• Title/Summary/Keyword: Positive·Negative polarity

Search Result 153, Processing Time 0.029 seconds

Space charge characteristics in several polymers at high temperature (고분자 재료의 고온하분포특성)

  • 남진호;고정우;서광석
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.84-87
    • /
    • 2001
  • Space charge formation at high temperature was investigated in several polymers using pulsed electro-acoustic (PEA) method. In SXLPE, homocharge is found and increased as an increase of temperature. In a charge of polarity of poling voltage(positive to negative), space charge mainly cause of hole injection. In Ionomer, heterocharge is found because of ion. As an increase of temperature heterocharge is also increased. In PET, As an increase of temperature homocharge is decreased.

  • PDF

DC Field Effect on Streaming Electrification in Insulating Oil (절연유의 유동대전특성에 미치는 직류전계의 영향에 관한 연구)

  • Chung, K.H.;Kim, Y.W.;Kim, D.S.;Hwang, L.H.;Lim, H.C.;Park, J.Y.;Kim, J.T.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1436-1437
    • /
    • 1998
  • In this paper, the result of experimental investigation into the streaming electrification phenomena of insulating oil under an external dc field effect is described. Energization by positive dc voltage enhanced the streaming electrification. but when the applied voltage was negative, the polarity of streaming current was field strength dependent.

  • PDF

Predischarge Phenomena in Nonuniform Fields Caused by Lightning Impulse Voltages in SF(sub)6-$N_2$Mixtures (SF(sub)6-$N_2$혼합가스중에 뇌임펄스전압에 의해 형성된 불평등전장에서의 전구방전현상)

  • 이복희;이경옥;백승권
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.6
    • /
    • pp.288-295
    • /
    • 2001
  • Predischarges in nonuniform electric field stressed by lightning impulse voltagesin SF(sub)6-$N_2$mixtures are initiated by streamer coronas. Due to field ehnancement at a protrusion point of electrodes new ionization processes occur and a precursor, which leads to a first leader, is created. The leader proceeds step by step to the opposite electrode and the final jump bridges the test gap. It was found that the predischarge is propagated with a leader mechanism of stepwise expansion from the predischarge current waveforms measured by a shunt. The predischarge current is closely related to the amplitude and polarity of applied voltages, the gas pressure and the gap geometry. The time intervals between step leaders for the positive and negative polarities were inversely proportional to V.P$^2$. When the gas pressure increases in the positive polarity, statistical time lag to statistical time lag to streamer corona inception increase slightly, but the formative time lag to flashover is significantly decreased.

  • PDF

Effect of High Voltage Pulsed Galvanic Current on Wound Healing in Rabbits (고압맥동 평류자극이 가토 상처치유에 미치는 영향)

  • Kim, Sik-Hyun;Park, Rae-Joon;Kwon, Hyuk-Cheol
    • Physical Therapy Korea
    • /
    • v.3 no.3
    • /
    • pp.67-81
    • /
    • 1996
  • This study was performed to assess the efficacy of high voltage pulsed galvanic current for the healing of wounds in rabbits. Skin wounds were created laterally on the flank of 12 domestic rabbits($3{\times}3cm$). The wounds of each group were treated with an intensity of 170 V at a frequency of 70 pulses per second, which was applied for 30 minutes a day for 10 days. The experimental groups were randomly assigned to either EXP I (n=3), EXP II(n=3), EXP III(n=3) or control(n=3). Each group was stimulated under the following conditions : 1) EXP I (Negative polarity), 2) EXP II (Change in polarity, negative electrode stimulation during the first 3 days and then positive electrode stimulation from 4 to 10 days), 3) EXP III(Positive polarity), 4) control(No stimulation). An active electrode was placed over the wound and a dispersive electrode on the buttock. The rate of wound closure was compared with the original wound size, evaluated by a tracing film in each measurement period. Finally, on the wound in each group, skin tissue was excised for histological evaluation after treatment for 10 days. The results obtained are as follows : 1) It was found that the control group did not show a complete remodeling of epitherial layer and had a chronic inflammatory response. Judging from the irregularity of intercellular space and the loose alignment of connective tissue, these findings show that wound healing was delayed. 2) EXP I showed a significant bactericidal effect, but a moderate response of vasodilation. The rate of wound closure was slower when compared with EXP II, III. 3) EXP II showed a complete remodeling of epitherial layer and a positive repair of connective tissue. Its rate of wound closure was best when compared with the others. 4) EXP III had a slower rate of wound closure than EXP II, but judging from the greater proliferation of collagen fibers and the dense alignment of connective tissue, this positive electrode was very effective in the formation of neo - connective tissue.

  • PDF

Impulse Breakdown Behaviors of Dry Air as an Alternative Insulation Gas for SF6

  • Li, Feng;Yoo, Yang-Woo;Kim, Dong-Kyu;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.3
    • /
    • pp.24-32
    • /
    • 2011
  • [ $SF_6$ ]gas, which has an excellent dielectric strength and interruption performance, is used in various applications such as gas insulated switchgear (GIS) in substations. However, since $SF_6$ has a high global warming potential (GWP), it is necessary to find an eco-friendly alternative insulation gas. In order to examine the possibility of using alternative insulation gases for $SF_6$ in power distribution system equipment, the dielectric strength and physical phenomena of dry air in a quasi-uniform electric field are investigated experimentally in this paper. As a result, the breakdown voltages for positive polarity are higher than those for negative polarity under impulse voltage applications. The negative 50[%] flashover voltage, $V_{50}$ of dry air under conditions above 0.4[MPa] gas pressure, is higher than 150[kV], that is the basic impulse insulation level of distribution equipment. The $V_{50}$ increases linearly with increasing the gas pressure, regardless of the waveform and polarity of the applied impulse voltages. The voltage-time curves are dependent on the rise time of the impulse voltage and gas pressure. Furthermore, streamer discharge was observed through light emission images by an ICCD camera under impulse voltage applications.

Characteristics by the Cloud-to-Ground Lightning Polarity Occurred over South Korea (남한 지역에서 발생한 구름-지면 낙뢰의 극성별 특성)

  • Myoung, Ji-Su;Suh, Myoung-Seok
    • Journal of the Korean earth science society
    • /
    • v.31 no.4
    • /
    • pp.335-347
    • /
    • 2010
  • The statistical characteristics of Cloud-to-Ground (CG) lightning data, observed by the total lightning detection system (TLDS) of KMA during the recent seven years (2002-2008), have been analyzed. Lightning frequency shows a strong interannual, seasonal and diurnal variations without regard to the polarity. The 74% and 0.6% of the total lightning occurred during the summer and winter, respectively. And it has a bimodal diurnal variation with two peaks (dawn: 0500-0700 LST, mid-afternoon: 1500-1600 LST). The ratio of positive flashes to negative ones also has a strong seasonal variation with the maximum and minimum during winter (62.5%) and summer (7.3%), respectively. Unlike the lightning frequency, the lightning intensity of negative flashes shows a weak interannual, seasonal and diurnal variations. However, the lightning intensity of positive flashes exhibits an inverse seasonal variation to that of lightning frequency, with the minimum and maximum during summer and winter, respectively. The lightning density is greatly higher in the western inland areas and the West/South Sea than in the eastern part and the East Sea. In general, the lightning intensity is stronger in the ocean, especially in the East Sea than in the inland area, regardless of the polarity.

V-t Characteristics in $SF_6-N_2$ Mixtures for Transient Impulse Voltages ($SF_6-N_2$ 혼합가스에서 과도임펄스전압에 대한 V-t특성)

  • Lee, Bok-Hui;Lee, Gyeong-Ok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.9
    • /
    • pp.456-465
    • /
    • 2001
  • In this paper, breakdown voltages in $SF_6-N_2$ mixtures were experimentally investigated to understand characteristics of dielectric strength and physical phenomena in nonuniform field disturbed by a needle shape protrusion. The test voltages are the lightning impulse$(\pm1.2/44 \mus)$ and the damped oscillatory impulse$(\pm400 ns / 0.83 MHz)$ voltages which can be occurred by the operation of disconnecting switches in gas-insulated switchgears(GIS). The effects of the polarity and wave shape of the test voltages, and the gas pressure on the V-t characteristics were in detail examined. The V-t characteristic curves were measured in different two ways : (1) one is the method by taking the maximum voltage recorded at or prior to breakdown against the time to breakdown, that is, the Procedures recommended in IEC 60060-1, (2) the other is the method by taking the voltage at the instant of chopping against the time to breakdown. As a result, the V-t characteristics of $SF_6-N_2$ mixtures in nonuniform electric field were significantly affected by the polarity and wave shape of the applied voltages. The positive breakdown voltages resulted in lower breakdown voltages in the time ranges considered, and the V-t curves for the negative oscillatory impulse voltage were extended over the longer time range. For the lightning impulse voltages, the V-t curves obtained by IEC Pub. 60060-1 were nearly same with the V-t curves obtained by the voltage at the instant of chopping against the time to breakdown. It is clear that the actual breakdown voltages were much lower than the maximum voltages appearing at or prior to breakdown because of the displacement current produced as a result of the dV/dt during the oscillatory transient voltage app1ication. The scattering of the negative actual breakdown voltages was much larger than that of the positive.

  • PDF

Dielectric Characteristics of N2 Gas under Impulse Voltage in a Quasi-Uniform Electric Field (준평등전계에서 임펄스전압에 대한 N2가스의 절연파괴특성)

  • Lee, Bok-Hee;Kim, Dong-Kyu;Li, Feng
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.126-132
    • /
    • 2010
  • This paper presents dielectric characteristics of $N_2$ gas under impulse voltages in a quasi-uniform electric field gap. The experiments were carried out at the test gap applied by the 1.2/50[${\mu}s$] lightning impulse voltage, 180/2500[${\mu}s$] switching impulse voltage, 500[ns]/1[MHz] very fast transient overvoltage(VFTO). The gap separation of sphere-to-plane electrodes was 14[mm] and the electric field utilization factor was about 71.2[%]. The gas pressure ranges from 0.2 to 0.6[MPa]. As a result, the electrical breakdowns are occurred by streamer discharge. Breakdown voltages are linearly increased with the gas pressure and the highest breakdown voltage is appeared under the VFTOs having fast rising time. Breakdown voltages under the positive impulse voltages were higher than those under the negative ones, and also the time to breakdown in the positive polarity is longer than that in the negative polarity.

Discharge Characteristics between Needle and Plane Electrodes in Water under Impulse Voltages (임펄스전압에 의한 침 대 평판전극에서 수중방전특성)

  • Choi, Jong-Hyuk;Park, Geon-Hun;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.8
    • /
    • pp.67-74
    • /
    • 2008
  • In this paper we describe discharge characteristics between needle-to-plane electrodes in water in various conditions such as different impulse voltages, polarities and water resistivities. Streamer corona is initiated at the tip of needle electrode and propagates toward plane electrode, and it experiences the final jump across the test gap. The branched channels of streamer coronas for lower water resistivities are much thicker and brighter than those for higher water resistivities at the same level of applied voltage. The negative streamer coronas not only have more branches but also widely spread out compared to the positive streamer coronas. A number of pulse-like currents ranging from some hundreds mA to a few A after streamer corona onset were produced with discharge developments. The time-lags-to breakdown for the positive polarity were remarkably shorter than those for the negative polarity. The pre-breakdown energy supplied into the test gap was inversely proportional to water resistivity.

Frequency of Solar Spotless Days and Flare Index as Indices of Solar Cycle Activity

  • Oh, Suyeon
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.2
    • /
    • pp.145-148
    • /
    • 2014
  • There was a research on the prolongation of solar cycle 23 by the solar cyclic variation of solar, interplanetary geomagnetic parameters by Oh & Kim (2013). They also suggested that the sunspot number cannot typically explain the variation of total solar irradiance any more. Instead of the sunspot number, a new index is introduced to explain the degree of solar activity. We have analyzed the frequency of sunspot appearance, the length of solar cycle, and the rise time to a solar maximum as the characteristics of solar cycle. Then, we have examined the predictability of solar activity by the characteristics of preceding solar cycle. We have also investigated the hemispheric variation of flare index for the periods that the leading sunspot has the same magnetic polarity. As a result, it was found that there was a good correlation between the length of preceding solar cycle and spotless days. When the length of preceding solar cycle gets longer, the spotless days increase. It is also shown that the shorter rise time to a solar maximum is highly correlated with the increase of sunspots at a solar maximum. Therefore, the appearance frequency of spotless days and the length of solar cycle are more significant than the general sunspot number as an index of declining solar activity. Additionally, the activity of flares leads in the northern hemisphere and is stronger in the hemisphere with leading sunspots in positive polarity than in the hemisphere with leading sunspots in negative polarity. This result suggests that it is necessary to analyze the magnetic polarity's effect on the flares and to interpret the period from the solar maximum to solar maximum as the definition of solar cycle.