• Title/Summary/Keyword: Potentiometric

Search Result 239, Processing Time 0.02 seconds

The Composition Dependence Selectivity Changes by Plasticizer at the Cation Sensors Based on Tetracycline Antibiotics

  • Baek, Jong-Gyu;Kim, Jin-San;Paeng, Insook Rhee;Paeng, Ki-Jung
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.1
    • /
    • pp.165-167
    • /
    • 2008
  • The performances of tetracycline based cation selective polymeric membrane electrodes of many sets with different plasticizers were investigated as the selectivity of ion-selective electrodes and optodes are greatly influenced by membrane solvent and also controlled by plasticizers. The membrane 1 with Bis(2-ethylhexyl) sebacate (DOS) and additive shows good potentiometric performance toward Ca2+ (slope: 27.8 mV per decade; DL: -4.52) including selectivity. Contrastingly, membrane 4 with Dibutyl phthalate (DBP) shows near-Nernstian response, it has also shown the best measuring range and detection limit for Ca2+ (29.5 mV and -5.10) and Mg2+ (24.4 mV and -5.04) and the least selectivity has been also observed between Ca2+ and Mg2+. When the membrane 1 and 4 were used together to flow system, we could determine the concentration of Ca2+ and Mg2+, simultaneously.

Synthesis of Schiff-Base Ligands and Determination of Stability Constants of Their Transition Metal(II) Complexes (질소-산소계 시프염기 리간드의 합성과 전이금속(II) 착물의 안정도상수결정)

  • Kim, Seon Deok;Song, Chan Ik;Kim, Jun Gwang;Kim, Jeong Seong
    • Journal of Environmental Science International
    • /
    • v.13 no.9
    • /
    • pp.835-843
    • /
    • 2004
  • N,N-bis(2-salicylaldehyde)dipropylenetriamine(5- Hsaldipn), N,N-bis( 5-bromosalicyl-aldehyde) dipropylenetriamine (5-Brsaldipn), N,N-bis(5-chlorosalicy laldehyde )dipropylene-triamine(5-Clsaldipn), N,N-bis(2-hydroxy- $5-methoxy-benzaldehyde)dipropylenetriamine(5-OCH_3saldipn)$ and N,N-bis (2-hydroxy-5-nitrobenzaldehyde)dipropylenetriamine $(5-NO_2saldipn)$ were synthesized and characterized by elemental analysis, infrared spectrometry, NMR spectrometry and mass spectrometry. Their proton dissociation constants were determined in 70% dioxane/30% water solution by potentiometric. Stability constants of the complexes between these ligands and the metal ions such as Cu(II), Ni(II) and Zn(II) were measured in dimethyl sulfoxide by a polarographic method. Stability constants for the ligands were in the order of $5-OCH_3$ > 5-H > 5-Br > 5-Cl > $5-NO_2$ saldipn. Enthalpy and entropy changes were obtained in negative values.

Characteristics of Conducting Polymer-based Urea Sensors with Planar Pt Electrode on Silicon Substrate (전도성 고분자를 이용한 요소 측정용 반도체 바이오센서의 특성)

  • Park, Sung-Ho;Jin, Joon-Hyung;Min, Nam-Ki;Hong, Suk-In
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1454-1456
    • /
    • 2001
  • 신장병 진단에 중요한 요소의 농도를 측정하기 위한 요소 센서를 반도체 위에 개발이 연구의 목적이다. 센서의 감도 측정은 선형 전위 주사법(Linear sweep voltammtry)을 이용하였다. 선형 전위 주사법은 가역적이든 비가역적이든 관계없이 cottrell 식에 의한 전류와 농도의 직선관계로부터 감도를 측정할 수 있는 장점이 있고 또한 저 농도에서 민감하게 반응한다. 따라서 기존 전위차 측정형 바이오 센서(Potentiometric biosensor)에서 규명할 수 없는 감도 문제를 선형 전위 주사법으로 규명하고자 하였다. 센서전극은 p-type 실리콘 웨이퍼 위에 전극을 제작했다. 그 위에 cyclic voltammetry 법을 사용하여 전도성 고분자를 전기 중합 하였고, 그위에 다시 chronoamperometry법을 사용하여 우레아제를 고정화 하여 작업전극으로 제작하였다. 센서의 감도는 phosphate buffer 용액(pH7.4)속에서 온도 35$^{\circ}C$를 유지하며 측정하였다.

  • PDF

고분자 물질을 사용한 토양 중 방사성 핵종의 고정화

  • 원휘준;김계남;김민길;오원진
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.293-297
    • /
    • 2003
  • A series of laboratory experiments was conducted to investigate the fixation characteristics of poly(vinylalcohol)-poly(methacrylic acid)(PVA-PMAA) mixed solution on the soluble (equation omitted)-radionuclides. Using the potentiometric titration technique, it was found out that the PVA and PMAA in a solution form intermacromolecular complex. The mobilized portion of each radionuclide by water from sand surface treated with a fixative was measured by ${\gamma}$-ray spectroscopy, The mobilized portion of minor radionuclides such as $^{241}$ Am, $^{154}$ Eu, $^{155}$ Eu and $^{144}$ Ce were higher than those of $^{134}$ Cs and $^{137}$ Cs. The capability of PVA-PMAA system was better among the candidate solutions for the fixation of total (equation omitted)-radioactivity, $^{134,137}$Cs which is composed of more than 85 % of total ${\gamma}$-radioactivity could be fixed effectively by the PVA-PMAA solution.

  • PDF

Simple Iysine sensing system using $CO_{2}$ electrode and enzyme immobilized to CNBr-activated sepharose 4B

  • Kim, Eun-Jung;Koh, Kwang-Nak;Choi, Myung-Sook
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.437-444
    • /
    • 1997
  • A potentiometric L-lysine-selective sensor is described for the direct determination of lysine. The sensor system is based on a carbon dioxide gas sensing electrode and an L-lysine decarboxylase immobilized to CNBr-activated sepharose 4B. A highly selective L-lysine sensor has been prepared with immobilizing enzyme slurry put into reaction buffer solution. The optimum conditions for the measurement were evaluated by various experiments. This sensor exhibits a linear response to L-lysine concentrations from $10^{-4}M$ to $10^{-1}M$. Response time of this lysine sensor is shorter than 30secs and the immobilized enzyme slurry is stable over one year.

  • PDF

Evaluation of Chloride Ion Binding Capacity of Hardened Portland Cement Paste Containing Hydrotalcite (경화된 하이드로탈사이트 혼입 포틀랜드 시멘트 페이스트의 염소이온 고정능력 평가)

  • Han, Jae-Do;Lee, Yun-Su;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.27-28
    • /
    • 2018
  • Deterioration of reinforced concrete structures due to salt corrosion is a phenomenon that can be easily seen, and the main reason for deterioration is chloride ion. Therefore, researches are actively conducted to control chlorine ion penetration worldwide. The purpose of this study is to evaluate the chloride ion fixation capacity of Portland cement paste containing Hydrotalcite. For this purpose, cement paste containing 0%, 2.5%, and 5% of Hydrotalcite was sealed and cured for 28 days, and the cured cement paste was crushed. Chloride ion solution was prepared at a concentration of 0.5M using NaCl, and the powdered cement paste was reacted for a specific time in aqueous chloride ion solution. After the reaction, the concentration of the chloride ion aqueous solution was measured using a silver nitrate potentiometric titrator, and the reacted cement paste was analyzed using XRD and FT-IR.

  • PDF

The Interfacial of Ferrosoferric Oxide in Aqueous Potassium Nitrate Solution

  • Shim, Kyoo-Shik;Takyue Ree
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.12 no.1
    • /
    • pp.17-33
    • /
    • 1986
  • The interfacial Properties of ferrosoferric oxide suspended in aqueous KNO3 solution are investigated by studying the zeta potentials and surface charge densities at $25^{\circ}C$. The zeta potentials are obtained by measuring the electrophoretic mobility and the surface charge densities by potentiometric titrations in the aqueous KNO3 solutions of different concentrations from 10-3 to 10-1M. The data are interpreted by the surface dissociation and complexation model of Davis, et als. and the modified model.

  • PDF

Characteristics of Enzyme Sensors using Carboxylated PVC for Immobilizing Penicillinase (Carboxylated PVC에 페니실리나제를 고정한 효소 센서의 특성)

  • Kim, Ki-Myo;Kim, Young-Hak;Lee, Eun-Yup;Hur, Moon-Hye;Ahn, Moon-Kyu
    • YAKHAK HOEJI
    • /
    • v.40 no.1
    • /
    • pp.72-77
    • /
    • 1996
  • Penicillin sensor was manufactured by immobillizing penicillinase with glutaraldehyde on the $H^+$-selective membrane based on PVC-COOH-TDDA. This membrane was not inter fered by $K^+$ ion in Pc-G potassium salt. When enzyme was immobilized with glutaraldehyde, the PVC-COOH matrix was more effective than PVC matrix. Calibration curve calculated from Nernst equation was not linear. But potential was relative to concentration of Pc-G. And maximal potentiometric velocity was also relative to concentration of Pc-G. Therefore, it may be applied to Michaelis-Menten equation. The penicillin sensor was useful for determination of Pc-G at concentration of 0.1~10mM level.

  • PDF

Determination of Acidic Drug with ISEs Using Ternary Complex of Metal-di-2-pyridyl Ketone Oxime-acidic Drug as Ion-Exchanger (이온교환체로서 금속-디-2-피리딜케톤옥심-산성의약품 3원 착물을 이용한 산성의약품의 정량)

  • 안문규;오원정;이언경;이순영;이재윤;정문모;허문회
    • YAKHAK HOEJI
    • /
    • v.46 no.5
    • /
    • pp.320-323
    • /
    • 2002
  • A method for the determination of acidic drug, mefenamic acid and ibuprofen with ion-selective electrode(ISE) using Fe(II)-di-2-pyridyl ketone oxime complex as a counter ion were developed. Benzyl-2-nitrophenyl ether(BNPE) plasticized membrane was more selective and sensitive than the other tested membranes. The acidic drug selective electrode exhibits a linear response for 10$^{-2}$ M 510$^{-5}$ M of acidic drugs, mefenamic acid and ibuprofen with a slope of -55.9 and -56.3 mV/dec. in borate buffer solution (pH 8.9). Potentiometric selectivity measurements revealed negligible interferences from aromatic and aliphatic carboxylic acid salts. The electrodes were found to be useful for the direct determination of mefenamic acid and ibuprofen in pharmaceutical preparations.