입력전압 파형 검출만으로 구성된 단상 PFC 정류회로 (single-phase PFC rectifier circuit consonant to Input voltage waveform detection)

  • 정상화;이현우;전중함;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.12-15
    • /
    • 2002
  • This propose a simple DC voltage sensor less single phase PFC(Power Factor Correction Circuit) converter by detecting a AC current sensors are not required to construct the control system. The DC voltage is directly controlled by the command input signal Kd($V_o/V_a$)for the boost chopper circuit. The DC voltage regulation is small because of the feed forward control for the AC line voltage VS and no dependence of the circuit parameters. The sinusoidal current waveform in phase with the AC input voltage can be obtained. These characteristics are confirmed by some experiment results.

  • PDF

영구자석 동기전동기 구동용 PWM 전압원 인버터의 실시간 다중 스위치 개방고장 검출 및 고장부 판별기법 (Real-time Multiple Open-switch Fault Detection and Fault Localization for a PWM VSI-fed PMSM Drive System)

  • 송재환;김경화
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.413-414
    • /
    • 2017
  • 영구자석 동기전동기 구동 인버터 시스템 내 스위치 고장은 다양한 조합으로 발생한다. 특히 스위치 개방고장의 경우 다른 전기 부품에 과전류를 유발하여 전체 시스템에 심각한 2차 손상을 초래한다. 본 논문에서는 개방고장 진단 알고리즘의 복잡성을 완화하기 위해 고장 그룹을 분류하여 고장 발생 시 false alarm의 영향을 받지 않고 간단하고 체계적인 방식으로 고장을 식별할 수 있는 기법을 제안한다. 스위치의 개방 고장으로 영구자석 동기전동기 구동 시스템 내 PWM 전압원 인버터의 신뢰성을 향상시키기 위해 3중 스위치 개방고장 진단 및 검출 기법을 제시한다. 제안된 기법은 기존의 개방고장 진단방법과 달리 정보처리를 위해 Moving Filter를 사용함으로써 연산부하를 증가시키지 않고 신속한 고장 검출이 가능하며 별도의 하드웨어 구성없이 구현이 가능하다. 제안된 기법의 안정성과 유효성이 시뮬레이션을 통해 입증된다.

  • PDF

화력발전 설비의 사운드 모니터링 시스템 (Sound Detection System of Machines in Thermal Power Plant.)

  • 이성상;정의필;손창호
    • 융합신호처리학회 학술대회논문집
    • /
    • 한국신호처리시스템학회 2003년도 하계학술대회 논문집
    • /
    • pp.157-160
    • /
    • 2003
  • 발전소에서 운전중인 기계들의 안전운전과 예지 보전을 위하여 발전설비의 고장 감지 및 진단과 상태 모니터링은 중대한 역할을 담당하고 있다. 이 연구에서는 설비의 안전하고 신뢰적인 운전을 위한 기계의 작동상태를 사운드 정보로 획득하고 분석하는 시스템을 제안하였다. 사운드 정보의 사용은 적은 양의 채널의 사용으로 많은 기계 및 설비의 이상 유무의 판별을 가능케 하며, 이를 획득하기 위하여 3개의 마이크로폰, 다채널 A/D변환기, 다채널 I/O Sound Card(Soundtrack DSP24) 및 PC로 시스템을 구성하였다. 소프트웨어 개발언어로서 Microsoft Visual C++ 및 MATLAB을 이용하였다. 화력 발전소에 운전중인 주요기계들의 사운드 정보를 취득하여 취득한 기계별 사운드 정보를 이용하여 주파수 특성을 파악하고, 이를 이용하여 기기의 운전 상태진단을 가능하게 한다.

  • PDF

제어봉구동장치제어기기 전력변환부에 대한 새로운 고장검출 방법 (A New Fault Detection Method fir Power Converter Module in Control Rod Control System)

  • 천종민;김춘경;김석주;이종무;신종렬;권순만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2094-2096
    • /
    • 2003
  • 본 논문에서는 원자력 발전소 제어봉구동장치의 전력변환부에서 발생하는 고장들을 검출하기 위한 새로운 방법을 소개한다. 전력변환부 고장은 제어봉구동장치 동작에 악영향을 미치게 되고 이는 제어봉 오동작으로 이어져 원자로 출력 제어에 차질을 준다. 이러한 이유로 해당 고장의 신속 정확한 검출이 요구된다. 이를 위하여 디지털 시스템 설계용으로 새로운 고장 검출 방법을 도출하고, 기존 웨스팅하우스 모델의 아날로그 맥동 검출기의 약점을 개선하고자 한다.

  • PDF

광섬유 내의 유도 브릴루앙 산란광을 이용한 초고압전력케이블 열화진단에 관한 연구 (A study on the computer diagnosis that apply Neural-Fuzzy algorithm accumulation detection of Partial Discharge signal)

  • 황경준;염경태;김용갑;김진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1558-1559
    • /
    • 2007
  • This study is an application field by using optical fiber. The system to measure sBs from optical fiber is designed, So it can be used as a temperature sensor. by using frequency shift, resulting from temperature changes. the frequency shift is checked by changing temperature from $25^{\circ}C$ to $69^{\circ}C$ with chamber in the laboratory and using 40Km optical fiber. It's also measured by varying the length of optical fiber The program to do the real-time monitoring and analyze the measured data is created to find accurate frequency. It can be used as an optical fiber sensor, which is capable of measuring temperature and distance by using sBs.

  • PDF

Detection of DC-Cable Fault Location for HVDC Transmission Systems Integrated with Wind Farm

  • Nguyen, Thanh Hai;Lee, Dong-Choon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.71-72
    • /
    • 2014
  • This paper presents a method to find the fault location on the DC cables for the HVDC transmission systems which utilizes a hybrid topology of the diode rectifier and the voltage-source converter (VSC) in the wind farm (WF) side. First, the DC-cable fault occurring in this HVDC system is analyzed in detail. Then, the DC-cable fault location is detected from the two relative voltages located on the same section of the cable, which are estimated from a pair of DC-cable voltage and current measurements. The effectiveness of the method is verified by the simulation results.

  • PDF

정밀한 불검출영역 해석을 통한 분산전원 시스템의 새로운 단독운전 방지기법 (A Novel Anti-Islanding Scheme for Distributed Generation System via accurate Analysis of NDZ)

  • 조영민;구본하;최익;송승호;최주엽;이영권;조상윤
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.121-122
    • /
    • 2015
  • 본 논문에서는 기존의 불검출영역(Non Detection Zone; NDZ) 해석보다 수식적으로 더욱 정밀하게 NDZ를 분석한다. 또한, 이런 NDZ를 벗어나게 하는 최소 이득의 Positive-feedback loop를 가지는 새로운 단독운전 방지기법을 설계하고, 이를 시뮬레이션과 실험을 통해 단독운전 검출 성능을 검증하고 제안하는 기법이 전력품질에 끼치는 영향을 분석한다.

  • PDF

대형 건축물과 주거 친화형 저 풍속 연곡형 적층 풍력발전 시스템에 관한 연구 (A Sturdy on the Sleep Twist Round type Stacked Wind Power System for Appling Environment-Friendly Building and High Rise Housing)

  • 정자춘;장미혜
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.796-800
    • /
    • 2011
  • As the increasing integrity of VLSI, the BIST(Built-In Self Test) is used as an effective method to test chips. Generally the pseudo-random test pattern generation is used for BIST. But it requires too many test patterns when there exist random resistant faults. Therefore we propose a mixed test scheme which applies to the circuit under test, a deterministic test sequence followed by a pseudo-random one. This scheme allows the maximum fault coverage detection to be achieved, furthermore the silicon area overhead of the mixed hardware generator can be reduced.

비정상 네트워크 접근 탐지를 위한 전력 시스템 상태 모니터링 설계 (The Design of Monitoring Power System States for Invalid Network Access Detection)

  • 김혁;나중찬
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2012년도 추계학술발표대회
    • /
    • pp.884-887
    • /
    • 2012
  • 전력시스템은 외부 망과 독립적으로 운영되는 폐쇄 망에서 점차 외부 망과의 연계됨으로써 외부 요소에 의한 위협, 다차원적인 시스템 취약성에 노출되고 있다. 서비스 거부 공격은 전력시스템에 매우 치명적이기 때문에 가장 중요한 가용성을 확실히 보장하기 위한 시스템과 네트워크의 운영 및 관리를 통한 보안 대책이 필요하게 되었다. 기존의 네트워크 트래픽만으로 분석하여 이상징후를 탐지하는 방식에 한계가 있기 때문에 본 논문에서는 전력시스템의 네트워크 상태와 엔드 시스템 상태 특성을 실시간 모니터링하고 분석하여 비정상 네트워크 접근을 탐지할 수 있는 시스템을 설계하였다.

오정정 없이 온칩 메모리 보호를 위한 SEC-DED-DAEC 부호 (SEC-DED-DAEC codes without mis-correction for protecting on-chip memories)

  • Jun, Hoyoon
    • 한국정보통신학회논문지
    • /
    • 제26권10호
    • /
    • pp.1559-1562
    • /
    • 2022
  • As electronic devices technology scales down into the deep-submicron to achieve high-density, low power and high performance integrated circuits, multiple bit upsets by soft errors have become a major threat to on-chip memory systems. To address the soft error problem, single error correction, double error detection and double adjacent error correction (SEC-DED-DAEC) codes have been recently proposed. But these codes do not troubleshoot mis-correction problem. We propose the SEC-DED_DAEC code with without mis-correction. The decoder for proposed code is implemented as hardware and verified. The results show that there is no mis-correction in the proposed codes and the decoder can be employed on-chip memory system.