• 제목/요약/키워드: Power Control Error

검색결과 1,081건 처리시간 0.027초

광특성분석시스템(BCS)을 이용한 헬리오스타트 태양추적오차의 측정 및 보정 (Measurement and Compensation of Heliostat Sun Tracking Error Using BCS (Beam Characterization System))

  • 홍유표;박영칠
    • 제어로봇시스템학회논문지
    • /
    • 제18권5호
    • /
    • pp.502-508
    • /
    • 2012
  • Heliostat, as a concentrator to reflect the incident solar energy to the receiver, is the most important system in the tower-type solar thermal power plant since it determines the efficiency and ultimately the overall performance of solar thermal power plant. Thus, a good sun tracking ability as well as a good optical property of it are required. Heliostat sun tracking system uses usually an open loop control system. Thus the sun tracking error caused by heliostat's geometrical error, optical error and computational error cannot be compensated. Recently use of sun tracking error model to compensate the sun tracking error has been proposed, where the error model is obtained from the measured ones. This work is a development of heliostat sun tracking error measurement and compensation method using BCS (Beam Characterization System). We first developed an image processing system to measure the sun tracking error optically. Then the measured error is modeled in linear polynomial form and neural network form trained by the extended Kalman filter respectively. Finally error models are used to compensate the sun tracking error. We also developed the necessary image processing algorithms so that the heliostat optical properties such as maximum heat flux intensity, heat flux distribution and total reflected heat energy could be analyzed. Experimentally obtained data shows that the heliostat sun tracking accuracy could be dramatically improved using either linear polynomial type error model or neural network type error model. Neural network type error model is somewhat better in improving the sun tracking performance. Nevertheless, since the difference between two error models in compensation of sun tracking error is small, a linear error model is preferred in actual implementation due to its simplicity.

Advanced Droop Control Scheme in Multi-terminal DC Transmission Systems

  • Che, Yanbo;Zhou, Jinhuan;Li, Wenxun;Zhu, Jiebei;Hong, Chao
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1060-1068
    • /
    • 2018
  • Droop control schemes have been widely employed in the control strategies for Multi-Terminal Direct Current (MTDC) system for its high reliability. Under the conventional DC voltage-active power droop control, the droop slope applies a proportional relationship between DC voltage error and active power error for power sharing. Due to the existence of DC network impedance and renewable resource fluctuation, there is inevitably a DC voltage deviation from the droop characteristic, which in turn results in inaccurate control of converter's power. To tackle this issue, a piecewise droop control with DC voltage dead band or active power dead band is implemented into controller design. Besides, an advanced droop control scheme with versatile function is proposed, which enables the converter to regulate DC voltage and AC voltage, control active and reactive power, get participated into frequency control, and feed passive network. The effectiveness of the proposed control method has been verified by simulation results.

전류오차 백터 제어방식에 의한 새로운 형태의 전류 제어 PWM 전압형 정류기 (Novel Current Controlled PWM-VSC Converter Using Current Error Vector Control)

  • 박민호;최재호
    • 대한전기학회논문지
    • /
    • 제38권4호
    • /
    • pp.261-268
    • /
    • 1989
  • A novel current controlled PWM voltage source type converter and control strategy is proposed that is able to draw nearly sinusoidal current at unity power factor from three phase power lines. Current error vector control scheme is used which has two operating states : low harmonic current content state and quick current response state. The state is changed according to the current error to optimize the steady state and transient state performances. To regulate the dc oupput voltage, the magnitude of the reference current is determined by a controller dc voltage error. The ac input power factor can be controlled with unity, and even leading or lagging by adjusting the relative position of the reference current with respect to the supply voltage.

  • PDF

전산화된 작업환경에서 인간의 오류성향에 관한 기초연구 (A basic study on human error proneness in computerized work environment)

  • 정광태;이용희
    • 대한인간공학회지
    • /
    • 제19권1호
    • /
    • pp.1-9
    • /
    • 2000
  • This study was performed to investigate some characteristics on human error proneness in the computerized work environment. Our concerning theme was on human error likelihood according to personal temperament. Two experiments were performed. The first experiment was to study the effect of field- independence/dependence on error likelihood. The second experiment was on error proneness. These experiments were performed in information search task. which was most frequent task in computerized work environment such as the control room of nuclear power plant. Ten subjects were participated in this study. Analyzed results are as follows. Field-independence/dependence had a significant effect in both information search time and error frequency. Error proneness had a significant effect in both factors, too. And, a positive correlation was found between error frequency and information search time. These results will be utilized as a basis to study operator's error proneness in the computerized control room of nuclear power plant. later on.

  • PDF

지능형 대용량 비례유량제어밸브 서보컨트롤러 설계 (Design of Intelligent Servocontroller for Proportional Flow Control Solenoid Valve with Large Capacity)

  • 정규홍
    • 유공압시스템학회논문집
    • /
    • 제8권3호
    • /
    • pp.1-7
    • /
    • 2011
  • As the technologies of electronic device have advanced these days, most of mechanical systems are designed with electronic control unit to take advantage of control parameter adaption to operating conditions and firmware flexibilities as well. On-board diagnosis, which detects the system malfunction and identifies potential source of error with its own diagnostic criteria, and fail-safe that can switch the mode of operation in view of recognized error characteristics enables easy maintenance and troubleshooting as well as system protection. This paper dealt with the development of diagnosis and fail-safe function for proportional flow control valve. All type of errors related to valve control system components are investigated and assigned to a specific hexadecimal codes. Cumulative error detection algorithm is applied in order for the sensitivity and reliability to be appropriate. Embedded simulator which runs simultaneously with system program provides the virtual error simulation environment for expeditious development of error detection algorithm. The diagnosis function was verified both with solenoid valve and embedded simulator test and it will enhance the valve control system monitoring function.

Analysis of Estimation Errors in Rotor Position for a Sensorless Control System Using a PMSM

  • Park, Yong-Soon;Sul, Seung-Ki;Ji, Jun-Keun;Park, Young-Jae
    • Journal of Power Electronics
    • /
    • 제12권5호
    • /
    • pp.748-757
    • /
    • 2012
  • In a sensorless control system with a Permanent Magnet Synchronous Motor (PMSM), the angular position of the rotor flux can be estimated by a voltage equation. However, the estimated angle may be inaccurate due to various causes. In this paper, it was comprehensively analyzed how various causes affect the angle error. As a result of the analysis, an error equation intuitively describing these relationships was derived. The parameter errors of a PMSM and the non-ideal properties of the driving system were identified as error-causing factors. To demonstrate the validity of the error equation, PMSMs were tested at various operating points. The variations in angle errors could be well explained with the error equation.

비대칭외란을 고려한 2축 전동실린더의 동기제어에 관한 연구 (A Study on the Synchronous Control of Two Motor Cylinders with Skew Disturbance)

  • 변정환
    • 동력기계공학회지
    • /
    • 제13권6호
    • /
    • pp.129-136
    • /
    • 2009
  • A motor cylinder is widely used as an apparatus for transportation of a small scale load. It is, however, difficult for only one motor cylinder to transfer a large scale load such as a weir. The large scale load is transferred by two motor cylinders which are mounted on right and left of load itself. In this case, the displacement difference generated between two motor cylinders, namely, the synchronous error has a bad influence on the transportation. In this study, a synchronous control system is designed to restrain synchronous error caused by skew disturbance. The control system is composed of two disturbance observers and one synchronous controller. Each disturbance observer is designed to restrain the skew disturbance. And the synchronous controller is designed to achieve stable and accurate synchronization. Finally, the simulation results show that the designed control system is effective for the skew disturbance which lead to synchronous error.

  • PDF

Compensation Technique for Current Sensorless Digital Control of Bridgeless PFC Converter under Critical Conduction Mode

  • Kim, Tae-Hun;Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2310-2318
    • /
    • 2018
  • Critical conduction mode (CRM) operation is more efficient than continuous conduction mode (CCM) operation at low power levels because of the valley switching of switches and elimination of the reverse recovery losses of boost diodes. When using a sensorless digital control method, an error occurs between the actual and the estimated current. Because of the error, it operates as CCM or discontinuous conduction mode (DCM) during CRM operation and also has an adverse effect on THD of input current. In this paper, a current sensorless technique is presented in an inverter system using a bridgeless boosted power factor correction converter, and a compensation method is proposed to reduce CRM calculation error. The validity of the proposed method is verified by simulation and experiment.

The Correlation between Power Error and Velocity Error according to the Condition and Frequency of Self-Controlled Feedback during Knee Extension

  • Yoon, Jung Gyu
    • 국제물리치료학회지
    • /
    • 제9권4호
    • /
    • pp.1602-1607
    • /
    • 2018
  • This study examined the correlation between power error (PE) and velocity error (VE) according to the condition and frequency of self-controlled feedback (SCF) during knee extension. One hundred participants were randomly assigned to 30% SCF, 70% SCF, 30% yoked feedback (YF), 70% YF and control group, respectively. The SCF group was provided with feedback when they requested it, whereas the YF group did not influence the feedback schedule. Participants in the control group were not given any visual feedback during the experiment. The isotonic, isometric, and isokinetic dynamometer (PRIMUS RS, BTE, USA) was used to measure the power and velocity error during knee extension. The collected data was analyzed using a Pearson test and SPSS 21.0. The correlation between PE and VE according to the condition and frequency of feedback on each phase during knee extension was significant. Both PE and VE were significantly higher when the feedback was provided with high frequency, passive, and no feedback. Our study suggests that application of SCF can help to improve the proprioception of the healthy person while reducing errors through low frequency and active feedback.

전력 평형/불평형 경계점 제어를 이용한 전류제어루프에러 MPPT제어기에 관한 연구 (Study on current control loop error MPPT controller using the power balance/unbalance boundary point control)

  • 강태경;고강훈;노순식;강주성;이준엽;우정인;이현우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.292-297
    • /
    • 2005
  • This paper proposes a simple MPPT control scheme of a Current-Control-Loop Error system Based that can be obtains a lot of advantage to compare with another digital control method, P&O and IncCond algorithm, that is applied mostly a PV system. An existent method is needed an expensive processor such as DSP that calculated to change the measure power of a using current and voltage sensor at the once. Therefore, it is applied a small home power generation system that required many expenses. But, a proposed method is easy to solve the cost reduction and power unbalance problems that it is used by control scheme to limit error of a current control of common sensor. This proposed algorithm had verified through a simulation and an experiment on battery charger using PIC that is the microprocessor of a low price.

  • PDF