불평등전장에서 $SF_6/CO_2$ 혼합기체의 뇌임펄스 전구방전특성 (Characteristics of lightning impulse preliminary breakdown discharge under non-uniform electric field in $SF_6/CO_2$ mixtures)

  • 이복희;오성균;백영환;안창환;전덕규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2140-2142
    • /
    • 2005
  • This paper presents the experimental results on the preliminary breakdown characteristics under a highly non-uniform electric field in $SF_6/CO_2$ gas mixtures. The impulse preliminary breakdown developments are investigated by the measurements of corona current and light emission images. As a result, the preliminary breakdown development mechanisms for both positive and negative polarities are same. The first streamer corona is initiated at the tip of needle electrode, and the leaders develop with a stepwise propagation and bridge the test gap. The pause time of leader pulses in the positive polarity is significantly shorter than that in the negative polarity. Also, the time interval between the first streamer corona onset and breakdown in the negative polarity was much longer than that in the positive polarity The discharge channel paths in the positive polarity were zigzag. On the other hands, the leader channel in the negative polarity was thicker than that in the positive polarity.

  • PDF

SF6/CO2혼합기체 중에서 뇌임펄스코로나방전의 특성 (Characteristics of lightning Impulse Corona Discharges in SF6/CO2 Mixtures)

  • 이복희;백영환;오성균;안창환
    • 조명전기설비학회논문지
    • /
    • 제20권1호
    • /
    • pp.85-90
    • /
    • 2006
  • 본 논문은 불평등 전계의 $SF_6/CO_2$혼합기체 중에서 전구방전특성에 대한 실험결과를 제시한다. 임펄스 전구방전 진전을 코로나 전류와 방전광 이미지의 측정으로 조사하였다. 정 부극성의 전구방전 진전메커니즘은 기본적으로 같았으며, 초기스트리머코로나는 침전극의 끝단에서 발단되어 계단상으로 진전하는 리더에 의해 시험갭을 교락시킨다. 정극성에서 리더펄스의 휴지시간은 부극성에서보다 매우 짧았다. 또한 부극성에서 초기스트리머코로나와 절연파괴사이의 시간간격은 정극성에서보다 매우 길게 나타났다. 정극성에서 방전채널경로는 임의적으로 나타났으며, 부극성에서 리더 채널은 정극성에서 보다 굵고 밝게 나타났다.

HVDC용 LSR/Nano Silica Composites의 IPT특성 연구 (Study on IPT Characteristics of LSR / Nano Silica Composites for HVDC)

  • 박재준
    • 전기학회논문지
    • /
    • 제68권1호
    • /
    • pp.61-68
    • /
    • 2019
  • Only the power is converted from AC to DC, in accordance with IEC 60587 based test method, in order to develop the LSR(Liquid Silicone Rubber) insulator material for HVDC, the experiment of Inclined Plate Tracking and Erosion Resistance was conducted. A contaminant (2.5 mS/cm: ammonium chloride) was applied at a rate of 0.3 ml/min and a voltage of ${\pm}3.5kV$, and was evaluated on the basis of 60 mA/2s. The samples were prepared by dispersing LSR/Nano silica_25wt% Composites in LSR. The erosion phenomena of surface discharge and tracking due to DC polarity and negative polarity were measured by image, leakage current maximum and thermal camera. The thermal imaging camera measured the surface temperature generated by the joule heat of the leakage current due to the drying discharge and the conductive current. After the measurement, the tracking and erosion mechanisms were evaluated for erosion weight, erosion depth and erosion length. Positive and negative polarity of LSR/Nano Silica_25wt% composite Tracking and erosion results show that positive polarity is more severe than negative polarity.

온도변화에 따른 $SF_6$ 가스의 절연특성 (Characteristics of Dielectries in $SF_6$ Accoding to a change in Temperature)

  • 이복희;김회구;박건훈;이규선;김동성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1436-1437
    • /
    • 2007
  • This paper presents the experimental results of the dielectric characteristics with temperature changes under highly non-uniform electric field in $SF_6$ gas. The impulse preliminary breakdown developments were investigated by the measurement of predischarge current and breakdown voltage. As a result, the first stremer corona is initiated at the tip of needle electrode, and bridges the test gap. Also the first stremer corona onset and breakdown voltages the negative polarity was much higher than that in the positive polarity in same temperature. In addition, the varition of temperature have a little effect on the positive polarity. On the other hand, in some cases negative polarity corona onset and breakdown voltages increased with increasing a high temperature.

  • PDF

균등전계 중에 놓인 침상 전극의 끝단에서 발생한 직류 코로나방전 특성 (Characteristics of DC Corona Discharges Caused at the tip of a Needle-shaped Electrode Placed in the Homogeneous Electric Fields)

  • 김태기;김승민;이복희
    • 조명전기설비학회논문지
    • /
    • 제29권11호
    • /
    • pp.74-81
    • /
    • 2015
  • In the measurement of atmospheric static electric field, it is important to know characteristics of corona discharges caused at the tip of test electrode. This paper presents the fundamental data of DC corona discharges that occurred at the tip of a needle-shaped electrode placed in the homogeneous background electric field which simulates the atmospheric static field under thundercloud. The major characteristics of interest for this purpose are the polarity effect of corona discharges and the magnitudes and time intervals of corona current pulses. The experimental set-up consists of the plate-to-plate configuration with a needle-shaped protrusion, DC power supply, and voltage and current measuring devices. As a result of experiments, the polarity dependence of corona pulses is significantly pronounced. The time intervals between successive corona pulses in the negative polarity is much longer than those in the positive polarity. The time intervals for both polarities is drastically decreased as the applied electric field is increased. Also the magnitudes of the positive corona pulses are slightly changed with an increase in applied electric field, but those of the negative corona pulses are linearly increased with increasing the applied electric fields.

Defect Diagnosis of Cable Insulating Materials by Partial Discharge Statistical Analysis

  • Shin, Jong-Yeol;Park, Hee-Doo;Lee, Jong-Yong;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제11권1호
    • /
    • pp.42-47
    • /
    • 2010
  • Polymer insulating materials such as cross linked polyethylene (XLPE) are employed in electric cables used for extra high voltage. These materials can degrade due to chemical, mechanical and electric stress, possibly caused by voids, the presence of extrinsic materials and protrusions. Therefore, this study measured discharge patterns, discharge phase angle, quantity and occurrence frequency as well as changes in XLPE under different temperatures and applied voltages. To quantitatively analyze the irregular partial discharge patterns measured, the discharge patterns were examined using a statistical program. A three layer sample was fabricated, wherein the upper and lower layers were composed of non-void XLPE, while the middle layer was composed of an air void and copper particles. After heating to room temperature and $50^{\circ}C$ and $80^{\circ}C$ in silicone oil, partial discharge characteristics were studied by increasing the voltage from the inception voltage to the breakdown voltage. Partial discharge statistical analysis showed that when the K-means clustering was carried out at 9 kV to determine the void discharge characteristics, the amount discharged at low temperatures was small but when the temperature was increased to $80^{\circ}C$, the discharge amount increased to be 5.7 times more than that at room temperature because electric charge injection became easier. An analysis of the kurtosis and the skewness confirmed that positive and negative polarity had counterclockwise and clockwise clustering distribution, respectively. When 5 kV was applied to copper particles, the K-means was conducted as the temperature changed from $50^{\circ}C$ to $80^{\circ}C$. The amount of charge at a positive polarity increased 20.3% and the amount of charge at a negative polarity increased 54.9%. The clustering distribution of a positive polarity and negative polarity showed a straight line in the kurtosis and skewness analyses.

세라믹 복합체의 방전가공 특성 (Characteristics of Electrical Discharge Machining of Ceramic Composites)

  • 우정윤;왕덕현;윤존도;안영철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.46-50
    • /
    • 1996
  • Die sinking Electrical Discharge Machining(EDM) of TiC/Al$_2$O$_3$Ceramic Matrix Composite(CMC) was conducted for positive and negative polarity according to the change of current and Duty Factor(DF). Also FEM analysis about temperature distribution of workpiece by one spark was executed. Maximum surface roughness( R$_{max}$ ) and SEM photographs of the EDMed surface for different conditions were evaluated. Higher Material Removal Rate(MRR) was obtained for negative polarity than positive one. Better surface morphology was found as the current is decreased, but the MRR was also decreased. From the SEM photographs, the size of melt cavity due to one spark is about 100 to 150${\mu}{\textrm}{m}$ in diameterer

  • PDF

시각디스플레이에서 단어와 배경간의 밝기, 대비부호, 색상차이에 따른 가독성 및 감성효과 (The Impact of Brightness, Polarity, and Hue Difference on Legibility and Emotional Effect of Word in Visual Display)

  • 정혜헌;조경자;한광희
    • 인지과학
    • /
    • 제17권4호
    • /
    • pp.337-356
    • /
    • 2006
  • 본 연구에서는 시각디스플레이에서 단어와 배경간의 밝기, 대비부호, 색상 차이가 가독성 및 감성에 미치는 효과를 살펴보았다. 실험 1에서는 밝기차이(대, 중, 소)${\times}$대비부호(정적, 부적) 조건에 따른 가독성, 심미성, 선호도의 효과를 알아보았다. 실험 1의 결과, 밝기 차이가 커짐에 따라 가독성, 심미성, 선호도가 증가하였다. 실험 2에서는 실험 1 조건에 네 가지 색상 요인(초록, 빨강, 노랑, 파랑)을 추가하여 수행하였다. 그 결과 가독성에서는 밝기와 대비부호의 주효과, 밝기와 대비부호간의 상호작용효과가 유의미하였으며, 심미성과 선호도에서는 밝기, 대비부호, 색상의 주효과, 밝기와 색상간의 상호작용효과가 유의미하였다. 즉 밝기의 차이가 커짐에 따라 가독성, 심미성, 선호도가 증가하였으며, 정적대비가 부적대비에 비해 가독성, 심미성, 선호도가 더 좋았으며, 색상은 빨강, 파랑, 초록, 노랑 순으로 심미성과 선호도가 높은 결과를 보였다. 또한 가독성에서 밝기와 대비부호간의 상호작용효과는 밝기의 차이가 작은 조건에서 부적대비가 정적대비보다 반응시간이 길게 나타났기 때문인 것으로 보인다. 심미성과 선호도에서 밝기와 색상간의 상호작용효과가 나타난 것은 밝기 차이가 작은 조건에 비해 큰 조건에서 색상에 따른 심미성효과가 유의미하게 차이가 있었기 때문인 것으로 보인다. 실험 3에서는 텍스트 디자인과 단일색을 대상으로 18개의 감성 어휘를 평정하게 하여 감성의 유사성을 측정하였다. 그 결과, 특정 색이 지닌 주관적인 느낌이 텍스트 디자인에 잘 반영되기 위해서는 배경에 그 색을 사용하는 것이 더 적절하다는 결론을 얻었다.

  • PDF

플라즈마 처리한 고분자 복합재료의 표면특성변화 (Surface static properties in polymer hybrid material after plasma treatment)

  • 박종관
    • 전자공학회논문지 IE
    • /
    • 제44권3호
    • /
    • pp.6-11
    • /
    • 2007
  • 본 연구는 플라즈마 처리한 고분자 복합재료 표면의 접촉각, X-선광전자분광법(XPS) 및 코로나 대전에 의한 표면 정전특성을 분석하여 발생된 화학적 변화와 정전적 특성 변화를 고찰하여 열화 메커니즘을 도출하였다. 플라즈마 처리된 시료의 접촉각 및 표면전위는 표면에 카르복실기 라디칼을 포함하는 다량의 측쇄화가 집중적으로 발생되어 처리시간에 따라 급격한 친수화가 진행되었다. 플라즈마 처리로 인한 화학적 변화에서 표면에 carboxyl 라디칼이 주로 형성되면서 급격히 표면 친수화로 변화하였다. 정전변화를 분석한 전위감쇠 결과에서 미처리 시료는 부극성 표면을 나타내었으나, 친수화 표면은 carboxyl 라디칼(-COO*)을 포함하는 정극성 라디칼로 인해 정극성 표면으로 변화하여 부극성 전하가 빠르게 감소하였다.

플라즈마처리에 따른 에폭시 복합재료의 표면특성 (Surface Properties of Epoxy Composites by Plasma Treatment)

  • 임경범;이백수;이덕출
    • 한국전기전자재료학회논문지
    • /
    • 제14권10호
    • /
    • pp.821-827
    • /
    • 2001
  • In this study performed to identify a degradation mechanism in macromolecular insulating material, the contact angel, surface potential decay, surface resistivity, and XPS analysis were compared after exposure of FRP laminate to plasma discharge. In the case of contact angle, the surface of specimen untreated showed weak hydrophobic property of 73。. However, the contact angle was decreased to 20。in the plasma-treated specimen. In the case of chemical changes arising form plasma treatment, carboxl radicals were generated mainly in the surface treated, which was rapidly changed to the hydrophilic one. In the corona potential decay study to determine the electrical changes of the surface, positive charges were rapidly decreased when compared with negative charges, leading to negative property in the surface of specimen not treated. However, in the case of the hydrophilic surface, lots of carboxl radicals acting as positive polarity were generated, resulting in positive surface. Owing to such positive surface, charges of negative polarity applied were rapidly decreased.

  • PDF