• Title/Summary/Keyword: Potential Transformer

Search Result 130, Processing Time 0.038 seconds

A Numerical Model of the Electric Field Distribution in Power Transformers (전력용 변압기의 절연유가 전계에 미치는 수치해석적 모델)

  • Shin, Pan-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.3-6
    • /
    • 1990
  • The impact of the convected charges, which is caused by the electrification phenomina, in the oil-paper insulation systems of power transformers has been numerically investigated using FEM. The potential distribution of the oil-paper insulation system is assumed to be governed by three equations instead of the classical Laplace equation. When the charge density of oil and the conduction current are kept high, the field distortion or the interrace in a power transformer is considerably distorted due to the convected charges.

  • PDF

Development of 132 kV Standard Potential Transformer and Stability Test (132 kV 초정밀 전압변성기(PT) 개발 및 안정도 평가)

  • Kwon, Sung-Won;Lee, Sang-Hwa;Jung, Jae-Kap;Kim, Mun-Seog;Kim, Jae-Young;Lee, Sung-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1387_1388
    • /
    • 2009
  • High accurate and stable 132 kV potential transformers (PTs) including 66 kV & 22 kV PT with stability of less than 0.0033 % for 13 month and with ratio error within $\pm$ 0.024 % at full rated voltage have been developed. The PTs are useful as the reference PT of the PT comparator system in the voltage range of 11 kV to 132 kV PT.

  • PDF

Analysis on the Protective Coordination with Hybrid Superconducting Fault Current Limiter (저항접지 시스템에서 지락사고시 CLR과열 소손방지를 위한 GPT 정격용량의 적정성 연구)

  • Shin, Ho-Jeon;Kim, Jin-Seok;Park, Yu-Hwan;Kim, Jae-Chul;Cho, Man-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.4
    • /
    • pp.503-508
    • /
    • 2012
  • Among the high distribution voltage consumers, high-capacity consumers are often applying the grounding resistance method in order to overcome demerits such as erroneous operation of the ground reply or potential increase in the battery at the accident of the isolated neutral system. In this paper, to prevent damage to CLR and GPT in the delay to block the breakdown in the resistance grounded neutral system, this study aims to provide a proper suggestion for continuous rating capacity of GPT to check the appropriateness of CLR size and reduce GPT burden. Thereupon, this study comparatively analyzes CLR current applied in general GPT and the current gained when CLR demanded in the system is used and analyzes the simulated system through simulation using PSCAD/EMTDC in order to suggest GPT's proper continuous rating capacity.

A study on an earthing system without ground connection (대지에 매설할 필요가 없는 접지시스템에 관한 연구)

  • Seol, Dong-Hwa;Kim, Chang-Bong;Woo, Jea-Wook
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.258-261
    • /
    • 2009
  • This paper proposes an earthing system without ground connection. As a Green IT Environmental Solution, Internal-external surge and other unnecessary electric currents are converted into energy and through a discharge the signal is reduced. It's a structure that discharges through a neutral electric transformer. The results show that the electric potential rising of the earthing system proposed in this paper are approximately below the half and the discharge currents increased approximately 9 times when compared to existent earthing systems. This earthing system is economical, easy to install and can solve environmental contamination.

  • PDF

The Performance of Cathodic Protection with ICCP

  • Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.8
    • /
    • pp.1286-1290
    • /
    • 2004
  • This paper describes the anti-corrosion system on underwater structures of ships. Metals and alloys have several positions in the series such as immunity, corrosion and passivity. The iron potential has to change from the corrosion position to the anodic protection or cathodic protection for preventing corrosion by providing corrosion protection system such as ICCP(Impressed Current Cathodic Protection). The purpose of ICCP system is to eliminate the rusting or corrosion, which occurs on metal immersed in water. The system includes a power supply unit, which consists of a transformer, a converter. a controller, etc. This paper presents the protection performance of ICCP under dynamic condition such as velocity. The variation of potential and current density with time and environment factors are also described Finally, the experimental results will be explained and analysed.

유도 결합 플라즈마에서 밸런스 파워에 의한 전자밀도의 증가 효과

  • Kim, Hyeon-Jun;Choe, Ik-Jin;Lee, Yeong-Gwang;Jeong, Jin-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.219-219
    • /
    • 2011
  • 공정용 유도 결합 플라즈마(ICP)에서 강자성체인 페라이트를 이용하여 제작한 발룬 변압기(balun transformer)를 사용하여 플라즈마 밀도를 높이는 실험을 수행하였다. 실험에서는 2개의 발룬 변압기를 이중구조 안테나에 설치하여 실제 인가되는 전압이 접지전위 대비+V에서 ${\pm}$V/2로 변환되도록 구성하였다. 20~100 mTorr 압력 범위의 아르곤 기체 50 sccm에 30~70 W범위의 전력을 인가하여 반응용기의 중앙과 벽면에서 부유 탐침법을 적용하여 플라즈마 밀도를 측정 하였다. 같은 압력과 같은 전력에서 발룬 변압기를 사용했을 때와 회로에서 변압기만 제거한 실험을 비교하면 반응용기 중앙에서 플라즈마 밀도가 평균 10% 증가함을 보였다. 이는 안테나에 발란스 된 전압이 인가되면 플라즈마 균일도가 증가하고 부유전위(floating potential) 대비 플라즈마 전위(plasma potential)가 낮아져서 이온에 의한 손실이 줄어들어 전자가 더 많은 에너지를 흡수해서 나타나는 현상이다. 특히 E-mode에서 H-mode로 전환되면 플라즈마 밀도가 크게 증가함을 보였고, 반응용기 벽면에서는 발룬 변압기를 사용했을 때 밀도가 낮다가 H-mode로 전환 시 비교실험 대비 밀도가 크게 증가함을 볼 수 있었다.

  • PDF

Seismic mitigation of substation cable connected equipment using friction pendulum systems

  • Karami-Mohammadi, Reza;Mirtaheri, Masoud;Salkhordeh, Mojtaba;Mosaffa, Erfan;Mahdavi, Golsa;Hariri-Ardebili, Mohammad Amin
    • Structural Engineering and Mechanics
    • /
    • v.72 no.6
    • /
    • pp.785-796
    • /
    • 2019
  • Power transmission substations are susceptible to potential damage under seismic excitations. Two of the major seismic failure modes in substation supplies are: the breakage of brittle insulator, and conductor end fittings. This paper presents efficient isolation strategies for seismically strengthening of a two-item set of equipment including capacitive voltage transformer (CVT) adjacent to a Lightning Arrester (LA). Two different strategies are proposed, Case A: implementation of base isolation at the base of the CVT, while the LA is kept fixed-base, and Case B: implementation of base isolation at the base of the LA, while the CVT is kept fixed-base. Both CVT and LA are connected to each other using a cable during the dynamic excitation. The probabilistic seismic behavior is measured by Incremental Dynamic Analysis (IDA), and a series of appropriate damage states are proposed. Finally, the fragility curves are derived for both the systems. It is found that Friction Pendulum System (FPS) isolator has the potential of decreasing flexural stresses caused by intense ground motions. The research has shown that when the FPS is placed under LA, i.e. Case B (as oppose to Case A), the efficiency of the system is improved in terms of reducing the forces and stresses at the bottom of the porcelain. Several parametric studies are also performed to determine the optimum physical properties of the FPS.

Improving Explainability of Generative Pre-trained Transformer Model for Classification of Construction Accident Types: Validation of Saliency Visualization

  • Byunghee YOO;Yuncheul WOO;Jinwoo KIM;Moonseo PARK;Changbum Ryan AHN
    • International conference on construction engineering and project management
    • /
    • 2024.07a
    • /
    • pp.1284-1284
    • /
    • 2024
  • Leveraging large language models and safety accident report data has unique potential for analyzing construction accidents, including the classification of accident types, injured parts, and work processes, using unstructured free text accident scenarios. We previously proposed a novel approach that harnesses the power of fine-tuned Generative Pre-trained Transformer to classify 6 types of construction accidents (caught-in-between, cuts, falls, struck-by, trips, and other) with an accuracy of 82.33%. Furthermore, we proposed a novel methodology, saliency visualization, to discern which words are deemed important by black box models within a sentence associated with construction accidents. It helps understand how individual words in an input sentence affect the final output and seeks to make the model's prediction accuracy more understandable and interpretable for users. This involves deliberately altering the position of words within a sentence to reveal their specific roles in shaping the overall output. However, the validation of saliency visualization results remains insufficient and needs further analysis. In this context, this study aims to qualitatively validate the effectiveness of saliency visualization methods. In the exploration of saliency visualization, the elements with the highest importance scores were qualitatively validated against the construction accident risk factors (e.g., "the 4m pipe," "ear," "to extract staircase") emerging from Construction Safety Management's Integrated Information data scenarios provided by the Ministry of Land, Infrastructure, and Transport, Republic of Korea. Additionally, construction accident precursors (e.g., "grinding," "pipe," "slippery floor") identified from existing literature, which are early indicators or warning signs of potential accidents, were compared with the words with the highest importance scores of saliency visualization. We observed that the words from the saliency visualization are included in the pre-identified accident precursors and risk factors. This study highlights how employing saliency visualization enhances the interpretability of models based on large language processing, providing valuable insights into the underlying causes driving accident predictions.

Aging Characteristics of Power Transformer Oil and Development of its Analysis using KOSM (전력용 변압기유의 열화 특성에 KSOM에 의한 분석기법 개발)

  • 임재윤;지평식;이종필;남상천;이승렬
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.3
    • /
    • pp.56-63
    • /
    • 1999
  • In power system, substation facilities have become too complex and large according to extended power system. Also, some facilities becorre old and often break down unexpectedly. In order to improve the sectrity of transformer out of substation facilities, the development of diagnosis technique to transformer is very needed. In this paper, we developed a method to be analysis the origin and degree of aging by KSOM based on the dissolved gases in power transfonrer. KSOM can do topological mapping for the multi-dimensional pattern based on the dissolved gases to two dimensional plane. And potential possibility and degree of aging for nonna1 transfonrer are presented using the proposed quantitative criterion. Furtherrrore, the aging process of transfonrer is analyzed based on the proposed criterion to special transfonrer. To demonstrate the validity of peoposed method, case study is performed and its results are presented.sented.

  • PDF

A Study on the Effects of I&C Systems by EMI Generating from Corona Discharge at Transformer Area (변압기 지역 코로나 전자파 간섭에 의한 계측제어설비 영향에 관한 연구)

  • Min, Moon-Gi;Lee, Jae-Ki;Park, Jin-Yeub;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.266-271
    • /
    • 2014
  • The Electromagnetic Interference(EMI) generating from corona discharge of transformer area can interference the digital Instrument and Control(I&C) systems located nearby transformers. When the potential gradient of the electric field around the conductor is high enough to form a conductive region but not high enough to cause electrical breakdown to nearby objects, the EMI of corona discharge emits with the conducted and radiated noise and it interferences the signals of the I&C systems. Since digital I&C systems have an efficiency and competitive price, the analog I&C systems have been upgraded and displaced with the digital I&C systems but which have less EMI Immunity. There was no assessment to I&C systems by EMI generating corona discharge nearby transformers. When the safety-related I&C systems are installed in plants, the verification of equipment EMI should be done not in site-specific test but in test facilities. There are the need to do the site-specific EMI evaluation of corona discharge nearby transformers. This paper assesses the margin between plant emission limits and the highest composite plant emission of corona. When the non safety-related I&C systems are placed in transformer area, it suggests the appropriate radiated susceptibility level to EMI of corona discharge.