• 제목/요약/키워드: Power Circuit Breaker

검색결과 328건 처리시간 0.025초

수용가 전기설비 관리자의 PL인식 및 설비사고사례에 관한 실태연구 (The Study on the Actual Condition about Facility Accident Case and PL Recognition of the Safety Manager in Electric Installation for Private Use)

  • 김영석;송길목;정종욱;정진수;김선구;이준
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.309-312
    • /
    • 2008
  • In this paper, we investigated electric safety manager's PL recognition and accident occurrence of electric power facilities(power cable, transformer, circuit breaker) in electric installation for private use. The target of questionnaire survey is 450 electric installations for private use, 154 responded the questionnaire among these and it occupied 35.8%. Most of receiving voltage were 22.900kV. The questionnaire survey says that 58% of electric safety manager knew well about PL contents and 42% of them did not recognize about PL contents, About the PL application of electrical facility accidents, 82.4% of them must applied PL law, 5.8% of them did not need the PL law. Reason of PL application occupied 64% for stability of electrical facility and product, 19% for prevention of same accident. The accident of transformer occupied most and the power cable accident were much next. The questionnaire survey results, electric safety managers are interested in PL content. thev expected necessity of PL application about electrical accident strongly.

  • PDF

HIL 기반 LNGC PMS 시뮬레이터의 성능 검증 (HIL based LNGC PMS Simulator's Performance Verification)

  • 이광국;박재문
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.219-220
    • /
    • 2016
  • 전력 관리 시스템인 PMS는 선박 통합 제어 시스템에서 중요한 역할을 한다. 본 연구에서는 액화 천연가스선의 PMS를 검증하기 위해서 실시간 HIL 시뮬레이션을 구현한다. 시뮬레이터는 터빈 발전기 디젤발전기, 차단기, 주요 3상 부하로 구성되고, 이들 모델은 MATLAB/Simulink로 구현한다. 더불어 FPGA 기반 제어 콘솔과 메인 스위치보드를 구축하여 선박에 탑재 되어 있는 LNGC PMS 제어 환경을 모사 한다. PMS 기능 검증을 위해 LNGC 내 주요 전력소모원 대비 두 가지 전력 분배 모드를 테스트 케이스로 수행한다. 그 결과 본 연구에서 제안한 시스템은 PMS 시뮬레이터로써 시운전 테스트뿐만 아니라 오류 주입 검증용으로 사용될 것이다.

  • PDF

가정용 전기기구의 효과적인 뇌서지 보호기법 (Effective Protection Methods of Household Electric Appliances. from Lightning Surges)

  • 이복희;강성만;엄주홍;이수봉;길형준;구본완;안창환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권3호
    • /
    • pp.149-156
    • /
    • 2004
  • This paper deals with the effective protection method for the household electric appliances against lightning surges invading from the Power lines. Direct or induced lightning is the main cause of the breakdown of household electric appliance. The most effective protection method is to install SPDs(surge protective devices) at household electric appliances. If SPDs were not installed at most household electric appliances, it is necessary to install SPDs on the mains. Therefore the propagation aspect and protection methods of lighting surges coming into household electric appliances through the mains was experimentally investigated. The in actual-sized test circuits results of protection method for 8 household electric appliances including computer monitors and TV set could be summarized as follows: The breakdown characteristics of household electric appliances from lightning surges were significantly changed with the their input impedance. Namely, the types of input impedance are classified into infinite, resistive or inductive impedances. Especially, the monitor for computer with inductive input impedance from lightning surges was relatively weak against lightning surges. It was confirmed that the self inductance of branch circuits on the mains have protection effect for household electric appliances against lightning surges invading from the power lines. Also the varistors installed at cabinet panel or circuit-breaker were more effective than multi-tap outlet with varistors. When installed varistors in cabinet panel and multi-tap outlet together, the surge protection effect is much more excellent in technical and economical aspects.

정온전선의 화재 위험성에 관한 연구 (A Study on the Fire Risk for Self-regulating Heating Cable)

  • 이정현;김시현;박예진;강신동;김재호
    • 한국안전학회지
    • /
    • 제39권3호
    • /
    • pp.7-13
    • /
    • 2024
  • This study examines the physical characteristics of self-regulating heating cables caused by increased temperature and fire risk due to local degradation. A thermo hygrostat system, a convection dryer, a digital multimeter (Agilent 34465 A), NI DAQ, and the LabVIEW program were used to assess the physical properties in response to temperature fluctuations. As the temperature increases, the resistance of the self-regulating heating cable increases; however, when the critical point is exceeded, the resistance sharply decreases. A problem arises when the resistance value cannot return to its original state even though the temperature is lowered to the initial state. Moreover, when the ambient temperature rises while power is applied, the resistance value initially increases, and the flowing current decreases, maintaining a constant state. However, when the critical temperature is exceeded, the flowing current increases because of a rapid decrease in the resistance value, progressing to ignition. When the resistance value decreases because of the deterioration of one local area, the total resistance value becomes less than the initial resistance value. Therefore, the flowing current increases and an ignition problem occurs at one location where deterioration occurs. Despite the sustained flames and arcs resulting from the changes in the overall physical properties of the self-regulating heating cable and resistance variations due to local decline, the fire continued as the flowing current was lower than the operating current of the circuit breaker, failing to cut the power. In the case of self-regulating heating cables and heating wires, which are the leading causes of fires in winter, efforts are needed to ensure the need for periodic maintenance and the use of KS-certified products.

고압배전반의 전기적 안정성 향상을 위한 버스바의 배치기법에 따른 전자기 특성에 관한 연구 (A Study on the Electromagnetic Characteristics of a High Voltage Switchgear According to the Arrangements of Bus Bars to Improve Electrical Stabilities)

  • 남석호;허정일;홍종기;강형구
    • 한국전기전자재료학회논문지
    • /
    • 제26권3호
    • /
    • pp.216-220
    • /
    • 2013
  • The rated voltage has been rising in order to minimize the losses in power transmission. The high voltage electric machines should be minimized due to the constraints of space. Therefore, the temperature of high voltage electric apparatuses easily exceeds the temperature limits. In this paper, it is investigated that how to minimize the internal temperature rising of a high voltage switchgear by adjusting the arrangement of bus bars. High voltage switchgears consist of a circuit breaker, a CT, a PT, a earthing switches, bus bars, and so on. It is very difficult to estimate the electromagnetic properties of a high voltage switchgear due to these various environments and structures. In this paper, analyses are focused on the electromagnetic characteristics of bus bars according to the arrangement method and the enclosures to simplify the electromagnetic characteristics of a switchgear. It is found that the characteristics of electric field intensity and electromagnetic losses in bus bars are influenced by the arrangement method of bus bars. However, it is confirmed that the electromagnetic characteristics of enclosures are not affected by the arrangement of bus bars. In this paper, the arrangement methods of bus bars to minimize the electric field intensity and electromagnetic losses are suggested. It is expected that the research results are helpful to design and develop an electrically reliable high voltage switchgear.

군용항공기 내 비행 영상 및 데이터 녹화기 장착에 관한 안전성 검증 (Safety Verification of Mounting Flight Video and Data Recorder in the Military Aircraft)

  • 권정혁;김경남;황원화;이왕상
    • 항공우주시스템공학회지
    • /
    • 제17권5호
    • /
    • pp.42-57
    • /
    • 2023
  • 본 논문에서는 운영 중인 군용항공기 내에 비행 임무 및 정비사항의 연구 능력 증대를 위해서 비행 영상 및 데이터 녹화기 추가 장착에 대한 운영환경에 맞는 요구도 검토 및 안전성 검증 방안을 연구하였다. 군용규격 및 운영환경에 따른 요구도에 맞도록 녹화기 장비 자체의 검증, 항공기체계에서의 구조 안전성, 전원 및 전기 안전성, 전자기 적합성과 감항 영향성 검토 및 검증과정을 기술하였다. 또한, 지상/비행 시험을 통해 비행 영상 및 데이터 녹화기와 타 계통 간의 간섭 영향성 및 요구도에 적합한 기능 동작 결과도 함께 기술하였다.

진공차단기용 전자식 센서의 선정 및 노이즈 시험에 관한 연구 (A Study on the selection and noise test of elelctronic sensor for Vacuum Circuit Breaker)

  • 이기선;박정철;추순남
    • 한국정보통신학회논문지
    • /
    • 제18권10호
    • /
    • pp.2503-2508
    • /
    • 2014
  • 본 연구는 진공차단기 기계식 보조접점(MOC)의 구조적인 취약성을 해결하기 위해 전자식 센서 기술을 이용한 전자식 보조접점(EOC) 개발에 선행되어야할 센서의 선정 및 노이즈 시험에 관한 것으로, 기존 기계적 보조접점(MOC)에서 발생하는 반복적인 떨림 및 반동 현상에 의한 접점 오동작을 최소화하는 제품을 개발하는 것을 최종 목표로 하였다. 실험 결과, 차단기 투입 및 개방시 개방시의 써지전압 상승속도가 투입시 보다 4.2배 빠른 것으로 측정되었고, 소음크기는 각각 120dB, 110dB로 측정되었다. 상용주파과전압 60kV를 인가하였을 때 진공차단기 투입 및 개방시 센서에서 출력되는 파형은 일그러짐이 없이 정상적으로 동작됨을 알 수 있었다. 그리고 150kV $1.2{\times}50{\mu}s$의 충격파를 인가하였을 때 센서의 투입 및 개방측 출력접점의 전압파형이 일그러짐이 없이 정상상태를 유지하였으며, 2500A의 전류를 인가하였을 때 자계 잡음을 측정한 결과, 전압파형이 일그러짐이 없이 정상적으로 동작하였다.

고분자 분리막을 이용한 혼합가스($SF_6/N_2/O_2/CF_4$)로부터 $SF_6$의 회수 (Recovery of $SF_6$ gas from Gaseous Mixture ($SF_6/N_2/O_2/CF_4$) through Polymeric Membranes)

  • 이현정;이민우;이현경;최호상;이상협
    • 멤브레인
    • /
    • 제21권1호
    • /
    • pp.22-29
    • /
    • 2011
  • 중전기의 유지 보수 및 교체 과정에서 절연체로 사용된 $SF_6$ 가스는 교체 충전과 정제과정에서 유입되는 공기와의 아크 방전에 의해 많은 종류의 부산물($N_2$, $O_2$, $CF_4$, $SO_2$, $H_2O$, HF, $SOF_2$, $CuF_2$, $WO_3$ 등)이 발생된다. 부산물 중에서도 대부분을 차지하는 것이 $N_2$, $O_2$, $CF_4$이며, $SF_6$가스를 재사용하기 위해서는 이들을 효과적으로 분리 회수하는 공정이 필요하다. 주요 부산물인 $N_2$, $O_2$, $CF_4$와의 분리 효율 측면에서 분리막법은 기존의 흡착, 심냉법에 비하여 상대적으로 높은 효율을 보이고 있어 이에 대한 관심 또한 증가하고 있다. 따라서 본 논문에서는 중전기 산업에서 발생되는 $SF_6$ 가스 함유 농도 90 vol% 이상의 가스에 대하여 분리막법을 적용하여 $N_2$, $O_2$, $CF_4$$SF_6$ 가스의 온도와 배출유량의 변화에 따른 분리 회수 가능성을 관찰하였다. PSF와 PC 중공사 분리막을 이용하여 고농도 $SF_6$에 대한 분리 회수 실험 결과, PSF 분리막의 최대 회수율은 압력 0.3 MPa, 온도 $25^{\circ}C$, 배출유량 150 cc/min에서 92.7%를 나타내었으며, PC 분리막에서는 압력 0.3 MPa, 온도 $45^{\circ}C$, 배출유량 150 cc/min 일 때 74.8%의 최대 회수율을 나타내었다. 또한, 사용된 두 가지 분리막과 운전 조건에서 주요 부산물인 $N_2$, $O_2$, $CF_4$의 최대 제거율은 각각 약 80%, 74%, 그리고 58.9%가 관찰되었다. 이로부터 분리막 공정은 고농도 폐 $SF_6$ 가스에서 주요 부산물로부터 $SF_6$의 효과적인 분리 및 회수가 가능한 공정으로 적용할 수 있는 가능성을 파악 할 수 있었다.