• Title/Summary/Keyword: Power Balance

Search Result 1,156, Processing Time 0.035 seconds

Turbine Cycle Thermal Performance Analysis of Advanced Power Reactor 1400 (신형경수로(APR1400)의 터빈 싸이클 열성능 분석)

  • Jeong, Dae-Yul;Lim, Hyuk-Soon;Jeong, Dae-Wok;Heo, Gyun-Young
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.343-347
    • /
    • 2001
  • Advanced Pressurized Reactor 1400(APR-1400), which is a standard evolutionary advanced light water reactor(ALWR), has been developed from 1992 as one of long-term Government Project(G-7). The APR-1400 is designed to operate at the rated output of 4000MWt to produce an electric power output of around 1450MWe. The balance of plant (BOP) for the secondary system consists of main steam, feedwater, condensate, turbine generator and auxiliary system. In this paper, we describe the major design features of secondary component, balance of plant configuration, and then the turbine cycle thermal performance evaluation using PEPSE code.

  • PDF

A Numerical Study on the Design of Exchanger for Desiccant Dehumidifier (데시칸트 제습기용 열교환기 설계에 관한 수치해석적 연구)

  • Kim, Chi-Wan;Ahn, Young-Chull;Kim, Gil-Tae
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.54-62
    • /
    • 2013
  • A numerical analysis is performed to evaluate mass flow balance in the heat exchanger for the dehumidifier. To improve the mass flow balance for maximum heat transfer performance, inlet, outlet and baffle are changed. Mass flow balance is evaluated by non-uniformity of flow which is the same concept with the standard deviation. Usually, there will occur many paths between the inlet and the outlet, however, it will follow shortest and low resistance ways. The uniform distribution of flow is numerically analyzed for several types of heat exchangers. Making the shortest way between the inlet and the outlet is most important factor. Two types of heat exchangers are installed in the dehumidifier and 4 cases of Type A heat exchangers and 3 cases of Type B heat exchangers are evaluated and optimized. The result of this research is applied to design heat exchanger for commercial dehumidifiers.

Optimal Design of the Hoist Hydraulic System Including the Counter Balance Valve and Differential Cylinder Circuit (카운터밸런스밸브와 차동실린더회로를 포함한 호이스트 유압장치의 최적설계)

  • Lee, S.R.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.5 no.1
    • /
    • pp.13-19
    • /
    • 2008
  • The typical hydraulic system of hoist is composed of a hydraulic supply unit, a directional control valve, counter balance valve, and flow control valves. The flow capacity coefficients of flow control valves should be adjusted so that the hoist is operated at moderate speed and the hydraulic energy loss is minimized. However, it is difficult to adjust the flow coefficients of flow control valves by trial and error for optimal operation. Here, the steady state model of the hoist hydraulic system including the differential cylinder circuit is derived and the optimal flow capacity coefficients of flow control valves are obtained using the complex method that is one kind of constrained direct search method.

  • PDF

DC-Link Capacitor Voltage Balanced Modulation Strategy Based on Three-Level Neutral-Point-Clamped Cascaded Rectifiers

  • Han, Pengcheng;He, Xiaoqiong;Zhao, Zhiqin;Yu, Haolun;Wang, Yi;Peng, Xu;Shu, Zeliang
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.99-107
    • /
    • 2019
  • This study proposes a new modulation strategy to deal with unbalanced output voltage that is based on three-level neutral-point-clamped cascaded rectifiers. The fundament idea is to reallocate the value of the voltage levels generated by each of the modules on the basis of space vector pulse width modulation. This proposed modulation strategy can reduce the switching frequency while maintaining the mutual-module voltage balance. First, an analysis of unbalanced output voltage is reflected. Then a new modulation strategy is introduced in detail. Internal module capacitor voltages are balanced by the selection of redundant vectors. Moreover, the voltage balance ability is calculated. Finally, the feasibility of this modulation strategy is verified through experimental results.

The Effects of Muscle Balance in Lower Limb on Anaerobic Pedaling Capacity among Elite Cyclists (사이클 선수의 하지근력균형이 무산소성 페달링 기능에 미치는 영향)

  • Park, Hyun-Ju;Kim, Jung-Hoon
    • Journal of Digital Convergence
    • /
    • v.17 no.6
    • /
    • pp.389-399
    • /
    • 2019
  • The purpose of this study was to investigate the effects of muscle asymmetry of knee joint among elite cyclists on anaerobic pedaling power related capacity. In another word, based on isokinetic strength of Non-Dominant, ND and Dominant, D, side, high, moderate and low ratio of ND to D were classified as High Symmetry Group, Moderate Symmetry Group and Asymmetry Group, respectively. Analysis of muscle asymmetry of extensor's ND and D side might not lead to any difference between the three groups. Based on muscle strength analysis of the flexor's ND and D, there was statistical difference between the groups in ND flexor and in the muscle balance index of the flexor muscle. This result also leads to significant difference in pedaling power functionality, but this effects might not lead to any negative pedaling power. Therefore, among even cyclists who may show almost the same recruitment pattern of ND and D side during pedaling stroke muscle asymmetry could exist but this phenomena might not negatively contribute to the pedaling capacity.

Factors Influencing Work-life Balance in Female Service Workers (서비스직 여성근로자의 일과 삶의 균형에 영향을 미치는 요인)

  • Cho, Mikyeong;Lee, Hyeonkyeong
    • Korean Journal of Occupational Health Nursing
    • /
    • v.26 no.4
    • /
    • pp.261-272
    • /
    • 2017
  • Purpose: The study aimed to identify factors influencing work-life balance in female service workers. Methods: A cross-sectional descriptive study was conducted with an online survey of 234 service workers using volunteer panels. Data were collected using a self-administered questionnaire from July 16 to 24, 2017. Major variables included work-life balance, resilience, emotional intelligence, job stress, and fatigue. Using the SPSS 24.0 program, descriptive statistics, t-test, ANOVA, correlation analysis, and multiple regression analysis were conducted. Results: The mean score of the work-life balance level of female service workers was $2.9{\pm}0.85$ on a total score of 6. A multiple regression analysis revealed that smoking, resilience, job stress and fatigue were statistically significant factors in the model (p<.001), with an explanatory power of 50.3%. Emotional intelligence was not significantly associated with work-life balance. Conclusion: The level of work-life balance was considerably low in female service workers. This study suggests that nursing interventions to enhance work-life balance are required at both the individual and organizational levels.

Development of Low-Cost and Low-Power Picosatellite Electrical Power Subsystem (저비용/저전력의 초소형위성 전력계의 개발)

  • Park, Je-Hong;Kim, Young-Hyun;Moon, Byoung-Young;Chang, Young-Keun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.7
    • /
    • pp.105-116
    • /
    • 2004
  • The design of pico-/nano-satellites is particularly challenging due to constraints in mass, volume, power, and surface area. An efficient low-cost picosatellite HAUSAT-1 Electrical Power Subsystem (EPS) is developed to supply the power for various loads during the full mission life. This paper addresses design and analysis results of solar arrays, batteries, power conditioning and distribution units. The component selection, manufacturing and test results are presented by considering appropriate development cost and performance. The simulation results of power system are also illustrated, according to operational modes, through energy balance analysis. Finally, the EFS design feasibility is verified by comparing analysis results with functional and environmental test results at the system and component levels, respectively.

The Parallel Operation Control of Static UPSs (정지형 UPS의 병렬운전 제어)

  • Min, Byeong-Gwon;Won, Chung-Yun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.7
    • /
    • pp.363-368
    • /
    • 1999
  • The parallel operation system of multiple uninterruptible power supplies(UPSs) is used to increase power capacity of the system or to secure higher reliability at critical loads. In the parallel operation of the two UPSs, the load-sharing control to maintain the current balance between them is a key technique. Because a UPS has low output impedance and quick response characteristics, in case of an unbalanced load inverter output current changes very rapidly and thereby can instantaneously reach an overload condition. In this study, high precise load-sharing controller is proposed and implemented for the parallel operation system of two UPSs with low impedance characteristics and this controller controls the frequency and the voltage to minimize the active power component and the reactive power component which are gotten from the current difference between two UPSs. And then a good performance of the proposed method is verified by experiments in the parallel operation system with two 40KVA UPSs.

  • PDF

Static Characteristics of Electro-Hydraulic Spring Return Actuator (전기유압식 스프링복귀 액추에이터 정특성)

  • Jung, G.H.
    • Journal of Drive and Control
    • /
    • v.9 no.2
    • /
    • pp.8-14
    • /
    • 2012
  • Electro-hydraulic spring return actuator(ESRA) is utilized for air conditioning facilities in a nuclear power plant. It features self-contained, hydraulic power that is integrally coupled to a single acting hydraulic cylinder and provides efficient and precise linear control of valves as well as return of the actuator to the de-energized position upon loss of power. In this paper, the algebraic equations of ESRA at steady-state have been developed for the analysis of static characteristics that includes control pressure and valve displacement of pressure reducing valve, flow force on flapper as well as its displacement over the entire operating range. Also, the effect of external load on piston deviation is investigated in terms of linear system analysis. The results of static characteristics show the unique feature of force balance mechanism and can be applied to the stable self-controlled mechanical system design of ESAR.

Experimental Methods for the Measurement of Damping Loss Factors (내부손실계수 측정을 위한 실험 방법)

  • 김관주;최승권
    • Journal of KSNVE
    • /
    • v.9 no.6
    • /
    • pp.1187-1192
    • /
    • 1999
  • The purpose of this study is to determine the most appropriate experimental method of the measurement of "damping loss factors" (DLF) for the statistical energy analysis(SEA) calculation. The successful prediction of vibration levels from the structure is critically dependent on the accurate estimation of DLF's not only in conventional vibration analysis but especially in SEA. Unforunately, calculation of accurate DLF is not an easy matter. So experimental methods are made use of for the DLF values. Three kinds of experimental methods for estimating DLF, i.e. decay rate method, half-power bandwidth method and power balance method, are presented and tests are carried out for the plate and the cylindrical shell examples. Pro and con of each methods is reviewed. Finally, calculated DLF values are used for vibration level estimation using commercial SEA software and compared with measured vibration data.tion data.

  • PDF