• Title/Summary/Keyword: Post-structural

Search Result 1,242, Processing Time 0.03 seconds

Application of Post-Tension Technology on Tall Buildings

  • Chung, Kwangryang;Park, Jungwoo;Kim, Younghye;Kim, Dohun
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.3
    • /
    • pp.285-296
    • /
    • 2017
  • It's been a decade since post-tension system began to be applied in earnest to buildings in Korea. In the meantime, post-tension system has been used in various buildings as main structural system including tall buildings. And post-tension system plays a role to overcome architectural limit of regular RC tall buildings particularly in the realization of long span with shallower depth than other structural system. The post-tensioned building market of Korea has been steadily grown in recent years with such advantage. Recently, post-tension technology is adapted for special structural members like belt walls. In this paper, the authors would like to explain design and construction of tall buildings in Korea using post-tension technology.

Computer vision and deep learning-based post-earthquake intelligent assessment of engineering structures: Technological status and challenges

  • T. Jin;X.W. Ye;W.M. Que;S.Y. Ma
    • Smart Structures and Systems
    • /
    • v.31 no.4
    • /
    • pp.311-323
    • /
    • 2023
  • Ever since ancient times, earthquakes have been a major threat to the civil infrastructures and the safety of human beings. The majority of casualties in earthquake disasters are caused by the damaged civil infrastructures but not by the earthquake itself. Therefore, the efficient and accurate post-earthquake assessment of the conditions of structural damage has been an urgent need for human society. Traditional ways for post-earthquake structural assessment rely heavily on field investigation by experienced experts, yet, it is inevitably subjective and inefficient. Structural response data are also applied to assess the damage; however, it requires mounted sensor networks in advance and it is not intuitional. As many types of damaged states of structures are visible, computer vision-based post-earthquake structural assessment has attracted great attention among the engineers and scholars. With the development of image acquisition sensors, computing resources and deep learning algorithms, deep learning-based post-earthquake structural assessment has gradually shown potential in dealing with image acquisition and processing tasks. This paper comprehensively reviews the state-of-the-art studies of deep learning-based post-earthquake structural assessment in recent years. The conventional way of image processing and machine learning-based structural assessment are presented briefly. The workflow of the methodology for computer vision and deep learning-based post-earthquake structural assessment was introduced. Then, applications of assessment for multiple civil infrastructures are presented in detail. Finally, the challenges of current studies are summarized for reference in future works to improve the efficiency, robustness and accuracy in this field.

The Experimental and Analytical Study on the Behavior of Composite Beam in the Processing of External Post Prestressing strengthen (외부 후긴장 보강 과정의 합성보 거동에 대한 실험 및 해석적 연구)

  • Park, Yong-Gul;Park, Young-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.4
    • /
    • pp.147-153
    • /
    • 2001
  • The major objectives of this study are to investigate experimental and analytical behavior of composite steel plate strengthened by external post prestressing method and to study the increasing magnitude of load carrying capacity by the external post prestressing method. With installed strain gauges and LVDT, the change of structural behaviors according to the amount of prestressing force is measured and the effects of shear strengthening according to the degree of angle in tendon are studied. The analytical structural behavior according to the amount of prestressing force is also investigated using finite element method. The effectiveness of strengthening of external post prestressing method is proved and an efficient FEM model is suggested by comparing the test results and analyzing results.

  • PDF

Post-fire Repair of Concrete Structural Members: A Review on Fire Conditions and Recovered Performance

  • Qiu, Jin;Jiang, Liming;Usmani, Asif
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.4
    • /
    • pp.323-334
    • /
    • 2021
  • Concrete structures may rarely collapse in fire incidents but fire induced damage to structural members is inevitable as a result of material degradation and thermal expansion. This requires certain repairing measures to be applied to restore the performance of post-fire members. A brief review on investigation of post-fire damage of concrete material and concrete structural members is presented in this paper, followed by a review of post-fire repair research regarding various types of repairing techniques (FRP, steel plate, and concrete section enlargement) and different type of structural members including columns, beams, and slabs. Particularly, the fire scenarios adopted in these studies leading to damage are categorized as three levels according to the duration of gas-phase temperature above 600℃ (t600). The repair effectiveness in terms of recovered performance of concrete structural members compared to the initial undamaged performance has been summarized and compared regarding the repairing techniques and fire intensity levels. The complied results have shown that recovering the ultimate strength is achievable but the stiffness recovery is difficult. Moreover, the current fire loading scenarios adopted in the post-fire repair research are mostly idealized as constant heating rates or standard fire curves, which may have produced unrealistic fire damage patterns and the associated repairing techniques may be not practical. For future studies, the realistic fire impact and the system-level structural damage investigation are necessary.

DEVELOPMENT OF A PRE_ AND POST_ PROCESSOR FOR STRUCTURAL ANALYSIS USING A RELATIONAL DATABASE MANAGING SYSTEM (관계형 데이터베이스를 이용하는 구조해석 전후처리기의 개발)

  • 이대희;이호재;이정재
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.176-179
    • /
    • 1998
  • In structural analysis using FEM or BEM, pre_ and post_processor is necessary pre_ and post_processor and analyzer use same structural model. But many other tasks related to structural design, such as optimization, design of layout, etc, do not share that model in spite of their resemblance of requiring data. So, a pre_ and post_ processor was developed using a relational database managing system. Developed system uses the DBMS as a data storage and interacts with it using SQL interface. In this way, many other tasks that uses same structural data can be developed.

  • PDF

KSTAR Superconducting Magnet Supporting Post Prototype Manufacturing and Structural Load Test (KSTAR 초전도자석 지지각 시작품재작 및 구조시험)

  • 허남일;이영신
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.45-49
    • /
    • 2001
  • A magnet supporting post installed between the lower TF coil tooled by 4.5 K supercritical helium and the cryostat base is one of the most important components of the superconducting magnet supporting structure for KSTAR Tokamak. This structure should be flexible to absorb thermal shrink of the magnet and also should be rigid to support the magnet weight and the Plasma disruptions load. The Post was designed with stainless steel 316LN and CFRP that have low thermal conductivity and high structural strength at low temperature. In order to verify the possibility of fabrication and the structural safety. a whole scale prototype of the KSTAR magnet supporting post was manufactured and tested. Static and compressive cyclic load tests under the maximum Plasma vertical disruption load and the magnet dead weight were performed. The teat results showed that the magnet supporting post of KSTAR Tokamak was possible to manufacture and structurally rigid.

  • PDF

Optimal Active Control of Bridges using Modified King-post Mechanism (수정된 King-post mechanism을 이용한 교량 구조물의 최적능동제어)

  • 김준형;정길호;이인원
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.10a
    • /
    • pp.103-110
    • /
    • 1995
  • This Paper develops a new control system to reduce the vibration of bridges using King-post mechanism. The optimal active control theory is used in the control system. The positions of post and roller in the King-post mechanism are important factors, since the vibration of bridges is very sensitive to their variations. To demonstrate the efficiency of the proposed control mechanism, a simply supported beam under moving load is considered.

  • PDF

Object-Oriented Models for Integrated Processing System of Finite Element Structural Analysis Program (유한요소 구조해석 프로그램의 전후처리 통합 운영 시스템을 위한 객체지향적 모델)

  • 서진국;송준엽;신영식;권영봉
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1994.10a
    • /
    • pp.17-24
    • /
    • 1994
  • The pre- and post-processor for finite element structural analysis considering the user-friendly device are developed by using GUI. These can be used on WINDOWS' environment which is realized the multi-tasking and the concurrency by object-oriented paradigm. They are designed to control integratedly the pre-processing, execution and the post-processing of the finite element structural analysis program on multiple windows. These object-oriented modeling approach can be used for complex integrated engineering systems.

  • PDF

Buckling of post-tensioned composite beams

  • Bradford, M.A.
    • Structural Engineering and Mechanics
    • /
    • v.2 no.1
    • /
    • pp.113-123
    • /
    • 1994
  • A method for computing the elastic buckling prestressing force of a post-tensioned composite steel-concrete tee-beam is presented. The method is based on a virtual work formulation, and incorporates the restraint provided by the concrete slab to the buckling displacements of the steel beam. The distortional buckling solutions are shown to be given by a quadratic equation. The application of the analysis to calculation buckling strengths is given, based on codified rules for beam-columns. Conclusions are then drawn on the importance of distortional buckling when a post-tensioned composite beam is stressed during jacking.

Shear Performance of Hybrid Post and Beam Wall System Infilled with Structural Insulation Panel (SIP)

  • Shim, Kug-Bo;Hwang, Kweon-Hwan;Park, Joo-Saeng;Park, Moon-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.5
    • /
    • pp.405-413
    • /
    • 2010
  • A hybrid post and beam shear wall system with structural insulation panel (SIP) infill was developed as a part of a green home 'Han-green' project through post and beam construction for contemporary life style. This project is on-going at the Korea Forest Research Institute to develop a new building system which improves Korean traditional wet-type building system and stimulates industrialized wood construction practice with pre-cut system. Compared to the traditional wet-type infill wall components, the hybrid wall system has benefits, such as, higher structural capacity, better thermal insulation performance, and shorter construction term due to the dry-type construction. To build up the hybrid wall system, in previous, SIP infill wall components can be manufactured at factory, and then inserted and nailed with helically threaded nails into the post and beam members at site. Shear performance of the hybrid wall system was evaluated through horizontal shear tests. The SIP hybrid wall system showed higher maximum shear strength, initial stiffness, ductility, yield strength, specified strength, and the specified allowable strength than those of post and beam with light-frame wall system. In addition to this, the hybrid wall system can provide speedy construction and structural and functional advantages including energy efficiency in the building system.