• 제목/요약/키워드: Power Control Error

검색결과 1,081건 처리시간 0.029초

An integral square error-based model predictive controller for two area load frequency control

  • Kassem, Ahmed M.;Sayed, Khairy;El-Zohri, Emad H.;Ali, Hossam H.
    • Advances in Energy Research
    • /
    • 제5권1호
    • /
    • pp.79-90
    • /
    • 2017
  • The main objective of load frequency control (LFC) is to keep the frequency value at nominal value and force deviation of the frequency to zero in case of load change. This paper suggests LFC by using a model predictive control (MPC), based on Integral Square Error (ISE) method designed to optimize the damping of oscillations in a two-area power system. The MPC is designed and simulated with a model system in state space, for robust performance in the system response. The proposed MPC is tuned by ISE to achieve superior efficiency. Moreover, its performance has been assessed and compared with the PI and PID conventional controllers. The settling time and overshoot with MPC are extremely minimized as compared with conventional controllers.

3레벨 비교기를 이용한 3상인버터의 개선된 히스테리시스 전류제어 기법 (An Improved Current Control Method for Three-Phase PWM Inverters Using Three-Level Comparator)

  • 문형수;한우용;이창구;신동용;김무연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1035-1037
    • /
    • 2001
  • This paper presents an improved hys- teresis current control method for three-phase PWM power inverters using 3-level comparator. Hysteresis current controller using 3-level comparator has an advantage of constant switching frequency compared with conventional hysteresis current controller. However, this method has disadvantage that the longer sampling period, the larger current error because the switching is performed without considering current error magnitude of each phase. The proposed method improves the control performance by selecting the optimum switching pattern in which the magnitudes of current errors are considered introducing space vector concept. Simulation results using Matlab/Simulink show that the proposed control method reduces current error keeping the merit of previous hysteresis current control method.

  • PDF

퍼지 논리를 이용한 온라인 자기동조기능을 갖는 CDMA 셀룰러 시스템용 PID 전력제어기 (On-line self-tuning PID power controller using fuzzy logic for CDMA cellular systems)

  • 김상민;한진욱;김성중
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.211-214
    • /
    • 1997
  • This paper applies fuzzy self-tuning PID controller in DS/CDMA cellular system. Power control is essential in DS/CDMA to compensate for the differing received powers due to both the slowly varying long-term and fast varying short-term fading processes and co-channel interference. The controller proposed is adaptable for the variations of the system dynamics and especially for the variable time delay which exists in mobile radio systems. Accordingly the results is the smaller power control error, that is, the smaller average transmitting power of mobile compared with the conventional control schemes. Because interferences to the other mobiles are reduced, the capacity of CDMA can be increased.

  • PDF

Intelligent Control of Power Plant Using Immune Algorithm Based Multiobjective Fuzzy Optimization

  • Kim, Dong-Hwa
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2003년도 ISIS 2003
    • /
    • pp.525-530
    • /
    • 2003
  • This paper focuses on design of nonlinear power plant controller using immune based multiobjective fuzzy approach. The thermal power plant is typically regulated by the fuel flow rate, the spray flow rate, and the gas recirculation flow rate. However, Strictly maintaining the steam temperature can be difficult due to heating value variation to the fuel source, time delay changes in the main steam temperature. the change of the dynamic characteristics in the steam-turbine system. Up to the present time, PID Controller has been used to operate this system. However, it is very difficult to achieve an optimal PID gain with no experience, since the gain of the PID controller has to be manually tuned by trial and error. These parameters tuned by multiobjective based on immune network algorithms could be used for the tuning of nonlinear power plant.

  • PDF

다상 인터리브드 DC/DC 컨버터를 위한 모델기반의 예측 제어기법 (Model-Based Predictive Control for Interleaved Multi-Phase DC/DC Converters)

  • 최대근;이교범
    • 전력전자학회논문지
    • /
    • 제19권5호
    • /
    • pp.415-421
    • /
    • 2014
  • This study proposes a model-based predictive control for interleaved multi-phase DC/DC converters. The power values necessary to adjust the output voltage in the succeeding are predicted using a converter model. The output power is controlled by selecting the optimal duty cycle. The proposed method does not require controller loops and modulators for converter switching. This method can control the converter by calculating the optimal duty cycle, which minimizes the error between the reference and actual output voltage. The effectiveness of the proposed method is verified through simulations and experiments.

변전소 조상 설비간의 협조 제어를 위한 EMTP 과도해석모형 개발 (EMTP Simulation for the Dynamic Analysis of a STATCOM-Shunts-OLTC Coordination in Substation)

  • 정기석;백영식;박지호;장병훈;이현철;이근준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.237_238
    • /
    • 2009
  • This paper proposes coordinative control method between STATCOM installed within substation and other reactive power resources including Shunt Reactors and Shunt Capacitors and OLTC. Voltage/Reactive power control has various difficult aspects to control because of analysis and system dynamics error. This coordinative control method suggests practical algorithm regarding system voltage and reactive power status which is easy to implement in substation basis. In normal status, STATCOM-Shunts-OLTC are in operation. The proposed algorithm is tested and verified in EMTP/RV. And this is expected to be applied to control multiple reactive power devices combined with SCADA/EMS system.

  • PDF

Analysis and Application of Repetitive Control Scheme for Three-Phase Active Power Filter with Frequency Adaptive Capability

  • Sun, Biaoguang;Xie, Yunxiang;Ma, Hui;Cheng, Li
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.618-628
    • /
    • 2016
  • Active power filter (APF) has been proved as a flexible solution for compensating the harmonic distortion caused by nonlinear loads in power distribution power systems. Digital repetitive control can achieve zero steady-state error tracking of any periodic signal while the sampling points within one repetitive cycle must be a known integer. However, the compensation performance of the APF would be degradation when the grid frequency varies. In this paper, an improved repetitive control scheme with frequency adaptive capability is presented to track any periodic signal with variable grid frequency, where the variable delay items caused by time-varying grid frequency are approximated with Pade approximants. Additionally, the stability criterion of proposed repetitive control scheme is given. A three-phase shunt APF experimental platform with proposed repetitive control scheme is built in our laboratory. Simulation and experimental results demonstrate the effectiveness of the proposed repetitive control scheme.

전파음영 환경에서 적응 어레이 안테나를 적용한 DS/CDMA 셀룰라 시스템의 성능 분석 (The Performance Analysis of a DS/CDMA Cellular System using an Adaptive Array Antenna in Shadowing)

  • 김형채;김항래;김남
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(1)
    • /
    • pp.149-152
    • /
    • 2000
  • In this paper, the reverse link performance of an imperfect power controlled DS/CDMA cellular system that uses a base station array antenna which can effectively remove the multiple access interference is analyzed considering both beam forming algorithm and power control error in shadowing. The blocking probability of the DS/CDMA cellular system based on array parameters, Eb/No and statistics of interference is derived, and then the system capacity corresponding to a certain blocking probability is calculated. On the assumption that the blocking probability is set 1 %, the system capacity using MCGM algorithm with 12 antenna arrays is increased about 59 % than that using 8 antenna arrays when power control error is 2.5 ㏈.

  • PDF

인터넷 가전 제어를 위한 전력선 통신망 채널 특성 추정 기법에 관한 연구 (A systematic method of probing channel characteristics of home power line communication network applied to the Internet accessed control of home appliances)

  • 안남호;장태규;김훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2559-2561
    • /
    • 2002
  • This paper presents a systematic method of probing channel characteristics and communication reliabilities of home PLC (power line communication) network applied to the Internet accessed control of home appliances. The effects of the three performance deterioating factors, i.e., additive noise, channel attenuation, and intersymbol interference, can be systematically measured by applying the channel probing waveform in the frequency range from 100kHz to 450kHz. The agreement between the derived probability of bit error and the measured probability of bit error supports the validity of the proposed approach of probing home power line channel characteristics. The experimental results performed with the constructed test-bed applying the proposed channel probing method also support the feasibility of commercially deploying the PLC modem installed home appliances and their services for the Internet accessed home automation.

  • PDF

광디스크 드라이브에서의 대물렌즈 자동광축보정 (Optical Axis Auto-adjustment of Objective Lens in Optical Disc Drives)

  • 유정래;문정호;조주필
    • 제어로봇시스템학회논문지
    • /
    • 제14권6호
    • /
    • pp.558-563
    • /
    • 2008
  • Optical axis misalignment, which represents the position deviation of the objective lens from the optical axis, is an inevitable assembly error in an optical pick-up. Since the laser power intensity varies with respect to the distance from the optical axis, the misalignment leads to variation of the laser spot power intensity, which is one of the critical factors increasing data bit-error-rate in optical disc drives. In this paper, an auto-adjustment scheme for optical axis alignment is proposed to eliminate the undesirable variation of the laser spot power intensity in optical disc drives. An envelope of the data RF signal is extracted and utilized to detect the optical axis misalignment. Then an adjustment input is added to the driving input of the tracking actuator to shift the objective lens to the optical axis. Finally, the feasibility is verified by experiments.