DOI QR코드

DOI QR Code

Shear Performance of Hybrid Post and Beam Wall System Infilled with Structural Insulation Panel (SIP)

  • Shim, Kug-Bo (Div. of Wood Engineering, Dept. of Forest Resources Utilization, Korea Forest Research Institute) ;
  • Hwang, Kweon-Hwan (Div. of Wood Engineering, Dept. of Forest Resources Utilization, Korea Forest Research Institute) ;
  • Park, Joo-Saeng (Div. of Wood Engineering, Dept. of Forest Resources Utilization, Korea Forest Research Institute) ;
  • Park, Moon-Jae (Div. of Wood Engineering, Dept. of Forest Resources Utilization, Korea Forest Research Institute)
  • Received : 2010.07.09
  • Accepted : 2010.08.30
  • Published : 2010.09.25

Abstract

A hybrid post and beam shear wall system with structural insulation panel (SIP) infill was developed as a part of a green home 'Han-green' project through post and beam construction for contemporary life style. This project is on-going at the Korea Forest Research Institute to develop a new building system which improves Korean traditional wet-type building system and stimulates industrialized wood construction practice with pre-cut system. Compared to the traditional wet-type infill wall components, the hybrid wall system has benefits, such as, higher structural capacity, better thermal insulation performance, and shorter construction term due to the dry-type construction. To build up the hybrid wall system, in previous, SIP infill wall components can be manufactured at factory, and then inserted and nailed with helically threaded nails into the post and beam members at site. Shear performance of the hybrid wall system was evaluated through horizontal shear tests. The SIP hybrid wall system showed higher maximum shear strength, initial stiffness, ductility, yield strength, specified strength, and the specified allowable strength than those of post and beam with light-frame wall system. In addition to this, the hybrid wall system can provide speedy construction and structural and functional advantages including energy efficiency in the building system.

Keywords

References

  1. Hwang, K., J. Park, and M. Park. 2007. Shear performance of post and beam construction by pre-cut process. Mokchae Konghak 35(6): 1-12.
  2. Komatsu, K., S. Takino, K. Hwang, T. Mori, and Y. Kataoka. 2004. Lateral shear performance of the wooden post & beam structure with prefabricated small mud shear walls. Proceedings of the 8th World Conference on Timber Engineering (WCTE2004): 159-164.
  3. KS 2005. Structural glued laminated timber. KS F 3021, Korean Standards Association.
  4. KS 2001. Method of shear (racking) resistance test for light-frame wood shear walls. KS F 2154, Korean Standards Association.
  5. American Society for Testing and Materials. 2001. Standard Practice for Static Load Test for Shear Resistance of Framed Walls for Buildings. ASTM E 564-00.
  6. International Organization for Standardization. 2003. Timber structures - Joints made with mechanical fasteners - Quasi-static reversed-cyclic test method. ISO 16670.
  7. Architectural Institute of Japan. 2002. New estimation method for shear wall performance. Standard for Structural Design of Timber Structure.
  8. Jang, S. 2002. Effects of stud spacing, sheathing material and aspect-ratio on racking resistance of shear walls. Mokchae Konghak 30(3): 97-103.