• Title/Summary/Keyword: Position matching

Search Result 472, Processing Time 0.027 seconds

Accuracy Estimation of Electro-optical Camera (EOC) on KOMPSAT-1

  • Park, Woon-Yong;Hong, Sun-Houn;Song, Youn-Kyung
    • Korean Journal of Geomatics
    • /
    • v.2 no.1
    • /
    • pp.47-55
    • /
    • 2002
  • Remote sensing is the science and art of obtaining information about an object, area or phenomenon through the analysis of data acquired by a device that is not in contact with the object, area, or phenomenon under investigation./sup 1)/ EOC (Electro -Optical Camera) sensor loaded on the KOMPSAT-1 (Korea Multi- Purpose Satellite-1) performs the earth remote sensing operation. EOC can get high-resolution images of ground distance 6.6m during photographing; it is possible to get a tilt image by tilting satellite body up to 45 degrees at maximum. Accordingly, the device developed in this study enables to obtain images by photographing one pair of tilt image for the same point from two different planes. KOMPSAT-1 aims to obtain a Korean map with a scale of 1:25,000 with high resolution. The KOMPSAT-1 developed automated feature extraction system based on stereo satellite image. It overcomes the limitations of sensor and difficulties associated with preprocessing quite effectively. In case of using 6, 7 and 9 ground control points, which are evenly spread in image, with 95% of reliability for horizontal and vertical position, 3-dimensional positioning was available with accuracy of 6.0752m and 9.8274m. Therefore, less than l0m of design accuracy in KOMPSAT-1 was achieved. Also the ground position error of ortho-image, with reliability of 95%, is 17.568m. And elevation error showing 36.82m was enhanced. The reason why elevation accuracy was not good compared with the positioning accuracy used stereo image was analyzed as a problem of image matching system. Ortho-image system is advantageous if accurate altitude and production of digital elevation model are desired. The Korean map drawn on a scale of 1: 25,000 by using the new technique of KOMPSAT-1 EOC image adopted in the present study produces accurate result compared to existing mapping techniques involving high costs with less efficiency.

  • PDF

A Study on Design and Interpretation of Pattern Laser Coordinate Tracking Method for Curved Screen Using Multiple Cameras (다중카메라를 이용한 곡면 스크린의 패턴 레이저 좌표 추적 방법 설계와 해석 연구)

  • Jo, Jinpyo;Kim, Jeongho;Jeong, Yongbae
    • Journal of Platform Technology
    • /
    • v.9 no.4
    • /
    • pp.60-70
    • /
    • 2021
  • This paper proposes a method capable of stably tracking the coordinates of a patterned laser image in a curved screen shooting system using two or more channels of multiple cameras. This method can track and acquire target points very effectively when applied to a multi-screen shooting method that can replace the HMD shooting method. Images of curved screens with severe deformation obtained from individual cameras are corrected through image normalization, image binarization, and noise removal. This corrected image is created and applied as an Euclidean space map that is easy to track the firing point based on the matching point. As a result of the experiment, the image coordinates of the pattern laser were stably extracted in the curved screen shooting system, and the error of the target point position of the real-world coordinate position and the broadband Euclidean map was minimized. The reliability of the proposed method was confirmed through the experiment.

A Bicentric Propensity Matched Analysis of 158 Patients Comparing Porcine Versus Bovine Stented Bioprosthetic Valves in Pulmonary Position

  • Bunty Ramchandani;Raul Sanchez;Juvenal Rey;Luz Polo;Alvaro Gonzalez;Maria-Jesus Lamas;Tomasa Centella;Jesus Diez;Angel Aroca
    • Korean Circulation Journal
    • /
    • v.52 no.8
    • /
    • pp.623-631
    • /
    • 2022
  • Background and Objectives: Pulmonary valve replacement (PVR) is the most common operation in adults with congenital heart disease (CHD). There is controversy regarding the best bioprosthesis. We compare the performance of stented bioprosthetic valves (the Mosaic [MedtronicTM] porcine pericardial against Carpentier Perimount Magna Ease [EdwardsTM] bovine) in pulmonary position in patients with CHD. Methods: Between January 1999 and December 2019, all the PVRs were identified from hospital databases in 2 congenital heart centres in Spain. Valve performance was evaluated using clinical and echocardiographic criteria. Propensity score matching was used to balance the 2 treatment groups. Results: Three hundred nineteen patients were retrospectively identified. After statistical adjustment, 79 propensity-matched pairs were available for comparison Freedom from reintervention for the porcine cohort was 98.3%, 96.1%, and 91.9% at 3, 5, and 10 years and 100%, 98%, and 90.8% for the bovine cohort (p=0.88). Freedom from structural valve degeneration (SVD) for the porcine cohort was 96.9%, 92.8% and 88.7% at 3, 5, and 10 years and 100%, 98%, and 79.1% for the bovine cohort (p=0.38). Bovine prosthesis was associated with a reintervention hazard ratio (HR), 1.12; 95% confidence intervals (CIs), 0.24-5.26; p=0.89 and SVD HR, 1.69 (0.52-5.58); p=0.38. In the first 5 years, there was no difference in outcomes. After 5 years, the recipients of the bovine bioprosthesis were at higher risk for SVD (reintervention HR, 2.08 [0.27-16.0]; p=0.49; SVD HR, 6.99 [1.23-39.8]; p=0.03). Conclusions: Both bioprosthesis have similar outcomes up to 5 years, afterwards, porcine bioprosthesis seem to have less SVD.

Evaluation of the usefulness of IGRT(Image Guided Radiation Therapy) for markerless patients using SGPS(Surface-Guided Patient Setup) (표면유도환자셋업(Surface-Guided Patient Setup, SGPS)을 활용한 Markerless환자의 영상유도방사선치료(Image Guided Radiation Therapy, IGRT)시 유용성 평가)

  • Lee, Kyeong-jae;Lee, Eung-man;Lee, Jeong-su;Kim, Da-yeon;Ko, Hyeon-jun;Choi, Shin-cheol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.109-116
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the usefulness of Surface-Guided Patient Setup by comparing the patient positioning accuracy when image-guided radiation therapy was used for Markerless patients(unmarked on the skin) using Surface-Guided Patient Setup and Marker patients(marked on the skin) using Laser-Based Patient Setup. Materials And Methods: The position error during IGRT was compared between a Markerless patient initially set up with SGPS using an optical surface scanning system using three cameras and a Marker patient initially set up with LBPS that aligns the laser with the marker drawn on the patient's skin. Both SGPS and LBPS were performed on 20 prostate cancer patients and 10 Stereotactic Radiation Surgery patients, respectively, and SGPS was performed on an additional 60 breast cancer patients. All were performed IGRT using CBCT or OBI. Position error of 6 degrees of freedom was obtained using Auto-Matching System, and comparison and analysis were performed using Offline-Review in the treatment planning system. Result: The difference between the root mean square (RMS) of SGPS and LBPS in prostate cancer patients was Vrt -0.02cm, Log -0.02cm, Lat 0.01cm, Pit -0.01°, Rol -0.01°, Rtn -0.01°, SRS patients was Vrt 0.02cm, Log -0.05cm, Lat 0.00cm, Pit -0.30°, Rol -0.15°, Rtn -0.33°. there was no significant difference between the two regions. According to the IGRT standard of breast cancer patients, RMS was Vrt 0.26, Log 0.21, Lat 0.15, Pit 0.81, Rol 0.49, Rtn 0.59. Conclusion:. As a result of this study, the position error value of SGPS compared to LBPS did not show a significant difference between prostate cancer patients and SRS patients. In the case of additionally performed SGPS breast cancer patients, the position error value was not large based on IGRT. Therefore, it is considered that it will be useful to replace LBPS with SGPS, which has the great advantage of not requiring patient skin marking..

Evaluation of Target Position's Accuracy in 2D-3D Matching using Rando Phantom (인체팬톰을 이용한 2D-3D 정합시 타켓위치의 정확성 평가)

  • Jang, Eun-Sung;Kang, Soo-Man;Lee, Chul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.33-39
    • /
    • 2009
  • Purpose: The aim of this study is to compare patient's body posture and its position at the time of simulation with one at the treatment room using On-board Imaging (OBI) and CT (CBCT). The detected offsets are compared with position errors of Rando Phantom that are practically applied. After that, Rando Phantom's position is selected by moving couch based on detected deviations. In addition, the errors between real measured values of Rando Phantom position and theoretical ones is compared. And we will evaluate target position's accuracy of KV X-ray imaging's 2D and CBCT's 3D one. Materials and Methods: Using the Rando Phantom (Alderson Research Laboratories Inc. Stanford. CT, USA) which simulated human body's internal structure, we will set up Rando Phantom on the treatment couch after implementing simulation and RTP according to the same ways as the real radioactive treatment. We tested Rando Phantom that are assumed to have accurate position with different 3 methods. We measured setup errors on the axis of X, Y and Z, and got mean standard deviation errors by repeating tests 10 times on each tests. Results: The difference between mean detection error and standard deviation are as follows; lateral 0.4+/-0.3 mm, longitudinal 0.6+/-0.5 mm, vertical 0.4+/-0.2 mm which all within 0~10 mm. The couch shift variable after positioning that are comparable to residual errors are 0.3+/-0.1, 0.5+/-0.1, and 0.3+/-0.1 mm. The mean detection errors by longitudinal shift between 20~40 mm are 0.4+/-0.3 in lateral, 0.6+/-0.5 in longitudinal, 0.5+/-0.3 in vertical direction. The detection errors are all within range of 0.3~0.5 mm. Residual errors are within 0.2~0.5 mm. Each values are mean values based on 3 tests. Conclusion: Phantom is based on treatment couch shift and error within the average 5mm can be gained by the diminution detected by image registration based on OBI and CBCT. Therefore, the selection of target position which depends on OBI and CBCT could be considered as useful.

  • PDF

Design of wide-band slot loop antenna by using dual offset-fed (이중 오프셋 급전을 이용한 광대역 슬롯 루프 안테나의 설계)

  • 조영빈;나종덕;전계석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.11A
    • /
    • pp.912-920
    • /
    • 2003
  • This paper is about the design of a small wide-band slot loop antenna, which consists of dual offset-fed and rectangular loop within the slot on a substrate. The proposed antenna is a novel structure generating a multi-resonances due to three geometrical resonance structures. The impedance matching of this antenna can be accomplished by changing the offset position of dual-fed at resonance frequencies. In this experiment, the slot of a fabricated antenna has a center frequency of 6.755㎓, 12.5mm${\times}$50mm in size and the rectangular loop has 10.5mm${\times}$27.5mm in size. The measured result is fractional bandwidth 63.21% with VSWR 2:1, which is agreed with the simulated result within 5% of error, and the maximum antenna gain is 7.42㏈i.

Stereo Vision-based Visual Odometry Using Robust Visual Feature in Dynamic Environment (동적 환경에서 강인한 영상특징을 이용한 스테레오 비전 기반의 비주얼 오도메트리)

  • Jung, Sang-Jun;Song, Jae-Bok;Kang, Sin-Cheon
    • The Journal of Korea Robotics Society
    • /
    • v.3 no.4
    • /
    • pp.263-269
    • /
    • 2008
  • Visual odometry is a popular approach to estimating robot motion using a monocular or stereo camera. This paper proposes a novel visual odometry scheme using a stereo camera for robust estimation of a 6 DOF motion in the dynamic environment. The false results of feature matching and the uncertainty of depth information provided by the camera can generate the outliers which deteriorate the estimation. The outliers are removed by analyzing the magnitude histogram of the motion vector of the corresponding features and the RANSAC algorithm. The features extracted from a dynamic object such as a human also makes the motion estimation inaccurate. To eliminate the effect of a dynamic object, several candidates of dynamic objects are generated by clustering the 3D position of features and each candidate is checked based on the standard deviation of features on whether it is a real dynamic object or not. The accuracy and practicality of the proposed scheme are verified by several experiments and comparisons with both IMU and wheel-based odometry. It is shown that the proposed scheme works well when wheel slip occurs or dynamic objects exist.

  • PDF

Detection of Face Direction by Using Inter-Frame Difference

  • Jang, Bongseog;Bae, Sang-Hyun
    • Journal of Integrative Natural Science
    • /
    • v.9 no.2
    • /
    • pp.155-160
    • /
    • 2016
  • Applying image processing techniques to education, the face of the learner is photographed, and expression and movement are detected from video, and the system which estimates degree of concentration of the learner is developed. For one learner, the measuring system is designed in terms of estimating a degree of concentration from direction of line of learner's sight and condition of the eye. In case of multiple learners, it must need to measure each concentration level of all learners in the classroom. But it is inefficient because one camera per each learner is required. In this paper, position in the face region is estimated from video which photographs the learner in the class by the difference between frames within the motion direction. And the system which detects the face direction by the face part detection by template matching is proposed. From the result of the difference between frames in the first image of the video, frontal face detection by Viola-Jones method is performed. Also the direction of the motion which arose in the face region is estimated with the migration length and the face region is tracked. Then the face parts are detected to tracking. Finally, the direction of the face is estimated from the result of face tracking and face parts detection.

A PANORAMIC VIEW OF THE ASTEROIDS IN THE INNER SOLAR SYSTEM WITH AKARI

  • Usui, F.;Kuroda, D.;Muller, T.G.;Hasegawa, S.;Ishiguro, M.;Ootsubo, T.;Ueno, M.;AKARI SOSOS team, AKARI SOSOS team
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.153-159
    • /
    • 2012
  • We constructed an unbiased asteroid catalog from the mid-infrared part of the All-Sky Survey with the Infrared Camera (IRC) on board AKARI. About 20% of the point source events recorded in the IRC All-Sky Survey observations were not used for the IRC Point Source Catalog in its production process because of a lack of multiple detection by position. Asteroids, which are moving objects on the celestial sphere, are included in these "residual events" We identified asteroids out of the residual events by matching them with the positions of known asteroids. For the identified asteroids, we calculated the size and albedo based on the Standard Thermal Model. Finally we had a new brand of asteroid catalog, which contains 5,120 objects, about twice as many as the IRAS asteroid catalog.

EKF SLAM-based Camera Tracking Method by Establishing the Reference Planes (기준 평면의 설정에 의한 확장 칼만 필터 SLAM 기반 카메라 추적 방법)

  • Nam, Bo-Dam;Hong, Hyun-Ki
    • Journal of Korea Game Society
    • /
    • v.12 no.3
    • /
    • pp.87-96
    • /
    • 2012
  • This paper presents a novel EKF(Extended Kalman Filter) based SLAM(Simultaneous Localization And Mapping) system for stable camera tracking and re-localization. The obtained 3D points by SLAM are triangulated using Delaunay triangulation to establish a reference plane, and features are described by BRISK(Binary Robust Invariant Scalable Keypoints). The proposed method estimates the camera parameters from the homography of the reference plane when the tracking errors of EKF SLAM are much accumulated. Using the robust descriptors over sequence enables us to re-localize the camera position for matching over sequence even though the camera is moved abruptly.