• Title/Summary/Keyword: Position measurement

Search Result 2,295, Processing Time 0.028 seconds

Development of Precision Measuring Systems for Structural Deformation Measurements (구조물 변형관측을 위한 정밀측량시스템의 개발)

  • 김병국;최정민
    • Spatial Information Research
    • /
    • v.7 no.1
    • /
    • pp.63-79
    • /
    • 1999
  • In this research, the operational principle and the internal algorithm of theodolite measuring systems are studied and coded for a new software, and the feasibility of the laser system for the above mentioned usage is studied by simulation set-up of the system in the laboratory environment, and for the theodolite system modules for the communication between theodolite and computer is implemented, the data collection and storage, the simultaneous photogrammetric ' bundle ' adjustment for the theodolite position and the target points are coded, compiled and tested. for the simulation set-up of the laser system extensive studies on laser sources and laser detectors are performed, the system composition for the system simulation in the laboratory environment is studied and implemented, and the beam fluctuation due to the environmental changes in the course of the laser beam, such as changes in current of wind or in temperature is experimented. According to Experiment on the Source of 17 meters interval and the Detector, Laser beam is almost doesn't depend on air How, but it is effected by variations of temperature and light. Selecting cloudy day and time without change of temperature, it was realized that it is possible to perform deformation measurement more than approximately 2mm precision.precision.

  • PDF

ROENTGENOCEPHALOMETRIC STUDY FOR THE CHILDREN IN THE PRIMARY DENTITION OF KOREAN (한국인 유치열기 아동의 두부방사선 계측학적 연구)

  • Kim, Dong-Joon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.5 no.1
    • /
    • pp.64-75
    • /
    • 1978
  • In order to know cephalometric norms for the preschool children, this roentgeno cephalometric study was undertaken in each 50 Korean male and female children of primary dentition age from 4 to 5 year. The following results were obtained. 1. In the skeletal analysis, there was no significant difference between male and female in angular measurement and the linear measument of the male was generally greater than that of the female. 2. Saddle angle was $122.3^{\circ}$, articular angle was $147.6^{\circ}$, gonial angle was $119.4^{\circ}$ and the sum of each angle was $396.1^{\circ}$ in male and $396.6^{\circ}$ in female. 3. The ratio of mandibular body to anterior cranial base was about 1 : 0.91. 4. In the primary dentition, suggested that the nasion and point A move forward relative to sella turcica in a fashion, pogonion and point B are equal in angular position relative to plan S-N, bony chin and chin button was yet underdeveloped, and the forward growth of mandible was seen rapid than maxilla after 4 years. 5. Suggested that the percentage of anterior facial height to the posterior facial height were 64.4% in male and 64.1% in female. 6. Maxillary primary incisors was more upright than the permanent incisors, mandibular primary incisors was inclined lingually relative to the permanent incisor, and primary incisors was more upright than the permanent incisors. 7. Maxillary primary incisors in female was inclined labially than male. 8. In the the relationship of the upper lip and lower lip to the esthetic line, the upper lip was 2.11mm and the lower lip was 2.33mm front of the esthetic line.

  • PDF

Comparison of Upper and Lower Cervical Muscle Strengths Between Subjects With and Without Forward Head Posture

  • Eun, Ji-yeon;Kwon, Oh-yun;Hwang, Ui-jae;Jung, Sung-hoon;Ahn, Sun-hee
    • Physical Therapy Korea
    • /
    • v.27 no.4
    • /
    • pp.272-277
    • /
    • 2020
  • Background: Forward head posture (FHP) is common postural malalignment. FHP is described relatively extension to upper cervical and lower cervical is relatively flexion. Although several researchers mentioned the lower cervical flexion posture in FHP, most of the studies related to FHP is focused on the deep cervical flexor function. Objects: The purposes of present study is to compare the cervical strength (upper cervical extension [UCE], lower cervical extension [LCE], upper cervical flexion [UCF], lower cervical flexion [LCF]) between individuals with and without FHP. Methods: Fifty-one participants are recruited. Participants who have the craniovertebral angle (CVA) less than 48 degree were classified to the FHP group (n = 24) and the others were included in without FHP group (n = 27). The cervical strength (UCE, LCE, UCF, LCF) were measured using Smart KEMA strength sensor and the strength data was normalized by body weight. All strength measurement conducted at head and neck neutral position in sitting. Independent t-test was used to compare the cervical strength between individuals with and without FHP. Results: The mean value of CVA was greater in without FHP group than with FHP group (p < 0.000). The strength value of UCF (p < 0.002) and LCE (p < 0.001) was significant less in FHP group than without FHP group. But no significant differences were seen in the LCF and UCE strength between two groups. Conclusion: UCF and LCE weakness in FHP group should be considered to evaluate and manage the individuals with FHP.

Compensatory change of opposite hippocampus after temporal lobe surgery in patients with temporal lobe epilepsy Evidence from single-voxel proton MR spectroscopy

  • Lee, Sang-Hyun;Chang, Kee-Hyun;Chung, Chun-Kee;Song, In-Chan;Han, Moon-Hee
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.172-172
    • /
    • 2001
  • Purpose: To evaluate compensatory change of opposite hippocampus after temporal lobe surgery in th patient with temporal lobe epilepsy by using single-voxel proton MR spectroscopy. Method: Eighteen patients with intractable temporal lobe epilepsy (TLE) whose MR diagnos was unilateral hippocampal sclerosis (n=11) or localized unilateral anterior temporal lobe lesio (n=7) and who underwent anterior temporal lobectomy were included in the study. Singl proton MRS of opposite hippocampus was carried out on the same day or within 1 week af MR imaging before temporal lobe surgery and after over 1-year post-surgical follow-u Single voxel proton MRS were acquired using GE signa 1.5T scanner and spectrosco system (TR, 1500-2, 000: TE, 136-144). Region of interest (ROI) was placed in a simitar position for all examination to cover the medial temporal lobes including most of the head an body of hippocampus and a part of amygdala, the parahippocampal gyrus. The MR spectr were evaluated with a focus on the metabolite ratio of N-acetylaspartate (NAA choline-containing phospholipids (Cho), creatine (Cr). The metabolite ratios of NAA/ Cr were calculated from the relative peak height measurement. We evaluated change of th intensity ratio NAA/Cr between before and after surgery, to simplify quantification acro patients, because observed decreases in the ratio of NAA/Cr can be interpreted in terms o neuronal or axonal damage.

  • PDF

Comparison of Exposure dose according to the C-arm Angle Change (C-arm 각도 변화에 따른 피폭선량 비교)

  • Shin, Seong-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.9
    • /
    • pp.453-458
    • /
    • 2011
  • This study aimed to figure out the change of exposure dose to the radiologist according to the C-arm angle change. For the exam it was fixed with 101 kvp and 4.9mA for the exposure time with 3 seconds and 5 seconds respectively. C-arm Tube was located both under and over, then the average was taken after performing for 5 times with the change of angle from -30 degree to 0, 30, 60 and 90 degree. The detector measured in 160cm high from the position of the radiologist who operates the C-arm. The measurement was shown its highest result at -30 degree followed by 0, 30, 60, 90 from the highest order. Over tube method is higher than under tube method. Therefore, to reduce the exposure dose of the radiologist, it is required for using under tube method instead of over tube method. When the angle change is made, it is recommended to use the angle that tube is growing further apart from the radiologist. And it is also necessary to shorten exposed time as much as possible to create the same quality image and also to reduce the exposure dose.

Effect of Toruism Image on Tourism Motivation and Experientiality of Chinese Tourists' on Korean Wave (한류관광객의 관광동기 및 체험성이 관광 이미지에 미치는 영향)

  • Lee, Yk-Su
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.1
    • /
    • pp.387-395
    • /
    • 2011
  • This research the impacts of the tourism motivation and tourism product experimentiality to the korea national image and the results are as follow. First, chinese tourist' on korean wave showed sensory experiences of experiential marketing, emotional experience, cognitive experiences positively affect to the festival brand loyalty. Second, it showed all items of sensory experiences of experiential marketing, emotional experience, cognitive experiences positively affect to the festival brand loyalty. Through these results, first, Necessity is the possibility of knowing the thing there was grasp about tourism motive difference of the cold Chinese tourists' on korean wave. Second, there must be to cold current tourism goods development, must provide the possibility of knowing the thing was an experience characteristic to the tourists. With this character direction, presented a ongoing search that cold current korean wave tourism market measurement from governmental dimension, cold korean wave tourism goods development which applies the contents from enterprise dimension, theoretical foundation data triangular position from scientific dimension.

Coherent Analysis of vehicle HVAC Using the MDSA Method (다차원 해석법을 이용한 자동차 공조시스템의 기여도분석)

  • Oh Jae-Eung;Hwang DongKun;Abu Aminudin;Lee Jung-Youn;Kim SungSoo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.8 s.173
    • /
    • pp.143-150
    • /
    • 2005
  • To verify applicability of multi-dimensional spectral analysis (MDSA) fur noise source identification two different approaches which are frequency response and coherent function have been investigated. The coherence function approach appears able to separate the correlated system when the noise sources were coherent. In this study, we identify contribution of structure-borne-noise of vehicle HVAC system using MDSA method. Firstly, to identify the applicability of MDSA method, 4-inputs of vehicle HVAC system were the signals measured by accelerometers attached on the selected noise sources which were composed of blower, evaporator, heater and duct. While 1-output which was driver's position sound was the SPL signals measured by a remote microphone, when the blower motor was operating. We identify efficiency of systems modeled with four Inputs/single output through ordinary coherence function (OCF) and partial coherence function (PCF). As a result of experiment, the blower accounted for $62-88\%$ of the overall level of sound energy density. Also, according to the analysis of acoustic signal and vibration signals measurement, an investigation of the noise source identification in the vehicle HVAC is presented. With the sound intensity method, the major sources of the vehicle HVAC radiation are verified. Also the method of improving the noise reduction is proposed by attaching damping patch access to blower motor and noise reduction is verified.

Flow of a low concentration polyacrylamide fluid solution in a channel with a flat plate obstruction at the entry

  • Kabir, M.A.;Khan, M.M.K.;Rasul, M.G.
    • Korea-Australia Rheology Journal
    • /
    • v.16 no.2
    • /
    • pp.63-73
    • /
    • 2004
  • Flow in a channel with an obstruction at the entry can be reverse, stagnant or forward depending on the position of the obstruction. These flow phenomena have potential applications in the control of energy and various flows in process engineering. Parameters that affect this flow inside and around the test channel are the gap (g) between the obstruction geometry and the test channel, the Reynolds number (Re) and the length (L) of the test channel. The influence of these parameters on the flow behavior was investigated using a flat plate obstruction at the entry of the channel. A low concentration polyacrylamide solution (0.018% by weight) showing a powerlaw fluid behavior was used as the fluid in this investigation. The flow phenomena were investigated by the velocity measurement and the flow visualization and their results were compared with numerical simulation. These results of low concentration polyacrylamide solution are also compared with the results of water published elsewhere (Kabir et al., 2003). The maximum reverse flow inside the test channel observed was 20% - 30% of the outside test channel velocity at a g/w (gap to width) ratio of 1 for Reynolds numbers of 1000 to 3500. The influence of the test channel length (L) and the Reynolds number (Re) on the velocity ratio ($V_i$/$V_o$: inside velocity/outside velocity in the test channel) are also presented and discussed here.

Deformation Measurement of Well Thinning Elbow by Using Shearography (전단간섭법을 이용한 감육 곡관부의 변형 계측)

  • Jung, Hyun-Chul;Kim, Koung-Suk;Chang, Ho-Sub;Jung, Sung-Wook;Kang, Ki-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.5
    • /
    • pp.321-328
    • /
    • 2006
  • In this study, the deformation oi wall thinning elbow is measured and the position of the internal thinning defect is found out by shearography. Shearography is an optical method which has applied to nondestructive testing (NDT) and the strain/stress and deformation analysis. This technique has the merit of the directly measuring the first derivative of displacement with sensitivity which can be adjusted by handling the tilt mirror in the interferometer. In this paper, we tested carbon steel pipe locally wall thinned and loaded internal pressure and the shearography was applied to measure the out-of-plane deformation of wall thinning elbow and to investigate the internal thinning defect of it. From the results, it was confirmed that this technique is proper to the practical application on the pipe line system with internal defect.

Basic Study Measuring Cow Body Parameters and Adjusting Her Postures for an Robotic Milking System (로봇 착유기를 위한 젖소 체위측정 및 자세조정의 기초 연구)

  • Kwon, D.J.;Kim, W.;Lee, D.W.
    • Journal of Animal Environmental Science
    • /
    • v.8 no.3
    • /
    • pp.171-176
    • /
    • 2002
  • Physical parameters of milk cow were measured to design and build RMS(Robotic Milking System) with a tape-measurer and body parameter measurer. The parameters are very important variables to design an RMS. For the working zone space of an RMS manipulator and the movement blunting of milk cow, an interval frame was installed on the stall bottom, and then cow's behavioral reactions were tested. The results from this study is summarized as follow. 1. On the general physical condition measurement, the maximum, minimum and average body length of cow which is related to the space that the manipulator could work into the RMS were 175cm, 144cm, and 163cm respectively. It appeared that the average distance between bottom and chest was 60cm. 2. The average length between fore teats, fore and hind teats and hind teats were 178mm, 150mm and 95mm respectively. It appeared that the average length between bottom and teat attachments was 544mm, and the average length between fore teats and tail-end was 331mm. 3. Although a cow kept a some extent length between hind legs for milking, it looked a stable pose. However, the cow kept a some extent distance between front legs for milking, it looked a unstable pose. Based on results of this test, an interval frame of stall bottom should be installed around the position which was located at its hind legs.

  • PDF