• Title/Summary/Keyword: Position index

Search Result 798, Processing Time 0.024 seconds

Which is the proper insertion method of laryngeal mask airway according to the rescuer's position? : Comparison between index finger insertion and thumb insertion (구조자의 위치에 따른 적절한 후두마스크기도기 삽입방법은 무엇일까? : 검지손가락법과 엄지손가락법의 비교)

  • Chun, Kyoung-Ha;Moon, Jun-Dong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.21 no.3
    • /
    • pp.7-16
    • /
    • 2017
  • Purpose: The purpose of the study was to investigate the effects of laryngeal mask airway (LMA) insertion from different positions, using different methods, on the quality of the insertion, for identifying a more convenient and effective insertion method. Methods: In a model ambulance, 30 paramedic students performed the LMA insertion procedure, in four different settings, combinations of the rescuer's position (at the head end of the patient, at the side of the patient), and insertion technique (index finger insertion, thumb insertion), in a randomized order. Quality of insertion index and convenience of use were measured. Results: The quality of insertion index (tidal volume, gastric insufflation, airway pressure, airway sealing pressure, midline positions, insertion success grade, and insertion time) were not significantly different among four different settings. However LMA insertion from the anterior (head) end, using the index finger method compared to the thumb method was found to be significantly more convenient. Conclusion: We recommend using the more convenient and familiar LMA insertion method, between index finger insertion and thumb insertion, regardless of rescuer's position.

A Performance Index for Time Slot Allocation in Link-16 Relative Navigation System

  • Lee, Jin Hyuk;Lee, Ju Hyun;Noh, Jae Hee;Lim, Deok Won;Park, Chansik;Lee, Sang Jeong
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.6 no.3
    • /
    • pp.117-123
    • /
    • 2017
  • In this paper, we propose a performance index that can compare the position estimation performance according to the time slot allocation order, which is superior in the position estimation performance in the operation of the Link-16 based relative navigation system. In order to verify the validity of the performance index, a software-based Link-16 relative navigation system performance analysis platform composed of a signal generator, a signal reception and navigation algorithm execution unit, and a performance analysis unit was designed. Using the designed software platform, we analyzed the relationship between proposed performance index and position estimation performance according to time slot allocation order in the same position reference (PR) arrangement. The performance index of the proposed time slot allocation is expected to be utilized not only for the Link-16 system, but also for the Time Division Multiple Access (TDMA)-based navigation system.

A Space Partitioning Based Indexing Scheme Considering, the Mobility of Moving Objects (이동 객체의 이동성을 고려한 공간 분할 색인 기법)

  • Bok, Kyoung-Soo;Yoo, Jae-Soo
    • Journal of KIISE:Databases
    • /
    • v.33 no.5
    • /
    • pp.495-512
    • /
    • 2006
  • Recently, researches on a future position prediction of moving objects have been progressed as the importance of the future position retrieval increases. New index structures are required to efficiently retrieve the consecutive positions of moving objects. Existing index structures significantly degrade the search performance of the moving objects because the search operation makes the unnecessary extension of the node in the index structure. To solve this problem, we propose a space partition based index structure considering the mobility of moving objects. To deal with the overflow of a node, our index structure first merges it and the sibling node. If it is impossible to merge them, our method splits the overflow node in which moving properties of objects are considered. Our index structure is always partitioned into overlap free subregions when a node is split. Our split strategy chooses the split position by considering the parameters such as velocities, the escape time of the objects, and the update time of a node. In the internal node, the split position Is determined from preventing the cascading split of the child node. We perform various experiments to show that our index structure outperforms the existing index structures in terms of retrieval performance. Our experimental results show that our proposed index structure achieves about $17%{\sim}264%$ performance gains on current position retrieval and about $107%{\sim}19l%$ on future position retrieval over the existing methods.

Decision of Modulation Index of Current-Source TPWM Inverter for Minimization of Speed Ripple and Position Error (속도맥동 및 위치오차를 최소로 하는 전류원 TPWM 인버터의 변조도 결정)

  • 구본호;권우현;김수중
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.11
    • /
    • pp.1819-1828
    • /
    • 1989
  • In this paper, we determined the modulation index for minimization of speed ripple and position error using maximum speed ripple (SRF) and maximum position error(PEF) in current source TPWM inverter. Through computer simulation, we compared with total current harmonic distortion, SRF and PEF for square wave modulation method and TPWM method. As a result, it turns out that square wave modulation method is superior to TPWM method of 3 pulses per half cycle in speed ripple and position error contents. And TPWM is better than square wave method when pulse number is more than 5. Also, in these pulse numbers, moduladtion index of minimum speed ripple and munimum position error is 0.91.

  • PDF

The Effect of Body Positioning on Physiologic Index in Patients with Unilateral Lung Disease (편측성 폐질환 환자의 체위변경이 생리적 지표에 미치는 영향)

  • Cho, Jee Yeon;Lee, Hyang Yeon
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.1
    • /
    • pp.122-133
    • /
    • 2000
  • The purpose of this study was to identify the effect of body positioning on $PaO_2$, $SpO_2$, systolic blood pressure, diastolic blood pressure, pulse, and respiration(above all defined physiologic index), of patients with unilateral lung disease. The subjects for this study were eleven patients admitted to I.C.U. of K.H.M.C. with a diagnosis of unilateral lung disease confirmed by chest X-ray and the attending doctor, from January 30th. to April 20th. 1999. A quasi-experimental repeated-measures cross-over design was used to compare three body positions(semi-Fowler's, lateral decubitus with good lung dependent, and lateral decubitus with diseased lung dependent). Each subject spent 30 minutes in semi-Fowler's position and 2 hours in good lung dependent position and diseased lung dependent position. Starting in the semi-Fowler's position, then in the lateral position with the good lung dependent or the diseased lung dependent as assigned in random order. Thirty minutes after each positioning, arterial blood sample was analyzed. Measurements of all physiologic index were recorded at the specified intervals(0, 30, 60 90, and 120 minutes) in good lung dependent and diseased lung dependent position. Statistical comparison of $PaO_2$ value was done using the Wilcoxon Signed Rank Test, and Multivariate repeated-measures analysis of variance was performed to analyse the within-subject effect of two dependent position for 2 hours on the five dependent variables: (1) $PaO_2$ (2) $SpO_2$ (3) systolic blood pressure (4) diastolic blood pressure (5) pulse. The results obtained were as follows: 1. The $PaO_2$ value in the good lung dependent position was significantly higher than the $PaO_2$ value in the diseased lung dependent position(Z=-2.8451, p=.002). 2. The $PaO_2$ value in the good lung dependent position was significantly higher than the $PaO_2$ value in the semi-Fowler's position (Z=-2.6673, p=.003). 3. The difference between the $PaO_2$ value in the semi-Fowler's position and the $PaO_2$ value in the diseased lung dependent position was not significant(Z=-1.2448, p=.10). 4. There were no statistically significance in the trends of physiologic index in the good lung dependent position and the diseased lung dependent position. From the results, it may be concluded that the good lung dependent position is the most effective position for patients with unilateral lung disease that improve oxygenation. Identification of positioning over time may be need further studies.

  • PDF

SECOND MAIN THEOREM FOR MEROMORPHIC MAPPINGS ON p-PARABOLIC MANIFOLDS INTERSECTING HYPERSURFACES IN SUBGENERAL POSITION

  • Yuehuan Zhu
    • Bulletin of the Korean Mathematical Society
    • /
    • v.60 no.6
    • /
    • pp.1621-1639
    • /
    • 2023
  • In this paper, we give an improvement for the second main theorems of algebraically non-degenerate meromorphic maps from generalized p-parabolic manifolds into projective varieties intersecting hypersurfaces in subgeneral position with some index, which extends the results of Han [6] and Chen-Thin [3].

Indexing Moving Objects with Real-Time Updates (실시간 갱신을 통한 이동 객체의 색인 기법)

  • Bok Kyoung-Soo;Seo Dong-Min;Yoo Jae-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.4 no.4
    • /
    • pp.141-152
    • /
    • 2004
  • In this paper, we propose the index structure supporting the future position retrievals with efficiently updating continuous positions of moving objects in location based services. For reducing update costs of moving objects, our index structure directly accesses to the leaf node with moving objects using secondary index structure and performs bottom up update when node information is changed. Positions of moving objects are stored in primary index structure. In primary index structure, the split information similar to kd-tree is stored to internal node for increasing node's fanout. And the proposed index structure supports the future position retrievals using velocity of moving objects in the child node.

  • PDF

Application of Normality Test and Classification of Process Capability Index (공정능력지수의 유형화 및 정규성 검정의 응용)

  • Choe, Seong-Un
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.11a
    • /
    • pp.551-556
    • /
    • 2011
  • This research presents an implementation strategy of Process Capability Index (PCI) according to the types of process characteristics. The types of process feature are classified as four perspectives of variation range, time period, error position, and process stage. The paper examines short-term or long-term PCI, within or between variation, position of precision or accuracy, and inclusion of measurement or calibration stage. Moreover, the study proposes normality test of unilateral PCI.

  • PDF

A Statistical Analysis Method for Image Processing Errors in the Position Alignment of BGA-type Semiconductor Packages (BGA형 반도체 패키지의 위치정렬용 영상처리기법 오차의 통계적 분석 방법)

  • Kim, Hak-Man;Seong, Sang Man;Kang, Kiho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.11
    • /
    • pp.984-990
    • /
    • 2013
  • Pick and placement systems need high speeds and reliability for the position alignment process of semiconductor packages in picking up and placing them on placement trays. Image processing is usually adopted for position aligning where finding out the most suitable method is considered most important aspect of the process. This paper proposes a method for judging the performance of different image processing algorithms based on the PCI (Process Capability Index). The PCI is an index which represents the error distribution acquired from many experimental data. The bigger the index, the more reliable the results or the lower the deviation. Two compared and candidate methods are Hough Transform and PCA (Principal Component Analysis), both of which are very suitable for oblong or rectangular type packages such as BGA's. Comparing the two approaches through a CPI with enough experimental results leads to the conclusion that the PCA is much better than the Hough Transform in not only reliability, but also processing speed.

The Change of Curvature and Intervertebral Disc Angle of Cervical Spine in Prone Position for Acupuncture (복와위 자침 자세에 따른 경추 만곡과 추간판 각도의 변화)

  • Hyeonsun Park;Dongho Keum
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.34 no.3
    • /
    • pp.75-88
    • /
    • 2024
  • Objectives This study was designed to compare curvature and intervertebral disc angle of the cervical spine in different prone positions. Methods 30 adults aged 19~60 years were enrolled in this study. Volunteers in this uncontrolled trial were taken an x-ray of cervical spine on lateral. Four radiographs were taken for each volunteer, in standing, prone position with U-type pillow (prone position A), rectangular pillow (prone position B), and prone position without pillow (prone position C). After measuring the cervical angle, Ishihara index, craniovertebral angle, intervertebral angle, we analysed the lordotic angle and foward head posture. The data was anlysed by analysis of variance and pearson correlation coefficient. Results Cervical angles of prone position without pillow (prone position C) significantly decreased compared with those in standing position (p<0.001). Ishihara index of prone position without pillow (prone position C) also significantly decreased compared with those in standing position (p<0.001). Craniovertebral angle of prone position with pillow (prone position A, B) significantly increased with those in standing position (p<0.001). Intervertebral angle of prone position with pillow (prone position A, B) at the C3-7 levels significantly increased with those in standing position (p<0.001). Intervertebral angle of prone position without pillow (prone position C) at the C3-5 levels significantly decreased with those in standing position (p<0.001). The angle of intervertebral disc significntly decreased in kyphotic cervical levels. Conclusions Different prone position clearly resulted changes in cervical spine curvature and intervertebral disc angle. And it is related to cervical spine lordotic angle and sagittal alignment in standing position and prone position.