the reflected signal by Wigner time-frequency distribution function and normalized time-frequency cross correlation function. In this paper we design an optimal reference signal for power line and implement a system for estimating fault distance on a power line with the TFDR implemented by PXI equipments. This approach is verified by some experiments with HIV 2.25mm power lines.

Decoupling of the Secondary Saliencies in Sensorless PMSM Drives using Repetitive Control in the Angle Domain

  • Wu, Chun;Chen, Zhe;Qi, Rong;Kennel, Ralph
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1375-1386
    • /
    • 2016
  • To decouple the secondary saliencies in sensorless permanent magnet synchronous machine (PMSM) drives, a repetitive control (RC) in the angle domain is proposed. In this paper, the inductance model of a concentrated windings surface-mounted PMSM (cwSPMSM) with strong secondary saliencies is developed. Due to the secondary saliencies, the estimated position contains harmonic disturbances that are periodic relative to the angular position. Through a transformation from the time domain to the angle domain, these varying frequency disturbances can be treated as constant periodic disturbances. The proposed angle-domain RC is plugged into an existing phase-locked loop (PLL) and utilizes the error of the PLL to generate signals to suppress these periodic disturbances. A stability analysis and parameter design guidelines of the RC are addressed in detail. Finally, the proposed method is carried out on a cwSPMSM drive test-bench. The effectiveness and accuracy are verified by experimental results.

Digital Control Strategy for Single-phase Voltage-Doubler Boost Rectifiers

  • Cho, Young-Hoon;Mok, Hyung-Soo;Ji, Jun-Keun;Lai, Jih-Sheng
    • Journal of Power Electronics
    • /
    • 제12권4호
    • /
    • pp.623-631
    • /
    • 2012
  • In this paper, a digital controller design procedure is presented for single-phase voltage-doubler boost rectifiers (VDBR). The model derivation of the single-phase VDBR is performed in the s-domain. After that the simplified equivalent z-domain models are derived. These z-domain models are utilized to design the input current and the output dc-link voltage controllers. For the controller design in the z-domain, the traditional K-factor method is modified by considering the nature of the digital controller. The frequency pre-warping and anti-windup techniques are adapted for the controller design. By using the proposed method, the phase margin and the control bandwidth are accurately achieved as required by controller designers in a practical frequency range. The proposed method is applied to a 2.5 kVA single-phase VDBR for Uninterruptible Power Supply (UPS) applications. From the simulation and the experimental results, the effectiveness of the proposed design method has been verified.

연속 시적분 (CTI) 기반 풍력발전단지 시모의 해석 (Continuation Time Integration (CTI)-Based Time Domain Simulation Analysis for Wind Farms)

  • 조성구;송화창;이장호
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.1971-1979
    • /
    • 2010
  • As a result of increasing environmental concern, the penetration of renewable power on power systems is now increasing. Wind energy can be considered as the most economical energy sources to generate electricity without depletion of fossil fuel. To devise adequate control strategies for wind farm, time domain simulation analysis needs to be performed. This presents a continuation time integration (CTI)-based time domain simulation algorithm for wind farm with doubly fed asynchronous generator (DFAG) connected to the external power systems. This paper depicts how to time trajectories are traced using CTI-based time domain simulation. Also this paper describes the possibilities of hierachical control for wind farm output limitation, and the coordinated control has been designed by hierarchical control structured from central control level to wind farm control board and to an individual wind turbine level. Finally it shows an illustrative example of time domain simulation result with two test systems through case study.