• Title/Summary/Keyword: Position matching

Search Result 472, Processing Time 0.031 seconds

A Study of the Adjustment and Treatment Depending on the Change of Prostate Location Using DIPS in Proton Beam Therapy for Prostate Gland in which a Fiducial Gold Marker was Inserted (Fiducial Gold Marker가 삽입된 전립선암 양성자 치료 시 Digital Image Positioning System (DIPS)을 이용한 전립선의 위치변화에 따른 보정에 관한 연구)

  • Park, June-Ki;Kim, Sun-Young;Kim, Tae-Yoon;Choi, Kye-Sook;Yeom, Doo-Suk;Kang, Dong-Yoon;Choi, Seung-O;Park, Ji-Youn
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.25-29
    • /
    • 2008
  • Purpose: To monitor the changes of location of prostate gland using DIPS and to examine the adjustment and proton beam therapy depending on the movement of prostate gland in proton beam therapy for prostate gland in which a fiducial gold marker was inserted. Materials and Methods: This study was conducted in ten patients with prostate cancer who received proton beam therapy since April of 2008. To monitor the change of prostate location, three fiducial gold markers were inserted prior to the treatment. To minimize the movement of prostate gland, patients were recommended to urinate prior to the treatment, to intake a certain amount of water and to concomitantly undergo rectal balloon. In these patients, the set-up position was identical to that for a CT-simulation. The PA (posterior-anterior) and lateral images were obtained using both DIPS (digital image positioning system) and a plain radiography, and they were compared between the two imaging modalities. Thus, the changes of the location of fiducial gold marker were assessed based on three coordinates (x, y, z) and then adjusted. This was followed by proton beam therapy. Results: Images which were taken using a plain radiography were compared with those which were taken using DIPS. In ten patients, according to a reference bony marker, the mean changes of the location of fiducial gold marker based on an iso-center were X-axis: $\pm$0.116 cm, Y-axis: $\pm$0.19 cm and Z-axis: $\pm$0.176 cm. These ten patients showed a difference in the changes of location of prostate gland and it ranged between RT: 0.04 cm and RT: 0.24 cm on the X-axis; between Inf: 0.03 cm and Sup: 0.42 cm on the Y-axis; and Post: 0.05 cm and Ant: 0.35 cm on the Z-axis. Conclusion: To minimize the movement of prostate gland, as the pre-treatment prior to the treatment. In all the patients, however, three fiducial gold markers showed a daily variation which were inserted in the prostate gland. Based on the above data, Thus, the requirement of gold marker matching system depending on the daily variation in the proton beam therapy for which more accurate establishment of target was confirmed. It is assumed that an accurate effect of proton beam therapy would be enhanced by adjusting the target-center depending on the location change of prostate gland using DIPS which was used in the current study.

  • PDF

The Role of Air-Vacuum Cushion Device in Patients with Rectal Cancer in Radiation Therapy (직장암 환자에서 방사선치료시 Air-vacuum Cushion의 유용성)

  • Kim Ki-Hwan;Cho Moon-June;Kang No-Hyun;Kim Dong-Wuk;Kim Jun-Sang;Jang Ji-Young;Kim Jae-Sung
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.287-292
    • /
    • 2001
  • Prupose : We analyzed setup errors induced by using air-vacuum cushion as immobilization device in patients with rectal cancer. Materials and methods : We had treated the twenty patients with rectal cancer by 6 MV, 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at prone position. They were separated to two groups, control group, 10 patients using styrofoam, and test group, 10 patients using styrofoam and air-vacuum cushion. We measured errors of posterior field for x, y axis and lateral field for z, y axis with simulation film and EPID image using a matching technique. Results : In control group, the mean displacement values of pelvic bone landmark for x axis and y axis were 0.02 mm. 0.78 mm, respectively and the standard deviations of systematic error were 2.13 mm, 2.40 mm, respectively and the standard deviation of random error were 1.46 mm. 1.51 mm, respectively. In test group, the mean displacement values of x axis and y axis were -0.33 mm. 0.81 mm, respectively and the standard deviations of systematic error were 1.71 mm, 3.08 mm, respectively and the standard deviations of random errors were 1.40 mm. 1.88 mm, respectively. The mean displacement values of z axis and y axis were 2.98 mm. 0.74 mm, respectively and the standard deviations of systematic error were 4.75 mm, 2.65 mm, respectively and standard deviations of random error were 2.69 mm. 1.86 mm, respectively. The statistical difference of field size by using air vacuum cushion between two groups in posterior direction and lateral direction was not shown. Conclusion : We think that use of air-vacuum cushion may not be an advantage for improving setup accuracy in rectal cancer patients.

  • PDF

Automated patient set-up using intensity based image registration in proton therapy (양성자 치료 시 Intensity 기반의 영상 정합을 이용한 환자 자동화 Set up 적용 방법)

  • Jang, Hoon;Kim, Ho Sik;Choe, Seung Oh;Kim, Eun Suk;Jeong, Jong Hyi;Ahn, Sang Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.97-105
    • /
    • 2018
  • Purpose : Proton Therapy using Bragg-peak, because it has distinct characteristics in providing maximum dosage for tumor and minimal dosage for normal tissue, a medical imaging system that can quantify changes in patient position or treatment area is of paramount importance to the treatment of protons. The purpose of this research is to evaluate the usefulness of the algorithm by comparing the image matching through the set-up and in-house code through the existing dips program by producing a Matlab-based in-house registration code to determine the error value between dips and DRR to evaluate the accuracy of the existing treatment. Materials and Methods : Thirteen patients with brain tumors and head and neck cancer who received proton therapy were included in this study and used the DIPS Program System (Version 2.4.3, IBA, Belgium) for image comparison and the Eclipse Proton Planning System (Version 13.7, Varian, USA) for patient treatment planning. For Validation of the Registration method, a test image was artificially rotated and moved to match the existing image, and the initial set up image of DIPS program of existing set up process was image-matched with plan DRR, and the error value was obtained, and the usefulness of the algorithm was evaluated. Results : When the test image was moved 0.5, 1, and 10 cm in the left and right directions, the average error was 0.018 cm. When the test image was rotated counterclockwise by 1 and $10^{\circ}$, the error was $0.0011^{\circ}$. When the initial images of four patients were imaged, the mean error was 0.056, 0.044, and 0.053 cm in the order of x, y, and z, and 0.190 and $0.206^{\circ}$ in the order of rotation and pitch. When the final images of 13 patients were imaged, the mean differences were 0.062, 0.085, and 0.074 cm in the order of x, y, and z, and 0.120 cm as the vector value. Rotation and pitch were 0.171 and $0.174^{\circ}$, respectively. Conclusion : The Matlab-based In-house Registration code produced through this study showed accurate Image matching based on Intensity as well as the simple image as well as anatomical structure. Also, the Set-up error through the DIPS program of the existing treatment method showed a very slight difference, confirming the accuracy of the proton therapy. Future development of additional programs and future Intensity-based Matlab In-house code research will be necessary for future clinical applications.

  • PDF

The effect of orientation on recognizing object representation (규범적 표상의 방향성 효과)

  • Jung, Hyo-Sun;Lee, Seung-Bok;Jung, Woo-Hyun
    • Science of Emotion and Sensibility
    • /
    • v.11 no.4
    • /
    • pp.501-510
    • /
    • 2008
  • The purpose of this study was to investigate whether the orientation of the head position across different categories affect reaction time and accuracy of object recognition. Fifty four right handed undergraduate students were participated in the experiment. Participants performed the word-picture matching tasks, which were different in terms of head direction of object (i.e., Left-headed or Right-headed) and object category (i.e., natural : animal or artificial : tool). Participants were asked to decide whether each picture matched the word which was followed by the picture. For accuracy, no statistically significant difference was found for both animal and tool pictures due to the ceiling effect. Interaction effect of category and orientation were statistically significant, whereas only the main effect of category was significant. In the animal condition, faster reaction times were observed for left to right than right to left presentation, while no statistical significant difference was found in the tool condition. The orientation of the object's canonical representation was different across different categories. The faster RT for the animal condition implies that the canonical representation for animal is left-headed. This could be due to the orientation of the face.

  • PDF

Fast Sequential Bundle Adjustment Algorithm for Real-time High-Precision Image Georeferencing (실시간 고정밀 영상 지오레퍼런싱을 위한 고속 연속 번들 조정 알고리즘)

  • Choi, Kyoungah;Lee, Impyeong
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.2
    • /
    • pp.183-195
    • /
    • 2013
  • Real-time high-precision image georeferencing is important for the realization of image based precise navigation or sophisticated augmented reality. In general, high-precision image georeferencing can be achieved using the conventional simultaneous bundle adjustment algorithm, which can be performed only as post-processing due to its processing time. The recently proposed sequential bundle adjustment algorithm can rapidly produce the results of the similar accuracy and thus opens a possibility of real-time processing. However, since the processing time still increases linearly according to the number of images, if the number of images are too large, its real-time processing is not guaranteed. Based on this algorithm, we propose a modified fast algorithm, the processing time of which is maintained within a limit regardless of the number of images. Since the proposed algorithm considers only the existing images of high correlation with the newly acquired image, it can not only maintain the processing time but also produce accurate results. We applied the proposed algorithm to the images acquired with 1Hz. It is found that the processing time is about 0.02 seconds at the acquisition time of each image in average and the accuracy is about ${\pm}5$ cm on the ground point coordinates in comparison with the results of the conventional simultaneous bundle adjustment algorithm. If this algorithm is converged with a fast image matching algorithm of high reliability, it enables high precision real-time georeferencing of the moving images acquired from a smartphone or UAV by complementing the performance of position and attitude sensors mounted together.

CPW-fed Compact Slot Antenna Matched by T-shaped Stub (T형 스터브로 정합된 CPW급전 소형 슬롯 안테나)

  • Lee, Jong-Ig;Yeo, Jun-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.7
    • /
    • pp.3140-3145
    • /
    • 2012
  • In this paper, a design method for a compact slot antenna fed by a coplanar waveguide (CPW) is studied. A T-shaped tuning stub is inserted inside a narrow rectangular slot and the slot is impedance matched to the CPW feedline by adjusting the width, length, and position of the stub. The resonance frequency is adjustable by the slot length and the antenna size can be reduced by bending the slot. The resonance frequency and impedance matching property of the compact slot antenna are similar to those of the half-wavelength slot antenna, which enables one to design compact antenna of this type with ease. A compact slot antenna for 2.45-GHz ISM band is designed, fabricated on an FR4 substrate (dielectric constant of 4.4 and thickness of 0.8 mm), and experimentally tested. The measured results agree well with the simulations, which confirms the validity of this study. The fabricated compact slot antenna shows an impedance bandwidth of 200 MHz(2.32-2.52 GHz) for a VSWR < 2, which is suitable for 2.45-GHz ISM band (2.4-2.48 GHz). The measured radiation patterns show ${\infty}$-shaped directional pattern in the E-plane and nearly omni-directional pattern in the H-plane with a peak gain of 2.0 dBi, which are similar to those of a monopole antenna. The proposed antenna is expected to be suitable for the applications as antennas for WLAN, RFID, and mobile handset.

A Study on He Meng-Yao's(何夢瑤) Idea of Medicine of divination(醫易) (하몽요(何夢瑤)의 생애(生涯)와 의역사상(醫易思想)에 관(關)한 연구(硏究))

  • Yun, Chang-Yeol
    • Journal of Korean Medical classics
    • /
    • v.27 no.2
    • /
    • pp.109-117
    • /
    • 2014
  • Objectives : He Meng-Yao(何夢瑤), a doctor from Qing Dynasty, wrote Yi Bian(醫碥, Fundamentals of Medicine), in which he described many things related to Medical Medicine of divination (醫易). As the content includes a lot of teachings for the posterity, I have studied it. Methods : I have taken from Yi Bian(醫碥) the selections related to Medicine of divination(醫易) and explained them. Results : While accepting the principle of upholding yang and suppressing yin based on the understanding of the Book of Changes(周易) that takes a superior man for yang and a small man for yin, He Meng-Yao(何夢瑤), who thought of both yin and yang as Qi (energy), criticized the contemporary malpractice of uniformly applying the principle. In matching the five viscera to the Eight Trigrams(八卦), he put Qian and Dui Trigram(乾兌) to lung, Kan Trigram(坎卦) to kidney, Zhen and Xun Trigram(震巽) to liver, Li Trigram(離卦) to heart, and Kun and Gen Trigram(坤艮) to spleen, which is reasonable. He didn't fix the position of the vital gate and called it Fire in water(水中之火), and set great store by the role of Fire from Vital Gate(命門火) by calling it Water begetting tree(水生木) when the fire of the vital gate steams the kidney water and turns it into Qi to send it up to liver. He emphasized Water-ascending and Fire-descending(水升火降), which he said involves all five viscera. He also argued that mind runs on the principle of water-ascending and fire-descending. He thought that Qi and blood both originate from kidney, which I think is a significant suggestion. Conclusions : The criticism on the uniform application of upholding yang and suppressing yin, the combination of the five viscera and the Eight Trigrams(八卦), the belief that the Vital gate(命門) is Fire in water(水中之火), the excellent opinion on water-ascending and fire-descending, and the suggestion that Qi and blood both originate from kidney, as presented by He Meng-Yao(何夢瑤), are all theories that should be reasonably appreciated and further developed by the posterity.

Characteristics and Status of Commercial System for Utilizing MMS in Geospatial Information Construction (공간정보 구축 분야의 모바일 매핑 시스템 활용을 위한 상용 시스템의 특징 및 현황 조사)

  • Park, Joon-Kyu;Um, Dae-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.36-41
    • /
    • 2017
  • The mobile mapping system first introduced at Ohio State University in 1991 is being developed in various forms as sensor technology develops. The mobile mapping system can acquire geospatial information around amoving object quickly using the information gathered using the position and attitude information of the moving object and the data from various sensors. The mobile mapping system can rapidly acquire large amounts of Geospatial information and MMS provides maximum productivity in the same measurement methods as existing GNSS and total stations. Currently, a variety of systems are being launched, mainly by foreign companies, and they are applied to the construction of geospatial information. On the other hand, the application of domestic technology development or production is insufficient. This paper provides basic data for the introduction of a mobile mapping system to geospatial information related business by conducting the status survey and feature analysis of a commercialized system focusing on the ground-based mobile mapping system. The research identified the current status and characteristics of high-priced, low-priced, indoor, and handheld mobile mapping systems based on vehicles and suggest that the recent system development trends are moving toward lowering the unit prices. The mobile mapping system is currently being developed as a platform for the application of geospatial information construction and the launch of low-cost models. The development of data processing technologies, such as automatic matching and the launch of low-cost models, are forming a basis for the application of mobile mapping systems in the field of geospatial information construction.

A Study on Classification of Fish Oil Types and Its Usage by 13C-NMR Spectra and Fatty Acids Analysis (13C NMR 분석 및 지방산 분석을 통한 어유의 종류 구분 및 사용 실태에 관한 연구)

  • Cho, Eun-Ah;Lim, Sung-Jun;Oh, Tae-Heon;Ahn, Hyun-Joo;Yuk, Soo-Jin;Choi, Jin-Uk;Cha, Yun-Hwan;Lee, Young-Sang
    • The Korean Journal of Food And Nutrition
    • /
    • v.26 no.3
    • /
    • pp.352-357
    • /
    • 2013
  • This study estimates the classification criteria which distinguishes the types of omega-3 health functional foods, fish oils and fish oil usages through $^{13}C$-NMR spectra and fatty acids contents analysis. The major fatty acids of omega-3, eicosapentaenoic acid (EPA, $C_{20:5}$) and docosahexaenoic acid (DHA, $C_{22:6}$) are being analyzed. 10 ethyl ester (EE) forms and 10 triglyceride (TG) forms are the most common types of fish oils for 20 omega-3 products. Gas chromatography (GC) analysis generally shows the matching EPA and DHA contents of the products listed on the notation. But EE form contents of EPA and DHA are higher and are more varied than the TG form. Most of the samples of EPA/DHA ratio show different content ratios of indicated on the products when comparing with standards. The $^{13}C$-NMR analysis of EPA and DHA on sn-1,3 and sn-2 carbonyl peak position with fish oil triglycerides display whether the reconstituted triglycerides (rTG) are being confirmed or not. As a result of the 9 TG form, the 10 TG products showed similar values: EPA sn-1, 3; 13.46~15.66, sn-2; 3.00~4.52, DHA sn-1, 3; 2.43~4.40, sn-2; 3.84~6.36. But one product showed lower contents (EPA: sn-1, 3; 5.88, sn-2; 2.86, DHA sn-1, 3; 2.29, sn-2; 5.95) of EPA, thus it can be considered a different type of oil and only matched six products according to the label. This study is intended to provide basic materials which identify the status for the types and quality of omega-3 fish oil products according to fatty acids profiles and the $^{13}C$-NMR spectrum confirmed the location specificity of EPA and DHA.

Pattern Making Method and Design of Power Shoulder Jackets (파워 숄더 재킷의 디자인 및 패턴전개 방법)

  • Park, Sanghee;Lee, Eunhae
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.7
    • /
    • pp.131-140
    • /
    • 2013
  • Power shoulder look is most noticeable trend in women's wear in the 09/10 season. Specially jackets with sharper angle and wider shoulder became the best item since then, and were chosen for must-have item by fashion directors. Jacket occupied 50% in power shoulder items. Its shoulder angle was from 0 to 30 degree but items with 15 degree stood out among them. There are three methods to make power shoulder look jackets; shoulder extension method with moving shoulder tip up and sleeve cap height, method of extension and cutting sleeve cap with shorten shoulder length, and method of extension and moving shoulder tip up in the sleeve with shoulder line like raglan sleeve. As a result, shoulder angle is higher, starting point of shoulder line is closer to side neck point and shoulder point is extender to outside for appearance and fit. In shoulder extension method, the arm hole line was drawn with care by matching joining shoulder seam and setting the sleeve into the arm hole. In sleeve cap transformation, it is desired that starting point shoulder angle is moved closely to side neck point. In case of the sleeve with shoulder line, it needs to consider enough ease of shoulder and upper arm. For making patterns of power shoulder look jacket, it need to consider arm hole line, shoulder length, shoulder point position, sleeve cap height and sleeve width with interpretation design facts. In this study, through the analysis clothing construction method of power shoulder jacket, it is of help to pattern making for various power shoulder design items.