Abstract

In power system, substation facilities have become too complex and large according to extended power system. Also, some facilities becorre old and often break down unexpectedly. In order to improve the sectrity of transformer out of substation facilities, the development of diagnosis technique to transformer is very needed. In this paper, we developed a method to be analysis the origin and degree of aging by KSOM based on the dissolved gases in power transfonrer. KSOM can do topological mapping for the multi-dimensional pattern based on the dissolved gases to two dimensional plane. And potential possibility and degree of aging for nonna1 transfonrer are presented using the proposed quantitative criterion. Furtherrrore, the aging process of transfonrer is analyzed based on the proposed criterion to special transfonrer. To demonstrate the validity of peoposed method, case study is performed and its results are presented.sented.

전력계통의 변전소 설비들은 계통의 확장에 따라 점점 복잡하고 거대해지고 있다. 또한, 몇몇 장비들은 점점 노후되고, 종종 예상치 않은 고장을 일으킨다. 변전소 설비들 중 변압기의 신뢰도를 증가시키기 위해서, 변압기의 진단기법 개발이 매우 필요하다. 본 연구에서는, 전력용 변압기의 용해 가스들을 근거로 KSOM(Kohonen Self Organizing Map)에 의한 열화정도와 원인의 분석기법을 개발하였다. KOSM은 용해가스에 의해 구성된 다차원 패텅을 이차원 평면에 지형학적 맵핑이 가능하다. 그리고 정장변압기에 대한 열화의 정도와 잠재적인 열화의 가능성을 제안된 정량적 지표에 의해 제시하였다. 아울러, 변압기의 열화과정을 제안된 지표를 근거로 특정한 변압기에 대해 분석하였다. 제안된 방법의 타당성을 입증하기 위해서 사례연구가 수행되고, 그 결과를 제시하였다.

Keywords

References

  1. IEEE Trans. on Electrical Insulation v.B-21 no.2 New Apparatus For detecting Transformer Faults H.Tsukioka;K.Sugawara;E.Mori;H.Yamaguchi
  2. 電氣協同硏究 v.36 no.1 油中ガス分析による油入機器保守管理 電氣協同硏究會
  3. 電氣學會論文誌 v.94 no.2 油入變壓器の油中ガス分析による絶緣異常診斷法(第1報) 木下仁志 他
  4. T.IEE v.112-B no.3 配電用油入變壓器のポ-タプル形診斷技術最新動向 村田孝一;安田眞司
  5. IEEE Trans. Electr. Insul v.B-13 no.5 IEEE And IEC Code To Interpret Incipient Faults in Transformers Using Gas in Oil Analysis R.R.Rogers
  6. 전력연구원 연구보고서 변압기 유중가스 상시 감시시스템의 운용 연구 남창현(외)
  7. IEEE Trans. v.PAS-100 Automatic Field Monitoring of Dissolved Gases in Transfomer Oil Y.Kashima
  8. IEEE Electrical Insulation Magazine v.5 no.6 Dissolved Gas Analysis:It Can Save Your Transformer M.Duval
  9. IEEE Trans. Electr. Insul. v.B-22 no.6 Degradation of Insulating Materials of Transformers H.Yoshida;Y.Ishioka;T.Suzuki;T.Yanari;T.Teranishi
  10. IEEE Trans. Electr. Insul. v.B-21 no.6 Diagnostic Methods for Power Transformer Insulation Y.Kamata
  11. IEEE Trans. Electr. Insul. v.B-13 no.4 New Apparatus for Detecting H2, CO and CH4 Dissolved in Transformer Oil H.Tsukioka;K.Sugawara;E.Mori;S.Hukumori;S.Sakai
  12. Neural Computer Theory and Practice Philip D. Wasserman
  13. Neural Network in computer Intelligence LiMin Fu
  14. Proceedings of International Joint conference on Neural Network Self-Organizing Map As a New Method for Clustring and Data Analysis Xuegong Zhang;Yanda Li
  15. 전기학회논문지 v.47 no.6 유중가스 분석을 이용한 전력용 변압기 고장진단용 코호넨 네트워크 윤용한;전영재;김재철
  16. ICEE'98 v.Ⅱ Aging Characteristics Power Transformer Oil and Development of It's Analysis Using KSOM J.P.Lee(et al.)