• 제목/요약/키워드: Power Detection System

검색결과 1,402건 처리시간 0.039초

확률적인 소실점 추정 기법에 기반한 강인한 송전선 검출 방법 (A Robust Power Transmission Lines Detection Method Based on Probabilistic Estimation of Vanishing Point)

  • 유주한;김동환;이석;박성기
    • 로봇학회논문지
    • /
    • 제10권1호
    • /
    • pp.9-15
    • /
    • 2015
  • We present a robust power transmission lines detection method based on vanishing point estimation. Vanishing point estimation can be helpful to detect power transmission lines because parallel lines converge on the vanishing point in a projected 2D image. However, it is not easy to estimate the vanishing point correctly in an image with complex background. Thus, we first propose a vanishing point estimation method on power transmission lines by using a probabilistic voting procedure based on intersection points of line segments. In images obtained by our system, power transmission lines are located in a fan-shaped area centered on this estimated vanishing point, and therefore we select the line segments that converge to the estimated vanishing point as candidate line segments for power transmission lines only in this fan-shaped area. Finally, we detect the power transmission lines from these candidate line segments. Experimental results show that the proposed method is robust to noise and efficient to detect power transmission lines.

음향방출을 이용한 보일러튜브 누설평가 (Leak Detection and Evaluation for Power Plant Boiler Tubes Using Acoustic Emission)

  • 이상국
    • 비파괴검사학회지
    • /
    • 제24권1호
    • /
    • pp.45-51
    • /
    • 2004
  • 발전소 보일러튜브는 장시간 동안 고온고압하의 기혹한 조건으로 운전됨에 따라 크리프, 열피로와 같은 각종 열화에 의해 누설손상이 발생하고 있다. 이러한 누설손상을 실시간 감시하고 진단하기 위하여 음향방출기술을 이용한 현장적용 연구를 수행하였다. 또한 고장예측 진단기술, 튜브의 수명관리 및 설비 감시에 활용할 수 있도록 음향방출 진단시스템을 개발하여 현장에 설치하고, 보일러 운전상태에 따른 신호측정 및 평가, 누설위치 판별 등에 대해 고찰하였다. 누설감지는 저주파 및 고주파대역의 누설로 구분하여 음향방출신호를 각각 측정 및 평가하였다. 현장적용 연구결과로부터 실시간으로 보일러튜브 상태감시와 누설위치 추적이 가능하였으며, 향후 본 기술을 이용하면 발전설비 안전운전과 발전소 정지에 따른 경제적 손실 예방에 크게 기여할 것으로 기대된다.

전기자동차용 전력변환시스템의 스위치 개방형 고장 검출 (Switch Open Circuit Fault Detection for Power Conversion System of Hybrid Electric Vehicles)

  • 박태식
    • 전력전자학회논문지
    • /
    • 제18권2호
    • /
    • pp.199-204
    • /
    • 2013
  • Recently, the demand for fuel efficient electric vehicles (EVs) and hybrid electric vehicles (HEVs) has been growing globally. Due to the increased number of switching devices in the electrified vehicles, the probability of the semiconductor device failure is much higher than in other application areas. A sudden failure in one of the power switches and insufficient power management ability in the systems not only decreases system performance, but also leads to critical safety problems. In this paper, novel switch open circuit fault detection method is proposed, and the proposed approach is verified by experiments.

Islanding Detection for PV System Connected to a Utility Grid

  • Han, Seok-Woo;Mok, Hyung-Soo;Choe, Gyu-Ha
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.719-723
    • /
    • 1998
  • Prevention of the islanding phenomena is one of the most important issues because it can damage electrical equipment connected to the utility system and endanger human life. It is very difficult to detect an islanding condition of a power distribution line with conventional voltage of frequency relays, while the output power and the load power of utility interactive PV inverter units are in nearly balanced state in both active power and reactive power. This paper describes the protective equipment that prevents the PV system connected to the utility grid from starting islanding. Both predictive ocntrol method and harmonic injection method are used for a current control and islanding detection for operating safety.

  • PDF

무절연구간을 위한 열차위치검지방식 검토 (A review of the train position detection method for neutral section with energized condition)

  • 이태훈;이시빈;홍현표;이희순;박기범
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1100-1105
    • /
    • 2010
  • The high speed line and conventional line are a single-phase AC feeding system; and power supplies of different phases meet at SS(SubStation)s or SP(Sectioning Post)s. These sections should be negotiated with the main circuit breaker in the traction vehicle switched off, whereby the length of the neutral zone prevents the pantographs shunting adjacent overhead line section. In order for electric railway vehicles to make power running there, there must be a power supply changeover section (approx. for 1km), where a changeover switch changes a power supply to the other power supply of a train running direction sequentially. For a thorough changeover switching control, the precise train position detection is necessarily required. In this paper, to realize the ground-based train position detection method, configuration scheme of train position detection equipment is suggested by using track circuit and axle counter.

  • PDF

Wide-area Frequency-based Tripped Generator Locating Method for Interconnected Power Systems

  • Kook, Kyung-Soo;Liu, Yilu
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권6호
    • /
    • pp.776-785
    • /
    • 2011
  • Since the Internet-based real-time Global Positioning System(GPS) synchronized widearea power system frequency monitoring network (FNET) was proposed in 2001, it has been monitoring the power system frequency in interconnected United States power systems and numerous interesting behaviors have been observed, including frequency excursion propagation. We address the consistency of a frequency excursion detection order of frequency disturbance recorders in FNET in relation to the same generation trip, as well as the ability to recreate by power systems dynamic simulation. We also propose a new method, as an application of FNET measurement, to locate a tripped generator using power systems dynamic simulation and wide-area frequency measurement. The simulation database of all the possible trips of generators in the interconnected power systems is created using the off-line power systems dynamic simulation. When FNET detects a sudden drop in the monitoring frequency, which is most likely due to a generation trip in power systems, the proposed algorithm locates a tripped generator by finding the best matching case of the measured frequency excursion in the simulation database in terms of the frequency drop detection order and the time of monitoring points.

무선 센서네트워크 기반 차량검지 시스템을 위한 저전력 TDMA MAC 프로토콜 (Low-power TDMA MAC protocol for WSN based Vehicle Detection System)

  • 권영진;최진규;김태홍
    • 한국전자통신학회논문지
    • /
    • 제13권5호
    • /
    • pp.1003-1010
    • /
    • 2018
  • 지자기 센서 기반의 차량검지 시스템에서 지자기 센서 노드는 복잡한 케이블 연결 없이 쉽게 도로에 매설할 수 있도록 무선 통신을 이용하는 방식으로 설계되며, 시스템의 유지보수 비용을 줄이기 위해서는 도로에 매설된 지자기 센서 노드의 배터리 수명을 늘리는 것이 중요하다. 본 논문에서는 차량검지 시스템에서의 차량 검지 정보의 실시간성을 보장하면서 지자기 센서 노드의 에너지 소모를 줄일 수 있는 저전력 TDMA 프로토콜을 제안한다. 성능분석에서는 실제 지자기 센서 기반 차량검지 시스템에서의 지자기 센서 노드의 전력 소모를 측정하였으며, 시스템의 시간동기를 유지하면서도 배터리 효율을 62% 향상함으로써 약 5년간 배터리 교체없이 사용할 수 있음을 검증하였다.

Power Quality Early Warning Based on Anomaly Detection

  • Gu, Wei;Bai, Jingjing;Yuan, Xiaodong;Zhang, Shuai;Wang, Yuankai
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1171-1181
    • /
    • 2014
  • Different power quality (PQ) disturbance sources can have major impacts on the power supply grid. This study proposes, for the first time, an early warning approach to identifying PQ problems and providing early warning prompts based on the monitored data of PQ disturbance sources. To establish a steady-state power quality early warning index system, the characteristics of PQ disturbance sources are analyzed and summed up. The higher order statistics anomaly detection (HOSAD) algorithm, based on skewness and kurtosis, and hierarchical power quality early warning flow, were then used to mine limit-exceeding and abnormal data and analyze their severity. Cases studies show that the proposed approach is effective and feasible, and that it is possible to provide timely power quality early warnings for limit-exceeding and abnormal data.

지능형 선박의 효울적인 전력사용을 위한 전력 관리 시스템 개발 (Development of a Power Management System for Efficient Power usage of Intelligent Ship)

  • 박지상;전민호;이명의
    • 한국항행학회논문지
    • /
    • 제17권6호
    • /
    • pp.609-615
    • /
    • 2013
  • 어떤 선박에서도 마찬가지로 적정한 전력의 공급은 매우 중요하며, 육지와 거리가 먼 대양 운항 선박에서는 특히 더욱 중요하다. 이와 같이 운항 중인 선박의 전력 공급 시스템의 효율성과 경제성 측면의 문제를 해결하기 위해서 본 논문에서는 선박에서의 전력공급을 지능적으로 제어하는 전력관리 시스템을 제안한다. 본 설계에서의 전력관리 시스템은 부하전력 감지 시스템, 발전기 제어 시스템, 그리고 전력 모니터링 시스템으로 각각 구성된다. 부하전력 감지 시스템에서는 CT 및 PT 센서를 이용하여 전류와 전력량을 측정하며, 그리고 발전기 제어 시스템에서는 여러 가지 다양한 센서로 부터의 취합정보를 이용하여 주/부 발전기를 On/Off 하게 된다. 마지막으로 모니터링 시스템은 부하 전력 감지 시스템과 발전기 관리 시스템에서 수집된 정보를 사용자가 한눈에 알아볼 수 있게 상태 정보를 출력한다. 본 논문에서 구현된 전력관리 시스템은 실시간 실험을 통해서 설계된 바와 같이 잘 작동하는 것을 확인하였으며, 그리고 공인 인증기관으로부터 KSCIEC61892-1:2012 및 KSCIEC60950-1:2008 인증을 획득하였다.

Slip-Mode Frequency Shift 단독운전 검출 기법의 정상상태 전력 품질 개선 (Design of Modified Slip-Mode Frequency Shift Islanding Detection Method for Power Quality Improvement)

  • 김동욱;김성민
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.539-547
    • /
    • 2018
  • 계통 연계형 인버터는 단독운전 조건에서 반드시 전력 공급을 차단해야 한다. 이러한 이유로 분산 발전 시스템은 단독운전을 검출 기능을 반드시 가지고 있어야 한다. 분산 발전용 인버터에 적용되는 일반적인 방법 중에는 Slip-Mode frequency Shift (SMS) 단독운전 검출 기법이 있다. SMS 기법은 계통 전압의 주파수에 따라 무효 전력을 공급하여 단독운전 조건에서 계통 주파수를 허용 범위 밖으로 이동시키는 방법이다. SMS 기법은 안정적으로 단독운전을 검출할 수 있으며, 계통 전류에 고주파를 인가하지 않는다는 장점이 있으나, 무효 전류를 인가하기 때문에 계통 역률이 나빠져서 전력 품질의 저하를 가져온다. 본 논문에서는 계통 전원이 연결되어 있는 정상 조건에서 전력 품질 저하가 없는 수정된 SMS 기법을 제안한다. 600W 단상 인버터 실험을 통해 제안된 방법의 유효성을 검증한다.