• 제목/요약/키워드: Post structures

검색결과 935건 처리시간 0.024초

Bending characteristics of Prestressed High Strength Concrete (PHC) spun pile measured using distributed optical fibre strain sensor

  • Mohamad, Hisham;Tee, Bun Pin;Chong, Mun Fai;Lee, Siew Cheng;Chaiyasarn, Krisada
    • Smart Structures and Systems
    • /
    • 제29권2호
    • /
    • pp.267-278
    • /
    • 2022
  • Pre-stressed concrete circular spun piles are widely used in various infrastructure projects around the world and offer an economical deep foundation system with consistent and superior quality compared to cast in-situ and other concrete piles. Conventional methods for measuring the lateral response of piles have been limited to conventional instrumentation, such as electrical based gauges and pressure transducers. The problem with existing technology is that the sensors are not able to assist in recording the lateral stiffness changes of the pile which varies along the length depending on the distribution of the flexural moments and appearance of tensile cracks. This paper describes a full-scale bending test of a 1-m diameter spun pile of 30 m long and instrumented using advanced fibre optic distributed sensor, known as Brillouin Optical Time Domain Analysis (BOTDA). Optical fibre sensors were embedded inside the concrete during the manufacturing stage and attached on the concrete surface in order to measure the pile's full-length flexural behaviour under the prescribed serviceability and ultimate limit state. The relationship between moments-deflections and bending moments-curvatures are examined with respect to the lateral forces. Tensile cracks were measured and compared with the peak strains observed from BOTDA data which corroborated very well. By analysing the moment-curvature response of the pile, the structure can be represented by two bending stiffness parameters, namely the pre-yield (EI) and post-yield (EIcr), where the cracks reduce the stiffness property by 89%. The pile deflection profile can be attained from optical fibre data through closed-form solutions, which generally matched with the displacements recorded by Linear Voltage Displacement Transducers (LVDTs).

부자 추출물이 LPS로 유도된 C57BL6 마우스의 패혈증 연관 급성 폐 손상에 미치는 영향 (Effect of Water Extract of Aconiti Lateralis Preparata Radix on Lung Injury in LPS-induced Septic C57BL6 Mice)

  • 이인승;부민아;심재욱;백승호;박진봉
    • 대한융합한의학회지
    • /
    • 제4권1호
    • /
    • pp.19-27
    • /
    • 2022
  • Objectives: TSepsis and subsequent acute lung injury (ALI) is a critical state of health caused by infection or endotoxins. This study was conducted to evaluate the effect of Water Extract of Aconiti Lateralis Preparata Radix (AR) on lipopolysaccharide (LPS)-induced sepsis in C57BL/6 mice. Methods: Male C57BL/6 mice were intraperitoneally injected with LPS to induce sepsis and ALI. AR was orally fed twice at 30 min and 180 min after LPS injection. At 24 h post injection, mice were sacrificed, bronchoalveolar lavage fluid (BALF) and blood was collected, and lung tissue was harvested. Hematoxylin and eosin staining was performed in lung tissues, wet/dry ratio of the lung tissue was measured, and the serum cytokine and chemokine levels were analyzed. Results: AR revoked the LPS-induced pathological changes in lung tissues, such as abnormal histological structures, immune cell infiltration and lung edema. Also, AR suppressed the neutrophil infiltration into the lung which was greatly increased by LPS injection based on the cell content of collected BALF. Serum cytokines and chemokines were measured, and AR reversed the LPS-induced increase of cytokines such as interleukin 1 beta, interleukin 6, tumor necrosis factor alpha and chemokines including C-X-C motif chemokine ligand 1 and 2. Conclusion: TAR showed a protective effect in the pathological progress of LPS-induced ALI. Especially, AR suppressed lung edema and infiltration of neutrophils by inhibiting cytokine and chemokine expressions. Such results demonstrate the potential of AR as a therapeutic agent for sepsis and sepsis-induced ALI.

Twin models for high-resolution visual inspections

  • Seyedomid Sajedi;Kareem A. Eltouny;Xiao Liang
    • Smart Structures and Systems
    • /
    • 제31권4호
    • /
    • pp.351-363
    • /
    • 2023
  • Visual structural inspections are an inseparable part of post-earthquake damage assessments. With unmanned aerial vehicles (UAVs) establishing a new frontier in visual inspections, there are major computational challenges in processing the collected massive amounts of high-resolution visual data. We propose twin deep learning models that can provide accurate high-resolution structural components and damage segmentation masks efficiently. The traditional approach to cope with high memory computational demands is to either uniformly downsample the raw images at the price of losing fine local details or cropping smaller parts of the images leading to a loss of global contextual information. Therefore, our twin models comprising Trainable Resizing for high-resolution Segmentation Network (TRS-Net) and DmgFormer approaches the global and local semantics from different perspectives. TRS-Net is a compound, high-resolution segmentation architecture equipped with learnable downsampler and upsampler modules to minimize information loss for optimal performance and efficiency. DmgFormer utilizes a transformer backbone and a convolutional decoder head with skip connections on a grid of crops aiming for high precision learning without downsizing. An augmented inference technique is used to boost performance further and reduce the possible loss of context due to grid cropping. Comprehensive experiments have been performed on the 3D physics-based graphics models (PBGMs) synthetic environments in the QuakeCity dataset. The proposed framework is evaluated using several metrics on three segmentation tasks: component type, component damage state, and global damage (crack, rebar, spalling). The models were developed as part of the 2nd International Competition for Structural Health Monitoring.

도시인프라 구조물 건전성 통합 모니터링 시스템 (Integrated Health Monitoring System for Infra-Structure)

  • 주승환;서희석;이승재;김민수
    • 한국시뮬레이션학회논문지
    • /
    • 제19권2호
    • /
    • pp.147-155
    • /
    • 2010
  • 우리나라를 둘러싼 동북아시아를 비롯하여 동남아시아의 도시에 이르기까지 지진, 태풍, 쓰나미 등의 환경재해가 빈발하고 있는 상황이다. 또한 최근 아이티, 칠레에서의 지진 발생뿐만 아니라 국내 수도권에서도 지진이 발생하여 자연재해에 대한 우려가 많아지고 있다. 현대의 건축물들은 다양한 자연재해로부터 취약할 수밖에 없으므로, 이를 최대한 빠르게 확인하여 경보하는 것만이 인명 및 재산의 피해를 최소화할 수 있는 방법이다. 본 연구에서는 구조물 건전성 진단을 위한 통합 모니터링 시스템에 대하여 소개한다. 통합모니터링 시스템을 웹페이지로 제작함으로써, 관리자는 인터넷이 되는 어디에서나 실시간으로 구조물의 상태를 확인할 수 있으며, PDA나 스마트폰과 같은 모바일 기기를 활용하여 실시간으로 통합 모니터링 시스템에 접근하여, 해당 구조물의 상태를 확인함으로써 피해 상황을 파악한다. 시설물 유지 관리자에게 건전성 유무를 판단할 자료를 실시간으로 제공하는 것은 조기대응으로 인한 현재의 피해를 최소화할 수 있으며, 추후 발생할 수 있는 추가적인 피해를 예방할 수 있는 장점이 있다.

Study of using the loss rate of bolt pretension as a damage predictor for steel connections

  • Chui-Hsin Chen;Chi-Ming Lai;Ker-Chun Lin;Sheng-Jhih Jhuang;Heui-Yung Chang
    • Earthquakes and Structures
    • /
    • 제24권2호
    • /
    • pp.81-90
    • /
    • 2023
  • The maximum drifts are important to the seismic evaluation of steel buildings and connections, but the information can hardly be obtained from the post-earthquake field investigation. This research studies the feasibility of using the loss rate of bolt pretension as an earthquake damage predictor. Full-scale tests were made on four steel connections using bolted-web-welded-flange details. One connection was unreinforced (UN), another was reinforced with double shear plates (DS), and the other two used reduced beam sections (RBS). The preinstalled strain gauges were used to control the pretensions and monitor the losses of the high-strength bolts. The results showed that the loss rate of bolt pretension was highly related to the damage of the connections. The pretensions lost up to 10% in all the connections at the yield drifts of 0.5% to 1%. After yielding of the connections, the pretensions lost significantly until fracture occurred. The UN and DS connections failed with a maximum drift of 4 %, and the two RBS connections showed better ductility and failed with a maximum drift of 6%. Under the far-field-type loading protocol, the loss rate grew to 60%. On the contrary, the rate for the specimen under near-fault-type loading protocol was about 40%. The loss rate of bolt pretension is therefore recommended to use as an earthquake damage predictor. Additionally, the 10% and 40% loss rates are recommended to predict the limit states of connection yielding and maximum strength, respectively, and to define the performance levels of serviceability and life-safety for the buildings.

Numerical investigation on seismic behaviors of midrise special moment resistant frame retrofitted by timber-base bracings

  • Ainullah-Mirzazadah, Ainullah-Mirzazadah;Sabbagh-Yazdi, Saeed-Reza
    • Steel and Composite Structures
    • /
    • 제45권1호
    • /
    • pp.83-100
    • /
    • 2022
  • Timber is one of the few natural, renewable building materials and glulam is a type of engineering wood product. In the present work, timber-based braces are applied for retrofitting midrise Special Moment Resisting Frame (SMRF) using two types of timber base braces (Timber base glulam, and hybrid Timber-Steel-BRB) as alternatives for retrofitting by traditional steel bracings. The improving effects of adding the bracings to the SMRF on seismic characteristics of the frame are evaluated using load-bearing capacity, energy dissipation, and story drifts of the frame. For evaluating the retrofitting effects on the seismic performance of SMRF, a five-story SMRF is considered unretofitted and retrofitted with steel-hollow structural section (HSS) brace, Glued Laminated Timber (Glulam) brace, and hybrid Timber-Steel BRB. Using OpenSees structural analyzer, the performance are investigated under pushover, cyclic, and incremental loading. Results showed that steel-HSS, timber base Glulam, and hybrid timber-steel BRB braces have more significant roles in energy dissipation, increasing stiffness, changing capacity curves, reducing inter-story drifts, and reducing the weight of the frames, compared by steel bracing. Results showed that Hybrid BRB counteract the negative post-yield stiffness, so their use is more beneficial on buildings where P-Delta effects are more critical. It is found that the repair costs of the buildings with hybrid BRB will be less due to lower residual drifts. As a result, timber steel-BRB has the best energy dissipation and seismic performance due to symmetrical and stable hysteresis curves of buckling restrained braces that can experience the same capacities in tension and compression.

A Prototype of Distributed Simulation for Facility Restoration Operation Analysis through Incorporation of Immediate Damage Assessment

  • Hwang, Sungjoo;Choi, MinJi;Starbuck, Richmond;Lee, SangHyun;Park, Moonseo
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.339-343
    • /
    • 2015
  • To rapidly recover ceased functionality of a facility after a catastrophic seismic event, critical decisions on facility repair works are made within a limited period of time. However, prolonged damage assessment of facilities, due to massive damage in the surrounding region and the complicated damage judgment procedures, may impede restoration planning. To assist reliable structural damage estimation without a deep knowledge and rapid interactive analysis among facility damage and restoration operations during the approximate restoration project planning phase, we developed a prototype of distributed facility restoration simulations through the use of high-level architecture (HLA) (IEEE 1516). The simulation prototype, in which three different simulations (including a seismic data retrieval technique, a structural response simulator, and a restoration simulation module) interact with each other, enables immediate damage estimation by promptly detecting earthquake intensity and the restoration operation analysis according to estimated damage. By conducting case simulations and experiments, research outcomes provide key insights into post-disaster restoration planning, including the extent to which facility damage varies according to disaster severity, facility location, and structures. Additional insights arise regarding the extent to which different facility damage patterns impact a project's performance, especially when facility damage is hard to estimate by observation. In particular, an understanding of required type and amount of repair activities (e.g., demolition works, structural reinforcement, frame installation, or finishing works) is expected to support project managers in approximate work scheduling or resource procurement plans.

  • PDF

Effect of varying amounts of linseed oil or saturated fatty acids around insemination on reproductive and blood parameters of ewes

  • Hamed Esmaili;Mohsen Eslami;Hamed Khalilvandi-Behrozyar;Farhad Farrokhi-Ardabili
    • Journal of Animal Science and Technology
    • /
    • 제65권5호
    • /
    • pp.922-938
    • /
    • 2023
  • The current study was designed to evaluate the effect of sequential low and high dietary linseed oil (LO; as omega-3 enriched fatty acid; FA) before and post insemination, respectively, on different plasma variables of ewes. Fat-tailed Qezel ewes were assigned randomly to be fed a diet enriched with 3% LO (n = 30) or the saturated FA (SFA; n = 30) three weeks before insemination (Day 0). The lipogenic diet supplemented with 6% LO or SFA was fed after insemination until Day +21. The control ewes were fed an isocaloric and isonitrogenous diet with no additional FA during the study. Estrus was synchronized by inserting a vaginal sponge (Spongavet®) for 12 days + 500 IU equine chorionic gonadotropin (eCG; Gonaser®), and ewes were inseminated via laparoscopic approach 56-59 h after eCG injection. The size of ovarian structures was assessed by transvaginal ultrasonography at -21, -14, -2, 0, and +10 days. Blood samples were collected weekly to measure the plasma's different biochemical variables and FA profile. Treatment did not affect the amounts of glucose, aspartate aminotransferase, alanine aminotransferase, lactate dehydrogenase, interleukin-10, interleukin-2, and non-esterified FA (p > 0.05). Conversely, concentrations of triglyceride, cholesterol, tumor necrosis factor-alpha, and insulin-like growth factor-1 were higher in SFA-fed ewes relative to control animals (p < 0.05). LO feeding resulted in greater amounts of n-3 FA isomers in plasma, while higher amounts of stearic acid were detected in SFA fed group 0 and +21 (p < 0.05). The number of ovarian follicles and corpora lutea also were not affected by treatment. Other reproductive variables were not affected by treatment except for the reproductive rate. It seems that LO or SFA feeding of fat-tailed ewes peri-insemination period was not superior to the isocaloric non-additional fat diet provided for the control group during the non-breeding season.

데이터 스케일링과 분할 방식에 따른 예측모델의 영향 분석 - 그라운드 앵커가 설치된 흙막이 벽체 대상 (Analysis of the Impact on Prediction Models Based on Data Scaling and Data Splitting Methods - For Retaining Walls with Ground Anchors Installed)

  • 신준우;한희수
    • 지질공학
    • /
    • 제33권4호
    • /
    • pp.639-655
    • /
    • 2023
  • 최근 지하공간에 대한 수요가 많아지면서 대심도 굴착으로 흙막이 벽체가 활용되고 있다. 흙막이 벽체는 변위에 취약한 구조물로써 국토교통부에서 제시한 관리기준으로 계측관리를 수행하고 있으나 계측관리를 통한 대비는 후처리에 가깝다고 할 수 있다. 따라서 본 연구에서는 머신러닝을 이용한 그라운드 앵커가 설치된 흙막이 벽체의 수평변위 예측뿐만 아니라 머신러닝으로 계측데이터를 학습하는 과정에서 데이터 스케일링과 분할 방법에 따른 예측모델의 영향을 분석하였다. 이 연구의 분석결과에 따르면 사용자 지정분할방법이 적합하지 않은 경우도 있었으나 일정 조건하에서 데이터 학습 및 출력에 가장 우수한 성능을 나타냈다. 데이터 스케일링은 앵커의 인장력, 수압을 표준화하였을 때 오차 1 이내, R-Squared 값이 0.77로 우수한 성능을 나타냈으며 스케일링을 적용하지 않은 모델 대비 음의 변위를 예측하는 결과를 보였다.

Experimental study on replaceable precast concrete beam-column connections

  • Seung-Ho Choi;Sang-Hoon Lee;Jae-Hyun Kim;Inwook Heo;Hoseong Jeong;Kang Su Kim
    • Earthquakes and Structures
    • /
    • 제26권1호
    • /
    • pp.49-58
    • /
    • 2024
  • The purpose of this study was to develop a system capable of restoring the seismic performance of a precast concrete (PC) connection damaged by an earthquake. The developed PC connection consists of a top-and-seat angle, post-tensioning (PT) tendons, and U-shaped steel. The PC beam can be replaced by cutting the PT tendons in the event of damage. In addition, the seismic performance of the developed PC beam-column connection was evaluated experimentally. A PC beam-column connection specimen was fabricated, and a quasistatic cyclic loading test was conducted to a maximum drift ratio of 2.3%. Subsequently, the PC beam was replaced by a new PC beam, and the repaired PC connection was loaded to a maximum drift ratio of 5.1%. The structural performance of the repaired PC connection was then compared with that of the original PC connection. The difference in the load at the drift ratio of 2.3% between the original and the repaired PC specimens was only 0.2%. The residual drift ratio in the repaired PC specimen did not exceed 1.0% at the 2.0 % drift ratio cycles, which satisfies the life safety performance level specified in ACI 374.2R-13. When the developed PC connection system is used, structural performance can be restored by rapidly replacing the damaged elements.