• Title/Summary/Keyword: Power Capacity Change of Power Plant

Search Result 46, Processing Time 0.021 seconds

Performance Analysis of Ejector-Pump Thermal Energy Conversion System Using Various Working Fluids (이젝터-펌프 온도차발전시스템의 작동유체별 성능분석)

  • Yoon, Jung-In;Seol, Sung-Hoon;Son, Chang-Hyo;Choi, Kwang-Hwan;Kim, Young-Bok;Lee, Ho-Saeng;Kim, Hyeon-Ju;Moon, Jung-Hyun
    • Journal of Power System Engineering
    • /
    • v.20 no.6
    • /
    • pp.87-92
    • /
    • 2016
  • This research dealt with performance characteristics of OTEC system applying an ejector and additional pump. Each system using five kinds of working fluids was analyzed, and primary parameters with respect to entrainment ratio were examined: Turbine gross power, evaporation capacity, pump work, efficiency and volume flow ratio. The primary results were as following. The efficiency of ejector-pump OTEC system was dependent on entrainment of the ejector. The degree of efficiency change was different from applied working fluid, and amount of pump work was turned out to be primary factor affected system efficiency. Meanwhile, optimized entrainment ratio was different from applied working fluid since their different vapor density. System efficiency at optimized entrainmet ratio of each working fluid was around 5%, showing minor difference each other.

The Estimation of Marine Environmental Capacity for the Reception of Cooling Water from HTPP in Southern Waters of Cheju Island using a 3-D Hydrodynamic Model (화순화력발전소 주변해역의 온배수 환경용량 산정)

  • Kim Gwang-Su;Choi Young-Chan;Lee Moon-Jin
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.3 no.3
    • /
    • pp.3-12
    • /
    • 2000
  • The field surveys and the measurements of seawater temperatures were conducted every month from 1997 to 1999, and the distributions of seawater temperature were simulated and reproduced by a three dimensional hydrodynamic numerical model over the southern waters of Cheju island. In order to estimate the marine environmental capacity for the reception of the heat loads of cooling water discharged from Hwasoon Thermal Power Plant(HTPP) in the study area, the simulations for predicting the situation of unfavorable environment in which marine organisms might not be satisfied with change in seawater temperature were peformed using a three dimensional hydrodynamic numerical model by controlling quantitatively the heat loads of cooling water from HTPP Currently, HTPP discharges cooling water of 35.9℃ into the sea as much as 112,800m³/day in summer. As the results of simulations, the more the heat loads from the power plant increase, the more increase the seawater temperatures around the water areas adjacent to the power plant. In case the heat loads of cooling water from HTPP become about 5 times as high as the present loads, seawater temperatures at near-shore waters adjacent to HTPP appear to be increased to the extent of 0.5℃ above the existing seawater temperature in summer. The marine environmental capacity for the reception of thermal discharge from HTPP is estimated to be about 530×10/sup 6/kcal/day which is equivalent to the increase of a factor of 2 in the temperature of cooling water without any change in the discharge rate of cooling water or which is equivalent to the increase of a factor of 4.6 in the discharge rate of cooling water without any change in the temperature of cooling water. Comparing the case of the increase in the discharge rate of cooling water with the case of the increase in the temperature of cooling water on the basis of the same heat loads of 530×10/sup 6/kal/day, the former case is expected to increase seawater temperature a little higher and to extend the area affected by heat loads a little broader.

  • PDF

Allowable Amount of Bed Inventory in a 300 MW Class Circulating Fluidized Bed Boiler (300 MW 급 유동층보일러에서 적정 층 물질량 산정)

  • Kim, Woo-Yong;Yoo, Ho-seon
    • Plant Journal
    • /
    • v.14 no.2
    • /
    • pp.33-38
    • /
    • 2018
  • The CFB boilers technology is facing a number of challenges. Among them, boiler tube erosion, sintering by bed inventory overheating and high self consumed service power are major ones. This study was conducted to obtain allowable bed inventory with the Yeosu Power Plant, a 300 MW class CFB boiler. For the test, bed pressure was reduced from design pressure of 4.5 KPa to 2.5 KPa by reducing bed inventory, at fixed turbine output, coal consumption rate and air flow. Consequently, reducing the lower bed inventory is effective to decrease bed temperature but excessive reducing might increase bed temperature due to lack of circulating fluidized materials. Also, in case of the Yeosu Plant boiler using subbituminous coal as its primary fuel, its bed temperature change is highly affected by not only the amount of bed inventory, but also the boiler capacity and coal contents.

  • PDF

Vibration Characteristics of a Synchro Clutch Coupling for Steam Turbine (증기터빈용 Synchro Clutch Coupling의 진동 특성)

  • Shim, Eung-Gu;Lee, Tae-Gu;Moon, Seung-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.4 no.3
    • /
    • pp.66-72
    • /
    • 2008
  • The vibration of steam turbine is caused by Mass unbalance, Shaft misalignment, Oil whip and rubbing etc. But in turbine which is normally operated and maintained, the Mass unbalance component possesses the greatest portion. Our power plant has two steam turbines in capacity of 200 MW and 135 MW respectively and each turbine is supported by 6 journal bearings. However, we had many difficulties because the vibration amplitude of #3 and #4 Bearings was high during the start-up and operation mode change of steam turbine. But, with this study, we completely solved the vibration problem caused by the mass unbalance of #1 steam turbine. Until a recent date, #3 and #4 bearings which support high pressure turbine for #1 steam turbine had shown about $135{\mu}m$ in vibration amplitude (sometimes it increased to $221{\mu}m$ maximum. alarm: 6 mils, trip: 9 mils) at base load. After applying the study, they decreased to about $45{\mu}m$ maximum. It is a result from that we did not change the setting value of bearing alignment and only changed the assembly position of internal parts in Synchro clutch coupling rachet wheel which links between high pressure turbine and low pressure turbine, and increased the internal gap and machining of the Pawl cage surface. In the operation of steam turbine, if the vibration value increases by 1X, we should reduce the vibration of bearing by weight balancing. However, unless the vibration of bearing is declined by the balancing, we will have to disassemble and check the component and find the cause. In this study, we researched the way to lower mass unbalance that is 1X vibration component which has the greatest portion of vibration generated by steam turbine and we got good result by applying the findings of this study.

  • PDF

A Case Study on the Reduction of Noise and Vibration at the Backpass Heat Surface in the Power Plant Boiler (발전용 보일러 후부 전열면 소음진동 저감에 관한 연구)

  • Lee, Gyong-Soon;Lee, Tae-Gu;Moon, Seung-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.4 no.3
    • /
    • pp.54-59
    • /
    • 2008
  • The resonance of boiler is caused by exciting force in the gas path and it generates the vibration by the harmony of boiler's dimensional factor. According to trending toward the boiler of increasing capacity and a bigger size, it has a problem of the vibration at back-pass heating surfaces. We can predict such vibrations as comparison between vortex frequency and gas column's natural frequency. We can't rely on the method for the past decades because of changing parameters, such as an allowable error, gas temperature, gas velocity, Strouhal number. We can reduce the vibration to use the seasoning effect and change the operating condition in coal fired boiler but it's not essential solution. When the vibration occurred in the model boiler, we must measures the acoustic pressure and frequency of places for considering the means. So far, we confirmed the problem from field measures and theoretical analysis about the acoustic vibration of boiler. We installed anti-acoustic baffle in a existing boiler to change the acoustic natural frequency at the cavity, which results in reducing the acoustic vibration. The first, we prove that the acoustic resonance is caused by harmonizing vortex shedding frequency of tube heat surface with acoustic natural frequency of cavity in the range of 650~750 MW loads. The second, the acoustic resonance at the back-pass heating surface has the third order of acoustic natural frequency at the second economizer. We install five anti-acoustic baffles at the second economizer to reducing the resonance. We confirm considerably reducing the acoustic vibration of boiler during the commercial boiler.

  • PDF

Ammonia Adsorption Capacity and Breakthrough Curve of Zeolitic Materials Synthesized from Coal Fly Ash (석탄 비산재로부터 합성된 제올라이트의 암모니아의 흡착용량 및 파과특성)

  • Park, Jong-Won;Lee, Chang-Han
    • Journal of Environmental Science International
    • /
    • v.31 no.10
    • /
    • pp.833-844
    • /
    • 2022
  • A zeolite material with a Si/Al molar ratio of 1.2 was synthesized by changing the NaOH/CFA ratio of coal fly ash (CFA) via a fusion/hydrothermal reaction in the HD thermal power plant. The change in the crystal structure of the zeolite was confirmed using XRD and SEM, and the ammonia adsorption capacities of the synthesized zeolitic materials and a commercial zeolite (Na-A zeolite) were analyzed via an ammonia temperature-programmed desorption (NH3-TPD) process. The SEM and XRD results revealed out the zeolitic materials from the coal fly ash maintained a hexagonal Linde-type crystal structure similar to that of Na-A zeolite, but the crystallinity of the synthesized zeolitic material was reduced due to impurities. The NH3 adsorption capacity, determined from the NH3-TPD analysis of was 1.122 mmol/g of the synthesized zeolitic material, which was lower than the NH3 adsorption capacity of the Na-A zeolite.

A Study on the Improvement of Potassium Based Sorbent for Flue Gas Carbon Dioxide(CO2) (배가스 이산화탄소(CO2)용 Potassium계 흡수제의 성능 향상 연구)

  • Wi, Young Ho;Ryu, Chong Kul;Choi, Dong Hyeok
    • Journal of Climate Change Research
    • /
    • v.2 no.2
    • /
    • pp.107-113
    • /
    • 2011
  • In this research, we described the experimental results for the improvement of Potassium based sorbents. These sorbents have been actually used in the 0.5 MW $CO_2$ capture plant located in Hadong #3 Power Plant. Firstly, we had shaped two kinds of sorbents using a spray dryer. These sorbents applied magnetite & copper oxide as an additive. And the magnetite sorbent was evaluated more excellent relatively in the attrition index. Secondly, We had obtained TGA multicycle experimental results of the improved Potassium based sorbent which applied magnetite as an additive. Consequently, $CO_2$ sorption capacity had been sustained 5.5 wt% after 2nd cycle and attrition index was very excellent as 0.5%. Finally, we had investigated the characteristics of the sorbent following in properties of supporters. As a result, the sorption capacity of the KMO sorbent used base material as a supporter was appeared as 7.2 wt%.

An Experimental Study on the Degradation of Polymer in Closed Flow System (밀폐계 유동시스템내에서 고분자물질의 퇴화에 관한 실험적 연구)

  • 김재근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.5
    • /
    • pp.679-686
    • /
    • 1999
  • This study is to investigate the effect of a substantial drag reduction caused by the polymer(A611P) when the working fluids flow to the vertical direction in the vertical cylindrical equipment of closed flow system. The drag reduction is associated with the mechanical degrada-tion thermal degradation and heat transfer. By ignore the heat fluxs within the closed system the pressure drop due to the polymer concentration the flow velocity and flow time have been mea-sured. By taking into account the mechanical and thermal degradation in the closed system an experiment has been focused on the determination of the condition which could improve the pump capacity in the heat union electric power plant. Under the condition of non-boiling it has been found out that the change of heat flux has little influence on the drag reduction.

  • PDF

A Study of JIT-GT Composite Plant Layout (JIT-GT 혼합설비 배치에 관한 연구)

  • Park Jin Hong;Yang Kwang Mo;Cho Jung Hyun;Kang Kyung Sik
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.11a
    • /
    • pp.47-51
    • /
    • 2004
  • Facility layout for enterprise's competitive power strengthening and construction of offensive manufacture line and direction presentation for design of production management system that is new by operation improvement according to S company. In enterprise in JIT(Just in Time) system of leading persons affecting in productions among a lot of habitat factor analyze. It is that through equipment Layout among those factors enterprise my problem improve and serves enterprise's absolute ability cultivation. Even if it is JIT production main point that affect to apply the modular production to productive system among at equipment Layout, lot size, bottleneck session etc. worker's multi-function anger, change of demand factor and productive capacity add. 'S' Through enterprise's example, I wish to establish Korean medium and small enterprises' manufacturing industry style equipment Layout model by taken place effect interpretation.

  • PDF

A Study on Possibility of Sedimentation Basin Omission After Installed Membrane System in Drinking Water Treatment (정수처리시설에서 막공정 도입시 침전공정생략 가능성에 관한 연구)

  • Kim, Hyung-Sun;Zhoh, Choon-Koo;Hong, Seong-Ho;Kim, Sung-Jin;Lee, Kil-Sook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.3
    • /
    • pp.403-410
    • /
    • 2006
  • The objective of this study was to evaluate the possibility of sedimentation basin omission when installed hybrid membrane filtration process in the field plant with the capacity of $500m^3/day$ for 11 months in the "G", water purification plant in Seoul. In order to evaluate the possibility of the sedimentation basin omission, we measured the change of DOC by coagulant dosage. Dosage of PAC(power activated carbon) 4mg/L and coagulant($AI_2O_3$ 10%) 1.67mg/L were compatible to meet the water quality. Also according to the experiment without settlement process, optimization G values were determined to be 300/s, 64/s, and 32/s at the mixing tank, the first flocculator and the second flocculator, respectively. The test was performed under the conditions PAC-coagulation-no settlement-MF. As a result, a dosage of 4.0mg/L as PAC and 0.86 to 1.22mg/L as $Al_2O_3$(10%) in the condition of flux of 62.5LMH were determined to keep TMP value less than $1.0kg_f/cm^2$.